Download ENDA EPA741 PROGRAMMABLE AC/DC AMMETER
Transcript
Read this document carefully before using this device. The guarantee will be expired by damaging of the device if you don't attend to the directions in the user manual. Also we don't accept any compensations for personal injury, material damage or capital disadvantages. ENDA EPA741 PROGRAMMABLE AC/DC AMMETER Thank you for choosing ENDA EPA741 programmable AC/DC ammeter. * 72 x 72mm sized. * 4 digits display. * Easy to use by front panel keypad. * With current trafo or shunt can be used. * Programmable scale between 5A and 9999A. * Multifunctional alarm output (NO+NC) for upper and lower limits. * CE marked according to Europan Norms. * Measuring type can be selected AC, DC or True RMS EPA 741 OUT AC DC AC/DC SET Order Code : EPA741 - - 1 2 3 3 - Supply Voltage 1 - Input Type 2 - Output 230VAC...230V AC S.........Internal Shunt Resistor R.........Relay 24VAC.....24V AC None...External Shunt Resistor None...No Relay SSR....Logic output SM...........9-30V DC / 7-24V AC ENDA PROGRAMMABLE AC/DC AMMETER TECHNICAL SPECIFICATIONS ENVIRONMENTAL CONDITIONS Ambient/stroge temperature 0 ... +50°C/-25 ... 70°C 80% up to 31°C decreasing linearly 50% at 40°C. Max. Relative humidity Rated pollution degree According to EN 60529 Height Max. 2000m Front panel : IP65 , Rear panel : IP20 Do not use the device in locations subject to corrosive and flammable gases. ELECTRICAL CHARACTERISTICS Supply Power consumption Wiring Scale Sensitivity Accuracy 230V AC +10% -20%, 50/60Hz or 24V AC ±10% , 50/60Hz or optional 9-30V DC / 7-24V AC ±10% SMPS Max. 7VA 2.5mm² screw-terminal connections 0A...9999A (Specified c.tr.r parameter. For example:scale is 0A...5A for c.tr.r=5.00) AC and RMS -999A...9999A (Specified c.tr.r parameter. For example:scale is -5A...5A for c.tr.r=5.00) DC 0.002A x c.tr.r ( For example , 0.01A for c.tr.r=5.00 ) ± 1% (full scale) (For square wave form ± 2%) AC ± 1% (full scale) DC ± 1% RMS (full scale) (For square wave form ± 2%) Input Range EPA741Sxx EPA741xx Input Impedance EPA741Sxx 12mÙ 40kÙ EPA141xx DC , 10Hz - 200Hz (For square wave form 10Hz-70Hz) Frequency Range EMC Safety requirements -5A...5A (Device damages 10A peak and more current.) -60mV...60mV (Device damages 50V peak and more voltage.) EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B for the EMC standard) EN 61010-1: 2001 (Pollution degree 2, overvoltage category II) OUTPUTS Alarm output Life expectancy for relay Relay: 250V AC, 8A (for resistive load), NO+NC or 12V DC 20mA logic output. Mechanical 30.000.000 ; Electrical 100.000 operation. HOUSING Housing type Dimensions Suitable for flush-panel mounting. (According to DIN 43 700) Weight EPA741 EPA741-24 Enclosure material Self extinguishing plastics. W72xH72xD97mm Approx. 350g (after packing) Approx. 350g (after packing) While cleaning the device, solvents (thinner, benzine, acid etc.) or corrosive materials must not be used. SÝSEL MÜHENDÝSLÝK ELEKTRONÝK SAN. VE TÝC. A.