Transcript
To connect your regulator/hose assembly to the pressurized hydrogen cylinder, use the adjustable wrench to tighten the regulator inlet connector nut onto the compressed cylinder in a counter clockwise direction (figure 6&7). (3) Make sure the regulator inlet valve is closed. To close the regulator’s valve, turn the regulator’s adjusting knob in the counter clockwise direction. (4) Slowly open the compressed cylinder valve to observe the reading in the high pressure gauge (figure 8). This will indicate the internal pressure of the compressed cylinder, which should not be more than 200 Bar (2900PSI) (figure 10&11), but above 40 Bar (580 PSI). (5) Inspect the connections for leaks by applying some soap water on all connections (figures 12&13). If you notice bubbles