IDEA 6.2.10 Operating Manual - English Machine Messages 6.2.10.1 ALARM MESSAGES Nº 1 This message indicates that during advancement the cutter or tracer point has encountered an unexpected obstacle. For example: • a foreign body has been left on the clamp. • the key has not been positioned properly (vertical instead of horizontal) or does not correspond to the one required by the selected SSN. • a clamp has been installed different from the one required for the job/decoding in progress. • the wrong adapter has been fitted or is not required for the job/decoding in progress. Nº 2 The message indicates that the clamp required by the program flow for cutting or decoding has not been gauged. Carry out the CLAMP GAUGING instructions given. Nº 3 The permitted temperature has been exceeded on the electronic control board. Check the cooling fan (see ch.7.1 "Trouble shooting"). Nº 4 Signals that the fuse has cut out due to a short circuit in one of the inputs or outputs (see ch.7.1 "Trouble shooting"). Nº 5 Signals a short circuit on port P (IN/OUT) (see ch.7.1 "Trouble shooting"). Nº 6 Signals that fuse F1 has probably cut out (see ch.7.1 "Trouble shooting"). Nº 7 Signals a fault on the electronic circuit board. 110 Copyright Silca 2004 ALARM 1 Faulty contact made! Press START to move axis at zero point. ALARM 2 Clamp not calibrated ! ALARM 3 HIGH TEMPERATURE Turn machine off! ALARM 4 I/O POWER Check fuse F4! ALARM 5 DIGITAL OUTLET Turn the machine off! ALARM 6 CUTTER MOTOR Check fuse F1! ALARM 7 CUTTER MOTOR Motor circuit anomaly!