TROUBLESHOOTING
12
All NVS9000 slaves (cameras) should have contiguous addresses (Id) and be positioned
before the scanner slaves.
The scanner slaves should have contiguous addresses. The assigned scanner address
(Scanner Cluster>Scanner # Address parameter), seen by the decoder starts from the last
used decoder/camera address and therefore must follow this rule in the WebSentinel
configuration. The individual scanner slave nodes are labelled as hybrid in order to identify
their special operating mode.
When the SC6000 Controller is the dedicated scanner cluster master, it is not explicitly
visible on the WebSentinel interface. If instead, one of the hybrid scanners is the scanner
cluster master it does not appear differently from the other hybrid slave scanners. In any
case, it is the scanner cluster master which allows hybrid slave scanner configuration
through Genius. See details in the examples given in the next paragraph.
HOW TO CONFIGURE AN NVS9000 HYBRID ARRAY MASTER
The following steps are extracted from the general complete procedure shown in chapter 3.
Here particular details for this type of array configuration are shown, however the complete
procedure should in any case be followed for correct configuration.
1. Open the Settings window by clicking the
icon to add and configure the array(s).
2. Add an Array and complete the following fields then save:
a.
Array Type - select the Hybrid NVS item
b.
Array Name - this is the user-defined Array Label which appears in the Navigation Tree Area
c.
IP Address of the Array Device, in this case the NVS9000 Hybrid Master (i.e. 172.16.11.110)
d.
Port of the Array Device on which the WebSentinel agent is waiting for connection requests
e.
Configuration Tool's Port Number - default for Master Decoder 51235
Add Array link.
Specific Array
page for
Array Type
Hybrid NVS
Master.
Save button.