Pre-Trigger
This option is available only for the Non-continuous operating mode.
For triggering via analog input or digital input, sets the amount of signal pre-history as
0..100% of recording depth (i.e. signal length).
Mode and polarity
Sets the type of triggering. Analog input: With over-run or under-run of the threshold/
limit value. Digital input: With logical 1 or logical 0.
Start-Stop trigger and number of trigger pulses
This option is available only for the Non-continuous operating mode.
This option dynamically controls the recording signal length for analog or digital input
triggering. Refer to triggering and recording.
Recording tab
Used analog inputs
Operation can reduce the number of analog inputs from 8 to 4 / 2 / 1. This reduces the
time for evaluation and for measurement data transmission, or increases the trigger ra­
te. Some functions are available only for settings of ≤4 channels. Refer also to project
planning.
This is setting takes priority over the analog inputs marked as Active.