Download User Manual - IRT Communications
Transcript
I R T Electronics Pty Ltd A.B.N. 35 000 832 575 26 Hotham Parade, ARTARMON N.S.W. 2064 AUSTRALIA National: Phone: (02) 9439 3744 Fax: (02) 9439 7439 International: +61 2 9439 3744 +61 2 9439 7439 Email: [email protected] Web: www.irtelectronics.com IRT Eurocard Type DVA-3007 270 Mb/s ASI/SDI 8 O/P Reclocking Distribution Amplifier Designed and manufactured in Australia IRT can be found on the Internet at: http://www.irtelectronics.com 3007-dva.ib.doc Page 1 of 9 26/02/2003 DVA-3007 270 Mb/s ASI/SDI 8 O/P Reclocking Distribution Amplifier Instruction Manual Table of Contents Section Page Operational safety Description Specifications Technical Description Installation Front & rear panel connector diagrams Maintenance & storage Warranty and service Equipment return Drawing index 2 3 4 5 5 7 8 8 8 9 This instruction manual applies to DVA-3007 later than S/N 0304001 Operational Safety: WARNING Operation of electronic equipment involves the use of voltages and currents that may be dangerous to human life. Note that under certain conditions dangerous potentials may exist in some circuits when power controls are in the OFF position. Maintenance personnel should observe all safety regulations. Do not make any adjustments inside equipment with power ON unless proper precautions are observed. All internal adjustments should only be made by suitably qualified personnel. All operational adjustments are available externally without the need for removing covers or use of extender cards. 3007-dva.ib.doc Page 2 of 9 26/02/2003 Description BLOCK DIAGRAM DVA-3007 SIGNAL PATH OUTPUTS (Optional ZDA-3006RL Bypass Rear Assembly) (Number of outputs reduced to 6) O/P 1 O/P 2 O/P 3 O/P 4 RECLOCKING INPUT EQUALISER O/P 5 SIGNAL FAIL DETECTION O/P 6 O/P 7 O/P 8 MON O/P LINK RL 1 RL1 ALARM O/P Relay RL 1 = Output Alarm The DVA-3007 270 Mb/s serial digital video distribution amplifier provides the user with a single standard module to cover a wide range of distribution and monitoring functions for SDI or ASI signals. Due to the fact that standard loop through techniques used in the analogue domain are unsuitable to the digital domain most digital equipment comes with no facility to route the input signal to other locations. As a result a VDA is required at almost every point in the digital chain. Serial digital signals also suffer severe deterioration over relatively short cable distances. The DVA-3007 provides a means of extending the working distances that can be achieved by equalising, reclocking and re-transmitting the data mid route. Where a large number of reclocked outputs are required the DVA-3007 may be used to provide reclocking and its outputs fed to one or more DVA-3006 non reclocking DA’s to provide the number of outputs required. This provides a more economic solution than using multiple reclocking DA’s and minimises jitter increase due to unnecessary re-clocking. An optional rear assembly, ZVA-3006RL (sold separately), provides a bypass relay to switch the Input (SK1) to Output 1 (SK2) in the event of a power failure. When this bypass rear assembly is used, the number of outputs is reduced to 6. The DVA-3007 may be mounted in IRT’s 1 RU or 3 RU frames with other analogue or digital modules. Features: • • • • • • For use as buffer or distribution amplifier. 8 x in-phase 270 Mb/s ASI or SDI reclocked outputs. Automatic input equalisation to 250 metres. Automatic output muting on no input. May be used in conjunction with non-reclocking DA’s to provide multiple reclocked outputs. Front panel indicators provide monitoring of presence of input signal at 270 Mb/s. 3007-dva.ib.doc Page 3 of 9 26/02/2003 Technical Specifications DVA-3007 Video input: Number Impedance Return loss 1. 75 Ω. >20 dB 5 MHz to 270 MHz. (>15 dB with optional ZVA-3006RL bypass rear assembly) Equalisation Automatic, better than 250 metres at 270 Mb/s for Belden 8281 or equivalent cable. (reduces to 200m when LK2 is closed). Video outputs: Number Type Level Impedance Return loss 8 ASI or SDI plus one front panel monitoring output. Reclocked. 