Download section 1 - Apex Power Tools

Transcript
TMH SERVO MODULE
Connections
• All plug in connections are located on the front of the TMH.
• To adapt the TMH connections to the tool cable an extension cable is required
(Cooper Tools
No. 960948-XXX).
• All connections, except "XS1 Supply", can be secured from unintentional
unplugging with
screws or slide locks.
• The connections for motor, resolver and transducer are compatible with the mPro-400 fastening
system with measuring board S Torque and servo amplifier BLSH.
It is prohibited:
•
•
•
To operate the TMH and the handtool without PE (protected earth
ground) connections! Fatal electric shock may occur.
To use other connector types.
To use cables other than those approved by Cooper Tools.
Supply "Supply XS1"
• The connector coding ensures that the plug for XS1 cannot be plugged into
XS2.
Pin
1
2
3
4
5
6
Type: PHOENIX Power-Combicon PC4/6-7,62
Cooper Tools Id. No.: 960942 (incl. coding on pin 1)
Description
Supply of intermediate circuit of logic section (logic power supply) (230
VAC)
Supply of intermediate circuit of logic section (logic power supply) N
PE
Supply intermediate circuit 230 VAC
nc
Supply intermediate circuit N 230 VAC
USER MANUAL
Tork-Trak TM Fastening Controller
Automated Systems NA
Section 16 – 16
version: draft 0.5