Download SPM-8 Multi-Function Power Meter User guide
Transcript
SPM-8 Multi-Function Power Meter User guide 1 Content Chapter 1 Introduction 1.1 Product Introduction 1.2 Caution 1.2.1 Danger 1.2.2 PRODUCT WARRANTY & CUSTOMER SUPPORT 1.2.3 LIMITATION OF WARRANTY Chapter 2 Detail Specification 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 Power parameters measure Energy measure Demand measure Power Quality measure Report and event logging Display and input/output Communication Environmental & Physical Ordering Code Chapter 3 Installation 3.1 Safety 3.2 Mounting Chapter 4 Connection 4.1 Back view of connect port 4.1.1 Digital Output 4.1.2 Analog Output 4.1.3 Digital Input 4.1.4 Analog Input 4.1.5 Aux. Power Supply 4.1.6 Current Terminal 4.1.7 Voltage Terminal 4.2 Wiring diagram 4.2.1 1P2W/1CT 4.2.2 1P3W/2CT 4.2.3 3P3W/2CT 4.2.4 3P3W/3CT 4.2.5 3P4W/3CT Chapter 5 Function Tree Chapter 6 RunTime 6.1 Display 6.2 Runtime auto scroll Chapter 7 Set up mode operation 7.1 SPM-8 display and keyboard 7.2 Set up 7.2.1 Clear Function 7.2.2 Basic Setup 7.2.2.1 Communication 7.2.2.2 7.2.2.3 7.2.2.4 7.2.2.5 Measurement Security Alarm Set Point Clock Setup 2 7.2.2.6 Digital Output 7.2.2.7 Analog Output 7.2.2.8 Analog Input 7.2.2.9 Demand Setup 7.2.2.10 Period Reset 7.2.3 Display Setup 7.2.4 TOU Setup 7.3 Report 7.3.1 Daily Report 7.3.2 Diagnostic 7.3.3 Harmonics 7.3.4 Current on alarm 7.3.5 Event log 7.3.5.1 Sag Record 7.3.5.2 Swell record 7.3.5.3 Alarm Record 7.3.6 Analog input 7.3.7 Nameplate Info Chapter 8 Communication format 8.1 RS485 8.1.1 RS485 standard 8.1.2 Wiring for instruments communication 8.2 Modbus 8.2.1 Modbus Format8.3 Communication protocol 8.3 Communication protocol 8.4 IEEE 754 Format 8.5 Modbus RTU Mode 8.6 Modbus Function Code 8.7 Detail Parameter 3 Chapter 1 Introduction 1.1 Product Introduction SPM-8 series power meter is designed for continuous monitoring of 3 phase system. All essential power parameters measure including current, voltage, power, active and reactive energy are integrated in a single meter. Its bi-directional energy measurement and harmonic analysis function makes SPM-8 suitable for modern industrial power management. The built-in RS485 and rich communication abilities enable SPM-8 to be easily connected with most modern third-party SCADA systems. Features Standard Model Power parameters measure Current:3 phase, neutral, accuracy 0.1% Voltage:3 phase phase-phase, phase-neutral, accuracy 0.1% Frequency:47-63 Hz Total power:Active, reactive, apparent power, accuracy 0.5% Power per phase:Active, reactive, apparent power, accuracy 0.5% Power factor:Total, per phase Auto wiring detection Energy measure Energy:Active, reactive, apparent energy, accuracy 0.5% Bi-directional energy:Deliver and receive kWh, kVARh, kVAh Display and input/output Panel display:Mono 128 x 128 STN-LCD Digital input:12 channel dry contact inputs Digital output:2 channel relay for alarm and kWh pulse output Analog input:4 channel 4-20mA input(option) Analog output:4 channel 4~20 mA for V, I, kW, kVA, kVAR(option) Voltage connection:10- 600 V RMS(ph-ph) Current connection:5A RMS, minimum detetable current 2 mA Power supply:86~242 Vac or100~300 VDC Communication Primary port:RS485 Modbus Secondary port:Ethernet : 10/100 Mbps, Modbus over TCP/IP protocol(option) Demand measure Block/Rolling demand Power Quality measure Harmonic:V, I THD and individual harmonics Sag/Swell:Configurable setting points Report and event logging Report:Daily report : this day, yesterday;Regular report : this period, last reset Event logging:Sag, swell, alarm logging 4 Advance Model 1.2 Caution 1.2.1 Danger The meter contains hazardous voltages. The meter should never be disassembled. Failure to observe this practice can result in serious injury or death. Any work on or near energized meters, meter sockets, or other metering equipment can present a danger of electrical shock. It is strongly recommended that all work should be performed only by qualified industrial electricians and metering specialist. Shihlin assumes no responsibility if your electrical installer does not follow the appropriate national and local electrical codes. 