Download WEBster - Alcorn McBride
Transcript
Table of Events: Here you will find the events in the WEBster you can schedule. For a detailed discussion see the previous Events in Detail section. Delimiter Field 1 Field 2 Field 3 Field 4 SendString String Acknowledgment string to look for* Timeout in seconds before retry or failure* Number of retries* StartSequence <sequence index> N/A N/A N/A SetVarEQ <variable index> <value> N/A N/A On <output or flag index> N/A N/A N/A Off <output or flag index> N/A N/A N/A DefaultWebPage <pagename> N/A N/A N/A * optional parameter Indices for sequences, variables, flags, and outputs: WinScript refers to resource as resource+1 , like variable0 as variable1, variable12 as variable13,etc…, so don’t let this confuse you. Resource Field 1 Sequence 0x00 – 0xFF State Variable 0x00 – 0x1F Output 0x00 – 0x3F Flag 0x40 – 0x7F Fields in Detail There is a summarized table in the File Format/Tutorial section that lists all the fields for your reference. Since the Event, and event Parameter fields (E:, 1:, 2:, 3:, and 4: ) have been been discussed in detail in the Events in Detail section, we’ll discuss the rest of the fields here. T: Start Time The Start Time is the hour and minute your event becomes active. For most cases being active simple means gets executed. You specify it in military time 00:00 is midnight, 23:59, 11:59pm, is last minute of the day something can be scheduled. You can specify the word BOOT as the field’s value. This used to make an event get executed upon every reboot after the start time and start day have been reached. Example: T:13:30 T:Boot November 2, 2005 • Alcorn McBride WEBster User’s Manual • Rev 1.9 • Page 61