Download NEXO Nemo-User Guide
Transcript
NEXO NeMo User Guide v1.4 Power Amp DC Output Alert (per ch.) The output DC value of a given amplifier channel is greater than 10V. ü ü Power Amp Overtemperature (per ch.) Over-temperature value of the power amplifier (no over-temperature, >70°C and reducing output by 3dB, >80°C and reducing by 6dB), >90° and muting output). ü ü Peak Limiter (per ch.) The peak limiter is working to protect the amplifier for the channel. Orange LED (Network and Control tabs) ü ü Protection (per ch.) Speaker thermal) Orange LED (Network and Control tabs) ü ü Amp protect Protection status of the amplifier. If protecting, it is reducing or muting one or several outputs due to malfunctions as overheating, output DC, short circuitry… See the user manual for more details about the meaning of combinations of LEDs indicator and LCD display. Orange LEDs (Network and Control tabs) ü ü Sense (per ch.) A certain level of current is detected on the output (a cabinet is connected and some sufficient signal is flowing to it). Green LED (Network tab) protection (displacement or Please refer to the NXAMP’s user manual for more details about these parameters. Page 53 of 54