• Pressure regulators must have a fixed output
pressure of 30 mbar. The requirements of EN
12864, Appendix D, apply accordingly. The
regulator must have a rate of flow of 1.2 kg/h.
• Connect the regulator knobs very carefully by
hand. do not use keys, pliers or similar tools.
• Use the de-icing system (Eis-Ex) for the
regulator knobs when the temperature drops
below 5° C.
Before first use
• Ventilation openings should remain unob•
•
•
•
structed.
If necessary, remove snow from the flue.
Remove any dirt and snow/debris mixture
from the suction openings under the vehicle
floor; otherwise, the levels of carbon monoxide could increase to dangerous levels.
The safety ventilation openings may not be
closed.
We recommend that you keep a fire extinguisher that uses drying powder, with a capacity of at least 1 kg, by the entry door, as well
as a fire blanket by the cooker. Ensure that
everyone is familiar with the fire prevention
measures on site (see also 2.1 General information).
Read the operating instructions from
the manufacturer carefully.
Never use portable cooking or heating equipment, except for electrical
heating equipment (note the power
consumption), but not radiant heaters, because these may cause a fire
or risk of suffocation.