Download FA416 Installation Instructions

Transcript
Figure 2: FA416R / FA416DR receiver
Advance
Button
FA104 Programmer Port
Delete
Button
ADV
DEL
13.6V
GND
Output 1 LED
RESET
N/C
Output 2 LED
1 COM
Output 3 LED
N/O
Output 4 LED
N/C
Global Fault LED
2 COM
NC NO
N/C
3 COM
Tamper
Terminal
N/O
Transmitter
Programming Port
TMPR
COM
TX PRGM
N/C
N/O
RESET
4 COM
Output Select Jumper
FA116 Programmer Port
Reset Button
N/O
N/C
DECODE
VALID
DECODE
FA516 Display Module
Connector
N/O
Case Tamper
Switch
Fault Ouput Terminal
Note: References in this manual to features shown in Figure 2 will be printed in italics.
OUTPUT 1
OUTPUT 2
REVIEW
STATUS
ACTIVATED
TRANSMITTER
NUMBER
TAMPERED
OUTPUT 3
To open housing, insert small flat screwdriver at top or
bottom pry point indicator nubs (4 places). Gently twist or
pry housing cover away from base. Prying at any other
location will damage the housing.
OUTPUT 4
LOW BATTERY
FAULT
INACTIVE
FA416D
16 Channel Receiver
by Inovonics Corporation
Shown with access door removed.
To remove, insert small screwdriver
and gently pry door off.
Figure 3: FA416D / FA416DR receiver housing
OUTPUT 1
OUTPUT 2
OUTPUT 3
OUTPUT 4
FAULT
FA416
16 Channel Receiver
by Inovonics Corporation
Shown with access door removed.
To remove, insert small screwdriver
and gently pry door off.
Figure 4: FA416 / FA416R receiver housing
© 1997 Inovonics Wireless Corporation LIT-FA416-INSTALL
3
02304e 23-Oct-02