Download USER`S MANUAL - Graftek Imaging Inc
Transcript
DRAFT Configuring the Camera 4.2.2.2 Feature Control and Status Register Details Video Data Output Mode CSR Register Base Address: 0x1700 Field Name: Register Status Offset: 0x0000 Size: 1 Byte Type: Read only Description: The integer value in this field indicates the status of this control register: 0x00 = The register is not available 0x01 = The register is available. All related settings are OK 0x80 = A value in this register is set out of range Field Name: Mode Offset: 0x0001 Size: 1 Byte Type: Read / Write Description: Writing an integer value to this field sets the video data output mode: 0x01 = 2 tap 8 bit output (A402k) 0x03 = 2 tap 10 bit output (A402k) 0x10 = 4 tap 8 bit output (A403k and A404k) 0x12 = 4 tap 10 bit output (A403k and A404k) 0x11 = 8 tap 8 bit output (A404k) See Sections 2.5.5 (A402k), 2.5.6 (A403k) and 2.5.7 (A404k) for descriptions of the video data output modes. Exposure Time Control Mode CSR Register Base Address: 0x1400 Field Name: Status Offset: 0x0000 Size: 1 Byte Type: Read only Description: The integer value in this field indicates the status of this control register: 0x00 = The register is not available 0x01 = The register is available. All related settings are OK 0x80 = A value in this register is set out of range Field Name: Mode Offset: 0x0001 Size: 1 Byte Type: Read / Write Description: Writing an integer value to this field sets the exposure time control mode: 0x00 = Free-run programmable 0x02 = Free-run edge-controlled 0x04 = ExSync level-controlled 0x05 = ExSync programmable 0x06 = ExSync edge-controlled See Section 3.3 for descriptions of the exposure time control modes. BASLER A400k 4-15