32
DWN. BY:
INSPECTED BY:
DATE:
1
CK
01-03-12 JM
SHEET NO.:
DWG. NO.:
SCALE:
1.0
REV.:
Figure 2
1.000:1.000
ASX-16B/C/D/P/E
Base and Step Levels
200 WOOD AVE. MIDDLESEX, NJ 08846
Base Level moves this
15dB "WINDOW" UP
or DOWN within the
limits of ABSOLUTE
Step 0 and ABSOLUTE
Step 1020.
ABSOLUTE step 1020. They output thier minimum power at
ABSOLUTE step 0. To insure that ALL MODULES can be adjustable
over the same range, some of the range of adjustability is sacrificed.
To prevent the strongest modules from producing too much power, their base levels
are lowered so that the strongest modules output the same range of output levels
as the weakest modules. (See Figures 3 and 4)
Level Step 0 (Lower Limit of Adjustement)
Level Step 480 (Level for FLAT output)
Level Step 720 (Upper Limit of Adjustment)
NOTE: Generator modules output their maximum available power at
Absolute Step 0 (Minimum Power Out)
Base Level
Absolute Step 1020 (Maximum Power Out)