Download X - Yaskawa
Transcript
Wiring Main Circuit Terminals Applicable Wire Sizes and Closed-loop Connectors Select the appropriate wires and crimp terminals from Table 2.1 to Table 2.2. Table 2.1 208-240Vac Wire Sizes and Connector Specifications Drive Model CIMR-E7U Nominal Hp 0.5/0.75 R/L1, S/L2, T/L3, , 1, B1, B2, U/T1, V/T2, W/T3 2, 20P4 2 R/L1, S/L2, T/L3, , 1, B1, B2, U/T1, V/T2, W/T3 2, 20P7 1.5/2 R/L1, S/L2, T/L3, , 1, B1, B2, U/T1, V/T2, W/T3 2, 21P5 3 R/L1, S/L2, T/L3, , 1, B1, B2, U/T1, V/T2, W/T3 2, 22P2 5 R/L1, S/L2, T/L3, , 1, B1, B2, U/T1, V/T2, W/T3 2, 23P7 7.5 R/L1, S/L2, T/L3, , 1, B1, B2, U/T1, V/T2, W/T3 2, 25P5 10 R/L1, S/L2, T/L3, , 1, B1, B2, U/T1, V/T2, W/T3 2, 27P5 2011 15 Terminal Symbol R/L1, S/L2, T/L3, , 1, B1, B2, U/T1, V/T2, W/T3 R/L1, S/L2, T/L3, 2015 20 25 1, , 1, 2, U/T1, V/T2, W/T3 2, U/T1, V/T2, W/T3 B1, B2 R/L1, S/L2, T/L3, , 1, U/T1, V/T2, W/T3, R1/L11, S1/L21, T1/L31 2022 30 3 R/L1, S/L2, T/L3, , 1 U/T1, V/T2, W/T3, R1/L11, S1/L21, T1/L31 2030 40 3 Clamping Torque lb. in. (N•m) Recommended Wire Size AWG (mm2) M4 13.3 (1.5) 14 (2.1) M4 13.3 (1.5) 14 (2.1) M4 13.3 (1.5) 14 (2.1) M4 13.3 (1.5) 12 (3.3) M4 13.3 (1.5) 10 (5.3) M4 13.3 (1.5) 10 (5.3) M5 22.1 (2.5) 8 (8) M5 22.1 (2.5) 6 (13.3) M6 44.3 (5.0) 4 (21.2) M5 22.1 (2.5) 6 (13.3) M6 44.3 (5.0) 6 (13.3) M8 88.5 (10.0) 2 (33.6) M5 22.1 (2.5) 6 (13.3) M6 44.3 (5.0) 4 (21.2) M8 88.5 (10.0) 1 (42.4) M6 45.1 (5.1) 4 (21.2) M8 88.5 (10.0) 4 (21.2) M8 88.5 (10.0) 1/0 (53.5) M6 45.1 (5.1) 4 (21.2) M8 88.5 (10.0) 2 (38) 2, B1, B2 R/L1, S/L2, T/L3, 2018 , Terminal Screws Electrical Installation 2 - 3 Wire Type 600Vac UL Approved vinyl-sheathed or equivalent