Þ. Yukarý Dudullu Barbaros Cad. Kutup Sok. No:20 34775 - ÜMRANÝYE/ÝSTANBUL/TÜRKÝYE Tel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01 url : www.enda.com.tr 1/3 EPA741-E-07-R DIMENSIONS Depth Panel cut-out 97mm 75mm 2 EPA 741 +0.7 AC DC UP.l1 + HYS.U UP.l1 UP.l1 - HYS.U AC/DC +0.7 OUT mm mm 78mm 72mm 68 Input LO.l1 + HYS.U 68 SET LO.l1 LO.l1 - HYS.U PROGRAMMABLE AC/DC AMMETER 84mm ENDA t dly.U Out Connection cables dly.U dly.l dly.l A.out = n.o. t 1 1 Out For removing mounting clamps: - Push the flush-mounting clamp in direction 1 as shown in the figure left. - Then, pull out the clamp in direction 2. 2 A.out = n.c. t Equipment is protected throughout by DOUBLE INSULATION Flush mounting clamp ac Holding screw 0.4-0.5Nm. Panel dc Ac.dc (rms) A Note 1) While panel mounting, additional distance required for connection cables should be considered. 2) Panel thickness should be maximum 10mm. 3) If there is no 90mm free space at back side of the device, it would be difficult to remove it from the panel. Rubber packing CONNECTION DIAGRAM 0 T/2 3T/2 T A 1 2 2T 0.000 A 1 2 -A A ENDA EPA741 is intended for installation in control panels.Make sure that the device is used only for intended purpose.The electrical connections must be carried on by a qualified staff and must be according to the relevant locally applicable regulations. During an installation, all of the cables that are connected to the device must be free of energy. The device must be protected against inadmissible humidity, vibrations, severe soiling and make sure that the operation temperature is not exceeded. The cables should not be close to the power cables or components. 0 T/2 T 3T/2 T/2 T 3T/2 0.308 A A 2 A 1 2 0.386 A A1 A 1 2 A 0.000 A A 1 2 A 1 2 A 1 2 2T p A 0 p A NOTE : Fuse F 100mA 250V AC SUPPLY: 184-253V AC 14 50/60Hz 7VA 15 Line + Fuse should be connected. Switch 230V AC Supply 15 19 SN: XXXXXXXXX INDUSTRIAL ELECTRONICS EPA741-SSR-230VAC PROGRAMMABLE AC/DC AMMETER 11 14 19 20 ENDA 14 230V AC +10% -20% 50/60Hz 7VA 15 SN: XXXXXXXXX INDUSTRIAL ELECTRONICS EPA741S-R-230VAC PROGRAMMABLE AC/DC AMMETER + 19 3T/2 T 2T SN: XXXXXXXXX INDUSTRIAL ELECTRONICS EPA741S-SSR-230VAC PROGRAMMABLE AC/DC AMMETER A SN: XXXXXXXXX INDUSTRIAL ELECTRONICS EPA741S-R-24VAC PROGRAMMABLE AC/DC AMMETER + 19 Max. 5A AC / DC 20 ENDA SN: XXXXXXXXX INDUSTRIAL ELECTRONICS EPA741S-230VAC PROGRAMMABLE AC/DC AMMETER 19 CAT II Max. 60mV AC / DC + ENDA SN: XXXXXXXXX INDUSTRIAL ELECTRONICS EPA741-S-24VAC PROGRAMMABLE AC/DC AMMETER 19 ENDA SN: XXXXXXXXX INDUSTRIAL ELECTRONICS EPA741-230VAC PROGRAMMABLE AC/DC AMMETER 2/3 d2 2 T A d T A d T A Max. 60mV AC / DC + 19 20 20 20 2T T d T 15 15 CAT II + d d 14 24V AC +10% 50/60Hz 7VA 230V AC +10% -20% 50/60Hz 7VA 15 CAT II Max. 5A AC / DC 20 ENDA T/2 ENDA 14 14 24V AC +10% 50/60Hz 7VA 15 CAT II Max. 5A AC / DC 0 0 CAT II + 20 A 14 24V AC +10% 50/60Hz 7VA 15 A 19 13 CAT II 2T 12 13 Max. 5A AC / DC + 11 OUTPUT 250V AC 8A RESISTIVE LOAD 12 230V AC +10% -20% 50/60Hz 7VA Max. 5mA AC / DC 20 ENDA OUTPUT 250V AC 8A RESISTIVE LOAD 15 CAT II + 3T/2 13 230V AC +10% -20% 50/60Hz 7VA CAT II Max. 60mV AC / DC T T/2 14 14 230V AC +10% -20% 50/60Hz 7VA 0 -A _ 13 Cable size: 1,5mm² 1) Mains supply cords shall meet the requirements of IEC 60227 or IEC 60245. 2) In accordance with the safety regulations, the power supply switch shall bring the identification of the relevant instrument and it should be easily accessible by the operator. 