Download 82C900 User`s Manual
Transcript
82C900 Standalone TwinCAN Controller Communication via the SSC Table 2-3 Single Write Access Action Host action 1 Device action Activation of the SLS output signal to indicate the start of a new communication sequence. As soon as the falling edge of the SLS input signal has been detected, output RDY becomes active (1), indicating that the Standalone TwinCAN device is ready for data exchange. 2 The desired address (A) and the write- indication bit (1) have to be prepared and the transmission of the first byte is started as soon as RDY=1 has been detected. 3 - 4 Reception of a byte with an undefined After complete reception of the value. transferred byte, the write-indication and the seven address bits (A) are stored. Output RDY is set to indicate that the next byte can be transferred. 5 The transmission of the data byte to be written is started as soon as RDY=1 has been detected. User’s Manual The detection of the first clock edge for the current byte transfer resets output RDY. 2-14 V1.0D2, 2000-12