1.2.2 PRODUCT WARRANTY & CUSTOMER SUPPORT Shihlin warrants all products free from defects in material and workmanship for a period of one year from the date of shipping. During the warranty period, we will, at our position, either repair any product that proves to be defective. To report any defect, please contact :+886-3-5981921 or [email protected] Please have the model, serial number and a detailed problem description available when you call. If the problem concerns a particular reading, please have all meter readings available. When returning any merchandise to Shihlin, a return materials calibration number is required. 1.2.3 LIMITATION OF WARRANTY This warranty does not apply to defects resulting from unauthorized modification, misuse, or use for reason other than electrical power monitoring. The supplied meter is not a user-serviceable product. 5 Chapter 2 General Features *:only in Advance model 2.1 Power parameters measure and accuracy Current:3 phase, neutral, accuracy < 0.1% Voltage:3 phase phase-phase, phase-neutral, accuracy < 0.1% Frequency:47-63 Hz Total power:Active, reactive, apparent power, accuracy < 0.5% Power per phase:Active, reactive, apparent power, accuracy < 0.5% Power factor:Total, per phase 2.2 Energy measure Energy:Active, reactive, apparent energy, accuracy < 0.5% Bi-directional energy:Deliver and receive kWh, kVARh, kVAh 2.3 Demand measure* Bi-directional Block/Rolling demand 2.4 Power Quality measure* Harmonic:V, I THD and individual harmonics, up to 31 orders Sag/Swell:Configurable setting points 2.5 Report and event logging* Report:Daily report : this day, yesterday Regular report : this period, last reset Event logging:Sag, swell, alarm logging 2.6 Display and input/output Panel display:Mono 128 x 128 STN-LCD Digital input:12 channel dry contact inputs Digital output:2 channel relay for alarm and kWh pulse output Analog input:4 channel 4-20mA input(option) Analog output:4 channel 4~20 mA for V, I, kW, kVA, kVAR(option) Voltage connection:10-600Vrms Current connection: 5Arms, minimun detetable current 2 mA Power supply:86~242 Vac or 100~300Vdc Power consumption:8W/15VA 2.7 Communication Primary port:RS485 Modbus or DNP 3.0 protocol * Secondary port :Ethernet : 10/100 Mbps, Modbus over TCP/IP protocol, 2.8 Environmental & Physical Operation temperature:-20℃to 60℃ Storage temperature:-25℃ to 80℃ Humidity:20-90%RH (non-condensing) Dimensions:144mm(L) x 144mm(W) x 94mm(H) 6 2.9 Ordering Code SPM-8 □ □ □ □ Model 0:Standard 1:Advanced Secondary Port 0:No secondary port 1:Ethernet AI function 0:Without AI function 1:With AI function AO function 0:Without AO function 1:With AO function Note:Standard Model offers no secondary port 7 Chapter 3 Installation 3.1 Safety On receipt of the instrument and prior to installation, makes sure it has not been damaged during shipment. The instrument is no longer safe when, a) shows clear signs of damage b) does not work c) long storage under extreme conditions d) damage during shipment 3.2 Mounting This instrument should install on vibration free switchboard and with environment temperature between -20℃~60℃, humility between 20-90%RH(no condensing) For the instrument is already equipped with an internal protection fuse, a 1AmAT HBC fuse is recommended during installation Prior to maintain/repair this instrument, always disconnect this instrument from all power sources Only have qualified and authorited personnel to carry out installation, maintainance and repair Water profe for front panel IP54, case IP20 After mounting the instrument, place all four support latch in position. Pannel cut-out area is 138x138mm(+or- 0.5mm) 8 Chapter 4 Connection 4.1 Back view of connect port 9. 