2. Select the COM port where the MC9S08JMxx CDC driver is connected (see System
Properties/Device Manager/Ports). The communication speed is 9600 Bd.
3. The next step is to toggle the communication button. After that in bottom right corner should be
RS232;COMxx;9600, which means the communication is established.
4. If not, toggle (STOP) the communication and unplug/plug the FreeMASTER USB cable. Then
toggle (START) the communication button.
Figure 6-2. FreeMASTER Communication Settings
The FreeMASTER’s control page offers a similar interface as the manual controls, although it offers some
other features such as the change of operational mode settings, and displays some additional status
information.
To start a remote operation, run FreeMASTER and open the project file located at
...\Freemaster\AG128_BLDC_Sensorless.pmp.
The remote operation is active when the START/STOP switch is in the START position. The motor speed
can be set to any value within the range of 400 to 4000 rpm. The DC bus current (torque) can be set to any