INST AL L AT I ON M AN U A L 6.2.2 Wireless The wireless connection is divided into 2 types: Connection via a ‘modbus’ protocol. Control via an application. !Caution Only 1 type of wireless connection is possible on the communication module. English 6.2.2.1 Connection via ‘modbus’ protocol Wireless connection of a Domotics system to the receiver is possible via a connection according to the ‘modbus’ protocol. Such a connection can only be established with a communication module (see Appendix 3, fig. 35 (W)). This module can be ordered from DRU. This communication module translates the ‘modbus’ protocol from the Domotics system into a wireless signal to the receiver. Ø Ø Ø Ø Ø When connecting a Domotics system via the communication module to the receiver, proceed as follows: Using the remote control, test whether the location where you want to place the communication module is within the receiver's range. Place the remote control on this location and test the reception sensitivity (RSSI). Press the on/off button and down arrow at the same time. The value that is now visible, must be between -20 and -70 (see User Manual, "Reception Sensitivity"). If needed, hold the remote control closer to the appliance in order to improve the reception. Connect the communication module by means of an RJ45 plug, according to the instructions in the manual that is supplied with this module. Now follow the steps described in the ‘modbus’ protocol manual. It is available from the supplier of the domotics system. 6.2.2.2 Control via application If the fire is operated via a tablet using the application (iOS or Android), a communication module is required. This module can be ordered from DRU. Ø Ø Ø Ø Ø In order to control the fire via an application, proceed as follows: Using the remote control, test whether the location where you want to place the communication module is within the receiver's range. Place the remote control on this location and test the reception sensitivity (RSSI). Press the on/off button and down arrow at the same time. The value that is now visible, must be between -20 and -70 (see User Manual, "Reception Sensitivity"). If needed, hold the remote control closer to the appliance in order to improve the reception. Connect the communication module by means of an RJ45 plug, according to the instructions in the manual that is supplied with the communication module. Use the instructions for the application in order to install it. The application 'DRU Control' is available in the AppStore, at GooglePlay or our website: www.drufire.co.uk 7. Final inspection In order to check whether the appliance is working properly and safely, you must perform the following inspections before the appliance is put into operation. 7.1 Gastightness !Caution All connections must be gastight. Check the connections for gastightness. The gas control may be subjected to a maximum pressure of 50 mbar. 7.2 Gas pressure/line-pressure The burner pressure is set at the factory; see data plate. !Caution The line-pressure in house installations must be checked, because it can be wrong. Ø Ø Check the line-pressure; see Appendix 3, Fig 38 (P1) for the measuring nipple on the gas control. Contact the gas company if the line-pressure is not correct. UK