800 mV ±10% into 75 Ω. 75 Ω. >20 dB 5 MHz to 270 MHz. DC offset Nil. (>15 dB with optional ZVA-3006RL bypass rear assembly) Performance: Reclocking Factory set for 270 Mb/s operation. Rise time Residual jitter <1.0 ns, (700 ps typically). <0.1 UI (measured with up to 300m of Belden 8281 or equivalent cable). Connectors: BNC 75 Ohms. Indicators: Power Signal present LED (green) for +5 V. LED (green) when valid ASI/SDI signal present. Alarm: Signal loss Power requirement: Voltage Consumption Contact closure. Link selectable NO/NC. 28 Vac CT (14-0-14) or ±16 Vdc 2.5 VA (including ZVA-3006RL optional rear assembly). Other: Temperature range Mechanical Finish: Front panel Rear assembly Dimensions Standard accessories Optional accessories 0 - 50° C ambient. Suitable for mounting in IRT 19" rack chassis with input, output and power connections on the rear panel. Grey background, black lettering & red IRT logo. Detachable silk-screened PCB with direct mount connectors to Eurocard and external signals. 6 HP x 3 U x 220 mm IRT Eurocard. Rear connector assembly with matching connector for alarm output. ZVA-3006RL relay bypass rear assembly (6 O/P). Due to our policy of continuing development, these specifications are subject to change without notice. 3007-dva.ib.doc Page 4 of 9 26/02/2003 Technical Description The input circuit of the DVA-3007 consists of an adaptive cable equaliser IC, which automatically adapts to equalise any cable length from zero metres to lengths that attenuate the signal by 40 dB at 200 MHz. This corresponds to 300 metres of Belden 8281 cable. When link LK2 is closed equalisation is reduced to 200m for use in noisy environments or when a short cable is used. A carrier detect and output mute circuit is used to mute the output when no signal is present. The DVA-3007 is insensitive to the pathological patterns that can be present in the serial digital video signal. The DVA-3007 also features an OUTPUT MONITOR point on the front panel. The output monitor is an isolated copy of the signal present at the rear panel outputs. The output of the input stage is coupled to reclocking circuit, which then feeds cable driver circuits to provide the eight isolated in phase outputs from the DVA-3007. The input cable equaliser circuit U1 and reclocking circuit U2 incorporate carrier detection circuits to mute the output when no signal is applied to the unit. The carrier detect signal and lock signal of U2 are used to energise relay, RL1 via a transistor, Q1, when locked carrier is present. The relay contacts are connected to SK10 on the rear panel to give a failure alarm in the form of a make (or break) to ground on failure as set by a link LK1, on the circuit board. The dual AC inputs are rectified and then regulated by a switch mode regulator circuit to provide the +5V operating voltage for the unit. +5Vdc is fed to pin 32a of the rear Euro-connector via a polyfuse, JP2. The +5V is to provide power for a signal bypass relay on the optional ZVA-3006RL bypass rear assembly, should one be used. The polyfuse protects the +5V power rail by going high impedance should pin 32a be shorted to ground. This protects against the accidental insertion of the DVA-3007 in anything other than its standard rear assembly or the optional ZVA-3006RL rear assembly. Installation Handling: The DVA-3007 contains static sensitive devices and proper static free handling precautions should be observed. When individual modules are stored, they should be placed in antistatic bags and proper antistatic procedures should be followed when inserting and removing cards from these bags. Power: Ensure that the voltage selection of the IRT mounting frame used to house the DVA-3007 and the local AC mains supply voltage match and that the correct rating fuse is installed in the mounting frame power supply. Earthing: Chassis earth