8. 7. 4. 3. 2. 10. 1. 5. 6. 12. 11. 1. 2 3. 4. 5. 6. 7. 8. 9. 10. 11 12 AUX. power Digital output (Com2 DO2 Com1 DO1) Analog output (Com1 AO4 AO3 AO2 AO1) Digital input (Com1 DI4 DI3 DI2 DI1) Digital input (DI5 DI6 DI7 DI8 Com2) Digital input (DI9 DI10 DI11 DI12 Com3) RS485 port (D- D+) RS485 port (D- D+) Ethernet port Analog input (AI1+ AI1- AI2+ AI2- AI3+ AI3- AI4+ AI4-) Current terminal (3L 3S 2L 2S 1L 1S) Voltage terminal (C.B.A.N) 9 4.1.1 Digital Output 2 channel 4 pin digital output (Com2 DO2 Com1 DO1) 12-240VAC-DC/120mA max Com0 DO0 for digital output1, Com1 DO1 for digital output 2 Port 1 assign selection : V/I Unbal Alarm, THD Alarm, Over V/I Alarm, Under V Alarm, V/I Loss Alarm Port 2 assign selection : Energy pulse (pulse/kWh) 4.1.2 Analog Output 4 channel 5 pin current output (Com1 AO4 AO3 AO2 AO1) 4-20mA current output 4 analog output selection:phase, voltage, current, power… 4.1.3 Digital Input 3 groups of 12 channel, 15 pin digital input (Com1 DI4 DI3 DI2 DI1)、(DI5 DI6 DI7 DI8 Com2)、 (DI9 DI10 DI11 DI12 Com3) 5-24Vdc 4.1.4 Analog Input 4 channel 8 pin analog input(AI1+ AI1- AI2+ AI2- AI3+ AI3- AI4+ AI4-) 4-20mA input 10 4.1.5 Aux. Power Supply Before powering the instrument, verify the pin position at L and N, leave the middle pin blank. Power standard is 86-242Vac/100-300Vdc. An internal protection fuse 250V, 1A is equipped. The instrument power supply must not be earthed. 4.1.6 Current Terminal The current input are 3 channels/6 terminals(3L 3S 2L 2S 1L 1S) Input current range from 2mA to 5A (CT secondary) Warning ! The CT input current must not exceed 10A Warning ! Be sure to short secondaries of each current transformer, before removing the CT connection inputs. 4.1.7 Voltage Terminal There are 4 voltage terminals(C.B.A.N) 。 The instrument measure voltage from 10V-600V.(PT secondary) Voltage must not exceed 600V, in case of over 600V, voltage transformer need to be applied. Note ! 3P3W/2CT and 3P3W/3CT wiring, only connect “C A N”, and leave “B” blank OR 11 4.2 Wiring diagram 4.2.1 1P2W/1CT 3L 3S 2L 2S 1L 1S C B L N 4.2.2 1P3W/2CT 4.2.3 3P3W/2CT 12 A N 4.2.4 3P3W/3CT 4.2.5 3P4W/3CT 13 Chapter 5 Function Tree Select Manual Clear Function Basic Setup Setup Report Daily Reset Energy Reset Sag Reset Swell Reset Sag/ Swell Reset Alarm Rcd Rese Reset to Default Reset All Demand Reset Period Reset Communication Modbus Baud Rate CM1 Unit ID Stop Bit Parity Bit Ethernet IP Address Port No Subnet Mask Gateway Mac Address Measurement Volts Mode PT Primary PT Secondary CT Primary CT Secondary Frequency Security Alarm Set Point Modify PWord Enable/Disable Sag/Swell Limit Sag Limit Swell Limit Ref. Primary Voltage Alarm Set Point Alarm Clear Point Setup Display Setup Clock Setup Date Time Digital Output Digital Output 1 Digital Output 2 Analog Output Analog Output 1 Analog Output 2 Analog Output 3 Analog Output 4 Analog Input Analog Input 1 Analog Input 2 Analog Input 3 Analog Input 4 Demand Setup Mode No. of Subinterval Subinterval Length Period Reset Mode Date Auto Scroll Backlight Timeout Runtime Language Voltage Line Current Power Power Factor Energy Demand Status Item Kh