Backup States B-9 You can selectively enable equivalence checking for none, some, or all of the 6 of the equivalence check areas, with one exception: the Program File Structure and Program File checksum is dependent on the Data Table Structure. Thus, if you select the Program File Structure and Program File equivalence check, you should also select the Data Table Structure equivalence check. Equivalence checking is only performed during qualification. Once a PLC-5 system passes qualification, it does not become disqualified even if the checksums for an area are different and the equivalence checking for that area is enabled. For example, if the Program File Structure and Program File equivalence check is enabled and there is a qualified secondary, you can edit the program files on either system without causing the secondary system to disqualify. However, if one of the PLC-5 systems goes out of Run mode and back into Run mode and a qualification occurs, an equivalence check failure during qualification causes a major fault to be declared for the qualifying system. Therefore, when performing edits on either PLC, we recommend that you disable equivalence checking first to avoid the condition where a PLC-5 processor cannot become qualified due to failing an equivalence check. Once all the edits are tested and placed into both PLC-5 systems, you can reenable the equivalence check. Word 49 in the ControlNet Backup Configuration and Status file gives you equivalence check status for a qualified backup system. A bit is set for each equivalence check area if the equivalence areas checksum differs between the two processors. This word is updated every few seconds so that you can know, if secondary qualification were to happen, which equivalence checks would pass, and which equivalence checks would fail. • Complete data table crossload If all the equivalence checks pass, a Qualification Data Table crossload is performed. This crossload reads the data table file values from the primary system and writes those values into the corresponding data table files in the secondary system. This data table crossload is performed while the qualifying PLC-5 system is still in Program mode. It is necessary to remain in Program mode until the data table crossload is finished in order to prevent the qualifying system from major faulting or going into an odd state due to uninitialized data table values. It is safer for the qualifying PLC-5 system to first do the Data Table crossload and then to go into Run mode. In that case, the data table values are close to the values on the currently executing primary system. Note: The time it takes to do the Qualification Data Table crossload primarily depends on the amount of data table data to be crossloaded. 3XEOLFDWLRQ)HEUXDU\