connection of the equipment mounting frame is via the earth connection on the three pin (IEC) AC mains supply inlet. This is a safety earth and must be connected. Installation in frame or chassis: See details in separate manual for selected frame type. LK1 is factory set for a contact make to ground on signal failure at SK10 pin 2 on the rear panel, move LK1 from the normally closed (N/C) to the normally open (N/O) position for a break to ground on signal or power loss. Link LK2 closed reduces the input equalisation to 200m for use in noisy environments or when a short input cable is used. The presence of 270 Mb/s locked signal is indicated by the ‘SIGNAL PRESENT’ front panel LED (green). The presence of the internal +5 Vdc supply is indicated by the front panel LED (green). 3007-dva.ib.doc Page 5 of 9 26/02/2003 It is recommended that unused outputs on the rear panel be terminated with 75-ohm termination plugs. 3007-dva.ib.doc Page 6 of 9 26/02/2003 Front & rear panel connector diagrams The following front panel and rear assembly drawings are not to scale and are intended to show relative positions of connectors, indicators and controls only. Optional bypass relay rear assembly ZVA-3006RL DV A-3 0 0 7 8 O/P ASI/SDI D.A. 6 O/P ASI/SDI D.A OUTPUTS POWER OFF BYPASS SK1-SK2. OUTPUTS SK9 OUTPUTS SK7 SK8 SIGNAL PRESENT SK7 SK6 SK5 SK6 SK5 OUTPUT MON DC SK4 SK2 SK4 SK3 SK2 SK1 INPUT SK3 SK1 2 INPUT 1 SK10 SK10 2 = Alarm SK10 1 = Gnd 2 RL1R 1 SK10 SK10 2 = Alarm SK10 1 = Gnd N140 Note that the ZVA-3006RL is an optional relay bypass rear assembly (sold separately), which bypasses the input direct to output 1 in the event of a power failure. This optional rear assembly is only compatible with both the DVA-3006 and DVA-3007 ASI distribution amplifiers and not the previous ASI/SDI distribution amplifiers, DVA-3001 to DVA-3005. 3007-dva.ib.doc Page 7 of 9 26/02/2003 Maintenance & storage Maintenance: No regular maintenance is required. Care however should be taken to ensure that all connectors are kept clean and free from contamination of any kind. This is especially important in fibre optic equipment where cleanliness of optical connections is critical to performance. Storage: If the equipment is not to be used for an extended period, it is recommended the whole unit be placed in a sealed plastic bag to prevent dust contamination. In areas of high humidity a suitably sized bag of silica gel should be included to deter corrosion. Where individual circuit cards are stored, they should be placed in antistatic bags. Proper antistatic procedures should be followed when inserting or removing cards from these bags. Warranty & service Equipment is covered by a limited warranty period of three years from date of first delivery unless contrary conditions apply under a particular contract of supply. For situations when “No Fault Found” for repairs, a minimum charge of $A100.00 will apply, whether the equipment is within the warranty period or not. Equipment warranty is limited to faults attributable to defects in original design or manufacture. Warranty on components shall be extended by IRT only to the extent obtainable from the component supplier. Equipment return: Before arranging service ensure that the fault is in the unit to be serviced and not in associated equipment. If possible, confirm this by substitution. Before returning equipment contact should be made with IRT or your local agent to determine whether the equipment can be serviced in the field or should be returned for repair. The equipment should be properly packed for return observing antistatic procedures. The following information should accompany the unit to be returned: 1. 2. 3. 4. 5. 6. 