Phase Item AI High Value AI Low Value Phase Voltage Line Voltage Active Power Apparent Power Reactive Power 14 Report Daily Report Diagnostic Harmonics Alarm Event Log Analog Input Nameplate Info Run Hour Phasor Today Energy Max/Min Total Power Max/Min V Avg Max/Min I Avg Yesterday Energy Max/Min Total Power Max/Min V Avg Max/Min I Avg This Period Last Reset Va Harmonics Vb Harmonics Vc Harmonics Ia Harmonics Ib Harmonics Ic Harmonics Sag Record Swell Record Alarm Record 15 Chapter 6 Run Time In runtime mode, the instrument is able to measure and store all real time electrical parameters. Following is the table that this instrument can display. 6.1 Display Display Average / ΣResult Phase Voltage Line Voltage Line Current Active Power Apparent Power Reactive Power Power Factor Total Energy Total Energy (Fundamental*、True) Demand* Items Vavg、Iavg、ΣW、ΣVAR L12 、L23 、L31 V, kV, MV L1 、L2 、L3 V, kV, MV L1 、L2 、L3、N A, kA, MA L1、L2、L3、ΣL W, kW, MW L1、L2、L3、ΣL kVA, kVA, MVA L1、L2、L3、ΣL kVAr, kVAr, MVAr L1、L2、L3、ΣL kWh del、rec、total kVARh +(lagging)、- (leading)、total Last kW、kW、Last kVA*、kVA*、 Last kvar*、kvar*、Time Freq: Hz Digital Output 1~2 ON/OFF Digital Input 1~4 ON/OFF Digital Input 5~12 ON/OFF Frequency / Status Frequency / Status *only in advanced modal 6.2 Run Time Auto scroll Each screen except Average/Result can be disable/enable individually in the setup mode, and auto scroll time can be disabled or set from 1 to 6 second. The cruise keys are used to move from one page to another one manually. Use Use to next page to previous page 6.3 Worning for incorrection of wiring or phase “Ø” “△-Y” symbols will be shown on the upper corner of 16 Chapter 7 Set up mode 7.1 Display and keyboard LCD grapic, LED back-lighted, 128 ×128 kWh light:Pulse output Back light:1-99 minute Enter key:Entering setup mode, or confirm the selection Esc key:Back to runtime mode or return to previous setup page Arrow Key:Scroll select item or change the input number or shift input position 17 7.2 Set up Press Enter to setup mode, enter password-xxxxxxx-7 digits,(default as 0000000), user can modify password by:Setup→Basic Setup→Security→Modify pword In Main Menu “Setup”, we have: Clear Function Basic Setup Display Setup 7.2.1 Clear Function Clear function was designed to allow user to easily move and/or reset different data stored in this instrument. Nevertheless, energy data will not be reset due to its accumulation characteristics expect using the function of “energy reset”. In the standard model, to “energy reset” please press the button at the same time at least 5 seconds. Item Setup Daily Reset Energy Reset Sag Reset No Yes Swell Reset Sag/ Swell Reset Alarm Rcd Reset Reset to Default Reset All Demand Reset Period Reset Meter R-Hour Reset Load R-Hour Reset Daily Reset:Clear this Day Max/Min & Yesterday Max/Min Record Energy Reset:Reset kWh_del、kWh_rec、kWh_tot、kWh_net、kVarh_lagging、kVarh_leading、 kVArh_tot、 kVArh_net、kVAh Sag Reset:Reset Sag Record Swell Reset:Reset Swell Record Sag/Swell Reset:Reset Sag/Swell Record Alarm Rcd Reset:Reset Alarm Record 18 Reset to Default:Reset all the parameters to default value Reset All:Clear This Day Max/Min、Yesterday Max/Min 、Energy、Sag、Swell、Alarm、Demand and move This Period Max/Min to Last Reset Max/Min, also recode reset time. Clear This Period Max/Min Demand Reset:Clear Demand data, restart Demand Interval Period Reset:Move This Period Max/Min data to Last Reset Max/Min, record reset time, and clear This Period Max/Min data Meter R-Hour Reset:Clear Meter R-Hour data Load R-Hour Reset:Clear Load R-Hour data 7.2.2 Basic Setup 7.2.2.1 Communication Modbus Please refer to the modbus format and