Common Firmware Environment (CFE) Functional Specification
8.5.4 CFE_CMD_FW_GETTIME
Obtain system time and call internal polling functions. This routine can be used to obtain CFE’s
idea of the system time (see the timer manager for details). It also causes the internal device
polling routines to be run, so boot loaders should periodically call this service to ensure that
network timeouts occur and packets are processed.
Request structure fields:
xiocb field
xiocb_fcode
xiocb_status
xiocb_handle
xiocb_flags
xiocb_psize
Description
4 (CFE_CMD_FW_GETTIME)
0
0
0
sizeof(xiocb_time_t)
Return structure fields:
xiocb field
plist:ticks
Description
Current system time in ticks (units of CFE_HZ)
Error codes:
Code
none
Description
none