11. OUTLINE MODEL AND SUFFIX CODE Ambient Temperature: -40 °C to 60 °C (-40 °F to +140 °F) Indicator’s operating range: -20 °C to 60 °C (-5 °F to +140 °F) Ambient Humidity: 0 to 100 % Lengthy continuous operation at 95 % humidity or more is not recommended. Power Supply: Power supply suffix code 1: • AC specifications Rated power supply: 100 to 240 V AC, 50/60 Hz (Operating voltage range: 80 to 264 V AC) • DC specifications Rated power supply: 100 to 120 V DC (Operating voltage range: 90 to 130 V DC) Power supply suffix code 2: • AC specifications Rated power supply: 24 V AC, 50/60 Hz (Operating voltage range: 20.4 to 28.8 V AC) • DC specifications Rated power supply: 24 V DC (Operating voltage range: 20.4 to 28.8 V DC) RXFA11 Magnetic Flowmeter Converter for Remote Flowtube: Allowable cable length m(ft) NORMAL OPERATING CONDITIONS Model Suffix Code Description Magnetic Flowmeter Converter RXFA11 General-Purpose Use G · · · · · · · · · · · · · For AXF Remote Flowtube of size 2.5 to 400 mm (0.1 to 16 in) Use Output Signal and Communication Power Supply Electrical Connections Indicator -D · · · · · · · · · · 4 to 20 mA DC, BRAIN Communication -E · · · · · · · · · · 4 to 20 mA DC, HART Communication 100 V to 240 V AC or 1········ 100 V to 120 V DC 2....... 24 V AC/DC *1) ANSI 1/2 NPT female -2 · · · · · · ISO M20 x 1.5 female -4 · · · · · · With Indicator 1···· Options / · Optional code (See the Table of Optional Specifications) T03.EPS *1) In case of power supply code 2 (24 V AC/DC), optional code /A (lightning protector) is mandatory. DEFAULT SETTINGS Size (mm) 420 (1380) Default span (m³/h) Default pulse weigth / total weight (unit / P) 15 2.5 0.1 280 ( 920) 25 5 0.1 200 ( 660) 32 10 0.1 40 15 0.1 50 20 0.1 65 50 0.1 100 ( 330) 0 20.4 22 24 26 28.8 Usable power supply range in Volt Cable cross section area: 1.25 mm2 Cable cross section area: 2 mm2 F00.EPS Vibration Conditions: Level of vibration in conformity with IEC 60068-2-6 (SAMA31. 1-1980) 0.5 G or less (frequency 500 Hz or less) Note:Avoid locations with much vibration (with a vibration frequency of 500 Hz or more), which may cause damage to the equipment. ACCESSORIES Fuse Time lag : 1 pc. - Power supply code 1: (T2.5A, 250 V) - Power supply code 2: (T3.15A, 250 V) Mounting bracket: 1 set 80 75 0.1 100 100 0.1 125 150 1 150 250 1 200 400 1 250 600 1 300 1000 1 350 1200 1 400 1500 1 450 2000 1 500 3000 1 600 4000 1 700 5000 1 800 7000 1 900 9000 1 1000 10000 1 T07.EPS Display: Line 1 : Flow rate Line 2 : Flow rate Bargraph Line 3 : Tag # if specified, else off IM 01R21C01-01E-E 1st edition, Oct. 2006 11-4