parameters in the chapter 8 Baud Rate:Default is 19200 CM1 Unit ID (1~255):RS485 Modbus ID address, default is 15 Stop Bit:bit to signal the end of communication, depending on PC side. Default is 1 Parity Bit:The total number of bit is always either odd or even, therefore it can be checked during the communication. Default is none Ethernet IP Address:The IP address of SPM-8, “xxx.xxx.xxx.xxx” is required, here xxx is 0-255 Port No.:Port no. has been defined as 502 or 503, please select 502 or 503 Subnet Mask:If subnet was used, host and subnet IP address are required, please use “xxx.xxx.xxx.xxx” to set Gateway:Gateway is used to enter other internet, “xxx.xxx.xxx.xxx” is required Mac Address:It is a fixed number, can not be changed(xx-xx-xx-xx-xx-xx, 0-FF) 19 7.2.2.2 Measurement Volts Mode:If auto is selected, the wiring method will be detected automatically. Default is Auto PT Primary:60~600000(primary voltage) PT Secondary:1~600(secondary voltage) CT Primary:1~5000(primary max. current) CT Secondary:1~5(secondary max. current) Frequency:50 or 60 Hz. Default is 60Hz kWh Direction:Bi-Direction/Single Direction(default) 7.2.2.3 Security If password can not be recalled, please contact your local dealer. You can press “Enter” and “ key” at the same time to reset every parameter to default values including password. The default value of password is “0000000”, 7 digits. Press keys to move the desired position, keys can change the numerical or alphabetic letters in the selected position 7.2.2.4 Alarm Set Point Enable/Disable To enable or disable the alarm setting, if enable is selected, it will be recorded as an event when the alarm was triggered. Sag/Swell Limit Sag Limit Sag limit can be set between 80 to 100%, “%” is the unit used. When measured voltage is lower than the sag limit setting but no longer than 1 min. continuously, it will be treated as “Voltage Sag”. If longer than 1 min., it will be recorded as “Low Voltage”. Use keys to change the setting value. Swell Limit Swell limit will be set between 100~120%. When the measure voltage is high than the swell limit compared to primary voltage setting, for less than 1 min. it is treated as “voltage swell”. If longer than 1 min., it will be recorded as “Over Voltage”. Use keys to chang the setting value. Sag and Swell will be stored in their record, and will not be shown as an alarm event. Ref. Primary Voltage Reference Voltage for sag and swell to compare with. (60~600000) Alarm Set Point 20 Events due to alarm can be read through communication as defined in the following table: Item Description 0x10 Over Current Phase A Alarm 0x11 Over Current Phase B Alarm 0x12 Over Current Phase C Alarm 0x13 Over Current Neutral Alarm 0x14 Current Unbalance Alarm 0x15 Current Loss Alarm 0x20 Over Current Phase A Condition Clear 0x21 Over Current Phase B Condition Clear 0x22 Over Current Phase C Condition Clear 0x23 Over Current Neutral Condition Clear 0x24 Current Unbalance Condition Clear 0x25 Current Loss Condition Clear 0x30 0x31 0x32 0x33 0x34 0x35 0x36 0x37 0x40 0x41 0x42 0x43 0x44 0x45 0x46 0x47 Over Voltage Phase A Alarm Over Voltage Phase B Alarm Over Voltage Phase C Alarm Under Voltage Phase A Alarm Under Voltage Phase B Alarm Under Voltage Phase C Alarm Voltage Unbalance Alarm Voltage Loss Alarm Over Voltage Phase A Condition Clear Over Voltage Phase B Condition Clear Over Voltage Phase C Condition Clear Under Voltage Phase A Condition Clear Under Voltage Phase B Condition Clear Under Voltage Phase C Condition Clear Voltage Unbalance Condition Clear Voltage Loss Condition Clear 0x50 0x51 0x52 0x53 0x54 0x55 0x60 0x61 0x62 0x63 0x64 0x65 THD THD THD THD THD THD