IDEA Operating Manual - English Reading KEY READING Original on right Clamp: S100 A - B Stop:0 Adapt. E16 [START] Is adaptor E16 installed ? Yes=START max 31 mm No=STOP max 7 mm max 15 mm 1) Press on the grip lever of the fixed clamp (A) and fit the centring device E16 so that it protrudes towards the mobile clamp (B) (fig. 82). Release the grip lever. 2) Press on the grip lever on the mobile clamp (B) and fit the key so that the hole in the stem is up against the centring device E16 (fig. 83). Release the grip lever. 3) Hold the key head with one hand and the end of the centring device with the other and push the key up against the stop 0 (A). 4) The ideal position for the mobile clamp (B) is when there is a distance of 3 mm min. and 15 mm max. between the bit and inner side of the mobile clamp (B). Clamp: S100 A-B = indicates the clamp (S100) into which the key must be fitted, and which jaw to use. Stop 0 = reference or point for positioning the key on the reading clamp. Adapt: E16 = adapter for positioning the key (female) from the tip (only for reading). ATTENTION: make sure that the bit is up against the Stop 0 (A). Fig. 82 Pressing Start shows: Left blank Brass Clamp: S1-K1 Stop:0 Cutt: 1.25 Adptt: E15 pcs. = 1/1 [START] Is adaptor E15 installed ? No=STOP Yes=START Fig. 83 58 Copyright Silca 2004 Note: Maximum dimensions of keys for Reading from the original: - Max. stem thickness = 7 mm - Max bit length = 31 mm - Max. bit height = 15 mm If these conditions are not observed, the machine will produce the error “Key cannot be decoded”.