11 LOGIC OUT 12V DC 20mA _ Neutral + 11 LOGIC OUT 12V DC 20mA ENDA 0 SN: XXXXXXXXX INDUSTRIAL ELECTRONICS EPA741-24VAC PROGRAMMABLE AC/DC AMMETER T/2 T 3T/2 2T A 1 3 0.000 A 1 3 -A EPA741-E-07-R RUNNING MODE EPA 741 2450 OUT AC DC LO.LI UP.LI. AC/DC In Running mode, you can enter Up.l1 or lo.l1 menus by using value you want by following the parameter adjustment method. SET Means, measured current value is higher than up scale. Means, measured current value is lower than down scale. ---- key.Then you can adjust the SET SET & ENDA ERROR MESSAGES ---- To skip the programme mode while in operation mode press and keys at the same time.For returning back to operation mode you should follow the same way while you are in upper menu. PROGRAMMABLE AC/DC AMMETER PROGRAMMING MODE A.S.E.T UP.LI. LO.LI Upper limit value can be adjusted between lower scale and upper scale that specified with c.t.r.r parameter.This parameter can’t be lower than (lo.l1 + HYS.l + HYS.U ) value. HYS.U. Lower limit value can be adjusted between lower scale and upper scale that specified with c.t.r.r parameter.This parameter can’t be upper than (UP.l1 - HYS.U - HYS.L ) value. HYS.L. Hysteresis value for upper limit can be adjusted between 0 and c.tr.r/20. This parameter can’t be higher than (Up.l1 - Lo.l1 - Hys.l) value. Hysteresis value for lower limit can be adjusted between 0 and c.tr.r/20. This parameter can’t be higher than (Up.l1 - Lo.l1- Hys.U ) value. * Out.t A.dLY A.HYS dLY.U. Delay time for upper limit alarm can be adjusted between 0 and 900 seconds. dLY.L. Delay time for lower limit alarm can be adjusted between 0 and 900 seconds. A.out. Alarm output position can be adjusted n.o. or N.c. If n.o. is adjusted , output relay is powered at alarm condition. InPt tYPE c.tr.r Measuring type can be adjusted ac ,dc or acdc.Three leds shows measuring type at the top of the display. Current transforming rate can be adjusted between 5.00(/5) and 9999(/5).If this parameter changes upper limit value sets to upper scale ,lower limit value sets to lower scale and hysteresis values set to 0. Adjusting Decimal Number (*) There is only 1nPt menu at the models(EPA741 , EPA741-24 , EPA741S , EPA741S-24) that has no relay. c.tr.r Parameter Adjustment Method SET & 5.00 5.0 SET To adjust the selected parameter hold down key then you can adjust by using and keys. If you hold down the keys for 0.6 seconds while changing the parameters you skip to fast change mode. If you hold down the keys more than 5 seconds the active parameter would change faster. If you wait 25 seconds before holding down the keys or power off and power up again, you skip to operation mode. If current transforming rate is lower than 10, measuring value can be displayed like (0.00) or (0.0). If current transforming rate is between 10 and 100 ,measuring value can be displayed like (0.0) or (0). If current transforming rate is higher than 100, measuring value can be displayed like only (0). To change the designation of decimal number press you want by using key again. 3/3 SET key while in c.tr.r menu then select the one EPA741-E-07-R