Download V5-G/V6-G dedicated vector and torque control frequency inverter
Transcript
V6/V5-G special inverter for crane application http://www.ecodrivecn.com Set this function, and the operation panel will display the function code parameters according to the actual need of the user to improve the work efficiency. 0: Basic menu mode: The operation panel can display all the parameters. 1: Fast menu mode: The operation panel only displays the fast parameters defined by the manufacturer. When the basic functions of the inverter are used, this menu mode shall be set. 2: Menu mode of non-leave-factory value function code: The operation panel only displays the parameters different from the leave-factory values. When the technical personnel perform onsite maintenance, to quickly view the parameters set by the user and detect the failure, this mode can be used. After the inverter commissioning is completed, to conveniently record and inquire the modified parameters, this mode can be set. 3: Menu mode of last changed 10 function codes: When the inverter has abnormal operation or it is necessary to inquire the commissioning parameters, the last changed 10 parameters can be inquired by setting this menu mode. When the leave-factory parameters are recovered, the record of the last changed 10 function codes will also be cleared. Note: Both P0.00 and P0.02 are visible in all the menu display modes for the convenience of menu mode switching. Press ESC key and hold for over 5 seconds, it will restore to basic menu mode, and P0.02 is automatically restored to 0. In non-basic menu mode, the >> key cannot be used to switch the function zone code and group number. The current menu mode will be displayed after pressing the >> key for several time P0.03 encoder installation option 0~8(0) 0; Do not install the encoder, run by open-loop torque vector control, it is applied for application without encoder, V5-G&V6-G are valid 8; Install the encoder, run by closed-loop torque control, it needs to install pulse encoder . Compared with sensorless vector control, it has steady speed with a higher accuracy, faster torque response, more powerful low-frequency torque control performance, only valid V6-G. P0.04 Remote Control Speed reference mode 0~4(0) By Remote Control Speed reference mode(P0.06≠0) If reference frequency is lower that brake open frequency, then reference frequency is brake open frequency. 0; by d2.03 scalar to set frequency, d2.03 from 0~100.00 correspond to 0~P0.11 Max. Frequency. Notes; If multi-section digital voltage terminals 1 ~ 4 are valid the frequency is determined by the terminal combination. Refers to 0.00~H0.14. 1: Set frequency reference via AI1 port. 2: Set frequency reference via AI2 port. Input specification of AI1 and AI2 terminals: 0~10V or 0~20mA. The correspondence relation between the analog and the reference frequency is defined by group P6. Chapter 5 Parameter Description http://www.ecodrivecn.com 46