"Smarter Timing Solutions" ChapterThree Control and Status Commands This chapter will describes the ASCII protocol supported by the Praecis II. For the RS-232 serial I/O port physical and electrical characteristics see Appendix D - Specifications. General Serial I/O Operation The Praecis II commands are NOT case sensitive. It accepts input commands that are terminated with either an ASCII Carriage Return (CTRL-M, 0x0A) control character (denoted by <CR>) or an ASCII Carriage Return (CTRL-M, 0x0A) - Line Feed (CTRL-J, 0x0D) pair of control characters (denoted by <CR><LF>). The Praecis II terminates all status messages that it sends in response to commands with a <CR><LF> pair. The Praecis II does not ‘echo’ any user input. The Praecis II responds to invalid commands with: ERROR<CR><LF> or INVALID OPERATION<CR><LF> At power-up with factory default settings, the Praecis II outputs a time-of-day message once-per-second. The factory default emulation mode is NONE, and the Praecis II sends the time-of-day message in its native EndRun format. See Chapter 4 - Time-Of-Day Messages for details on the various clock emulation message formats. RECOMMENDED TERMINAL SETUP Use ANSI terminal emulation mode and turn OFF handshaking. 11 Praecis II User Manual