7. A fault report should be included indicating the nature of the fault The operating conditions under which the fault initially occurred. Any additional information which may be of assistance in fault location and remedy. A contact name and telephone and fax numbers. Details of payment method for items not covered by warranty. Full return address. For situations when “No Fault Found” for repairs, a minimum charge of $A100.00 will apply, whether the equipment is within the warranty period or not. Please note that all freight charges are the responsibility of the customer. The equipment should be returned to the agent who originally supplied the equipment or, where this is not possible, to IRT direct as follows. Equipment Service IRT Electronics Pty Ltd 26 Hotham Parade ARTARMON N.S.W. 2064 AUSTRALIA Phone: Email: 3007-dva.ib.doc 61 2 9439 3744 [email protected] Page 8 of 9 Fax: 61 2 9439 7439 26/02/2003 Drawing Index Note: Components marked n/c on the diagrams are optional and are not included on standard production units. They are shown to assist with interpretation of additional or optional functions, which may be included or are necessary for factory set-up procedures. Drawing # Sheet # Description 804516 804673 1 DVA-3007 Circuit Schematic ZVA-3006RL Bypass Relay Rear Assembly (optional). 3007-dva.ib.doc Page 9 of 9 26/02/2003 PCB 804517 'SIGNAL' 'DC' MON. O/P LD2 HLMP-1503 'grn' R39 680R +5V LD1 HLMP-1503 'grn' R40 680R +5V 2 21 1 10K R38 2 C36 100nF 1 Input Signal Detect Monitor O/P Output 7 GND 1 +5V 4u7 RL1A V23026 C37 804516s3.sch GND +5V 10 1 ALARM CIRCUIT RL1B 2 n.o. n.c. CONTACT CLOSURE (OR BREAK) 5 LK1 C46 10nF TO GROUND ON ALARM, AS SET BY LK1 2 AC 4 AC 3 AC CT AC 2 AC 1 Power Supply Circuit Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 Output 8 +5V 804516s2.sch Q1 BSS123 D3 BAS16 +5V +5V 3 1 1 2 21 1 1 3 SK11 2 1 3 8 3 2 2 1 Input, Reclocking and Output Circuit 2 2 +5V 1 1 JP2 RXE020 POLYFUSE 10nF C45 1A 1B 2A 2B 3A 3B 4A 4B 5A 5B 6A 6B 7A 7B 8A 8B 9A 9B 10A 10B 11A 11B 12A 12B 13A 13B 14A 14B 15A 15B 16A 16B 17A 17B 18A 18B 19A 19B 20A 20B 21A 21B 22A 22B 23A 23B 24A 24B 25A 25B 26A 26B 27A 27B 28A 28B 29A 29B 30A 30B 31A 31B 32A 32B DIN64RA P1 DIN64 J1 1A 1B 2A 2B 3A 3B 4A 4B 5A 5B 6A 6B 7A 7B 8A 8B 9A 9B 10A 10B 11A 11B 12A 12B 13A 13B 14A 14B 15A 15B 16A 16B 17A 17B 18A 18B 19A 19B 20A 20B 21A 21B 22A 22B 23A 23B 24A 24B 25A 25B 26A 26B 27A 27B 28A 28B 29A 29B 30A 30B 31A 31B 32A 32B 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 R1R L1R R2R L2R R3R L3R R4R L4R R5R L5R R6R L6R R7R L7R R8R L8R R9R L9R 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 5 3 1 1 1 1 1 J2 P2 J2 optional power in 1 2 3 9 7 5 3 1 COPYRIGHT 2 01-08-02 ECR1368 3 14-11-02 ECR1412 4 20-02-03 ECR1441 K.N. Date: 26-Feb-2003 Revision: 1 ENG. APP. CHECKED DRAWN DO NOT COPY NOR DISCLOSE TO ANY THIRD PARTY WITHOUT WRITTEN CONSENT DVA-3007 SDI/ASI Reclocking Distribution Amplifier Drawing No. 804516 Title Sheet 1 of 3 IRT Electronics Pty. Ltd. ARTARMON NSW AUSTRALIA 2064 SCALE N.T.S. A3 SIZE (used when fitted to FRU-1030 frame) SK1 INPUT JP6 0R0 JP5 0R0 JP4 0R0 JP3 0R0 6 4 2 L1R-L9R = 15nH R1R-R9R = 68R SK10 2 2 2 2 SK2 SK3 SK4 SK5 SK6 SK7 SK8 OUTPUTS SK9 P3 1 02-04-02 PCB 804674 DIN64 J1 1A 1B 2A 2B 3A 3B 4A 4B 5A 5B 6A 6B 7A 7B 8A 8B 9A 9B 10A 10B 11A 11B 12A 12B 13A 13B 14A 14B 15A 15B 16A 16B 17A 17B 18A 18B 19A 19B 20A 20B 21A 21B 22A 22B 23A 23B 24A 24B 25A 25B 26A 26B 27A 27B 28A 28B 29A 29B 30A 30B 31A 31B 32A 32B 1 1 1 1 2 1 1 2 1 1 1 1 1 1 R2R L2R R3R 75R L3R R9R R4R 75R L4R R8R R5R L5R R6R L6R R7R L7R 2 1 2 2 2 2 2 2 2 2 1 2 2 1 2 2 2 2 2 2 SK10 JP5 0R0 JP4 0R0 JP3 0R0 JP2 0R0 SK3 SK4 SK5 SK6 OUTPUTS SK7 MTMM-103 1 1 1 1 6 4 5 2 P3 3 J2 optional power in J2 MTMM-105 P2 13 14 15 16 17 18 19 20 21 22 (used when fitted to FRU-1030 frame) 1 2 3 9 7 5 3 1 D1R 3 1 BAS16 G5Y-254P RL1R 2 1 10 9 8 7 6 5 4 3 2 1 R1R 56R 2 2 1 L1R 18nH 1 SK2 SK1 INPUT 1 11-07-02 2 11-11-02 ECR1415 Date: K.N. 14-Nov-2002 Revision: 1 ENG. APP. CHECKED DRAWN DO NOT COPY NOR DISCLOSE TO ANY THIRD PARTY WITHOUT WRITTEN CONSENT COPYRIGHT R2R-R7R = 220R L2R-L7R = 18nH Sheet 1 of 1 ZVA-3006RL SDI/ASI D.A. Rear Panel Drawing No. 804673 Title IRT Electronics Pty. Ltd. ARTARMON NSW AUSTRALIA 2064 SCALE N.T.S. A3 SIZE