Download Manual - Korenix

Transcript
request time out duration to 200ms.
Set modbus TCP master
Switch(config)# modbus master
communicate session.
<1-20>
Max Modbus TCP Master
Switch(config)# modbus master 2  set maximum modbus
master up to 2; maximum support up to 20 modbus
communicate sessions.
Set modbus TCP listening port
Switch(config)# modbus port
port
Listening Port
Switch(config)# modbus port 502 ; default modbus TCP
service port is 502.
5.5
Revision History
Edition
Date
Modifications
V2.13
Nov,2014
V2.12
OCT-2014
Firmware v2.8a new features:
ITU-T G.8032 ERPS /Web UI change
Super Chain/Web UI change
Extend RDH ID: 256 RDH Rings /Web UI change
Multiple Realy Alarm /WebUI change
Etherent /IP /CLI Command change
Rate Control counting with Inter Frame gap, w/o
interface change
V2.11
20-Apr-2013
Firmware version v2.6a, v2.7 with following new
features.
V2.6a:
Add new features to Modbus TCP protocol
V2.7:
IPv6 features
Port-Based DHCP Server with fixed IP
addressfeatures
SSH, SSL certification key allows user change.
Support local console, SSH and SSL with Radius
authentication.
Telnet, HTTP service enable/ disable function
Restrict maximum 20 command entry records to be
storage in system.
Integrated JetNet 5010G and JetNet 4510 in one user
manual.
V2.10
18-Jun, 2012
Add CLI command:
Super Chain
RDH Ext. ID
 Add New Features – Port Based Loop Protect
function in network redundancy and waning
selection. ( firmware V2.6)
 Add new hardware version -2.3: power input range
10.5~60V dc, typical input DC24V.
137