2.4.2.
Mechanical Rack Installation
The UE-9000 uses forced air ventilation, evacuating the air toward the left side
panel (left wall) of the 19” rack. To ensure smooth airflow, special “L” shape
slides are provided for rack mounting (see Figure 2-1). The brackets are
fastened with screws on the sides of the UE-9000 Chassis.
To prepare the UE-9000 for rack installation, fasten the brackets to the rack side
rails with four screws (not included in the kit), two in on each side.
Figure 2-1: Rack Mount Slides
CAUTION
ENSURE THAT A SUFFICIENT AMOUNT OF AIRFLOW ENTERS THE UE-9000 FROM THE LEFT END
(FROM THE FRONT PANEL POINT OF VIEW). CONSIDER IF OTHER DEVICES IN THE RACK USE
AIRFLOW IN THE OPPOSITE DIRECTION.