THD THD THD THD THD THD 0x70 Over kW Dmd Alarm x80 Over kW Dmd Alarm Condition Clear Va Alarm Vb Alarm Vc Alarm Ia Alarm Ib Alarm Ic Alarm Va Alarm Condition Clear Vb Alarm Condition Clear Vc Alarm Condition Clear Ia Alarm Condition Clear Ib Alarm Condition Clear Ic Alarm Condition Clear 21 V Unbal Alarm The range of V unbal Alarm alarm limit can be set between 0~10%. Comparing voltage of any phase with the average value of all three phase, if the ratio is greater than the set limit, the alarm will be triggered. As the ratio become lower than the set limit, alarm will be cleared. I Unbal Alarm The range of I unbal Alarm alarm limit can be set between 0~10%. Comparing current of any phase with the average value of all three phase, if the ratio is greater than the set limit, the alarm will be triggered. As the ratio become lower than the set limit, alarm will be cleared. V/I THD Alarm Toal harmonic distortion can be set between 0~50%. Over I Phase Alarm The overI phase limit can be set between 0~9999 of primary current. As the current of any phase is over the set limit, alarm triggered. When the over I phase is below the limit, alarm cleared. Over I Neutral Alarm The over I neutral alarm can be set between 0-9999 of primary current. As the I neutral is over the set limit, alarm triggered. When the I neutral is below the set limit, alarm cleared. I Loss Alarm I loss alarm value can be set between 0-5000 of primary current. As only one or two I phase is below the alarm setting value, alarm triggered. However, when all three I phase is either greater or lower than the limit, alarm cleared. V Loss Alarm V loss alarm value can be set between 0-6000 of primary voltage. As only one or two V phase is below the alarm setting value, alarm triggered. However, when all three V phase is either greater or lower than the limit, alarm cleared. Over KW Alarm The demand limit can be set between 0-65535, default value is 0. 7.2.2.5 Clock Setup Date and time will be setup here for use in daily report and regular report and event logging. They will be shown as yy/mm/dd and hh:mm:ss. 7.2.2.6 Digital Output 2 channels of digital output for alarm output and pulse output. Digital Output 1 22 DO1 is desinated as the alarm output, and can be selected from the list Digital Output 2 The output item can be none, kWh, kVARh, kVAh. Pulse output: default is 10(1~6000), equals 1kWh. 7.2.2.7 Analog Output 4 channels of 4-20mA setting, can be assigned to V, I, kW, kVA or kVAR Data measured from secondary V, I, kW, kVA or kVAR;4-20mA are corresponding to the value each items are: Each phase (A,B.C phase): V:0~600V three phase (ΣL): V:0~600V I:0~5A I:0~5A kW:0~3 kWatt kW:0~9 kWatt (total) kvar:0~3 kVAr kvar:0~9 kVAr (total) kVA:0~3 kVA kVA:0~9 kVA (total) For each analog output, users can choose item like V, I and phase like A, B, all. Output(Phase) Once None is chosen, the channel can be used as outpit assigned by communication from upper control software. Output(Item) Selected output item。 7.2.2.8 Analog input AI high value can be from 0-65535, and the corresponding external input is 20mA;low value can be from 0-65535, and the corresponding external value is 4mA. 7.2.2.9 Demand Setup 23 Mode Block Calculation updates at the end of the interval 15-minute interval 15 20 25 15-minute interval 30 35 15-min Time (min) 40 Block Mode Rolling Calculation updates at the end of the subinterval 15-minute interval 15 20 25 30 35 40 45 Time (min) Rolling No. of Subinterval The No. of subinterval is only needed for Rolling mode, can be 1, 2, 3, 4, 5, 6,10,12,15 Subinterval Length Function for both Block and Rolling mode. In block mode, it stands for the total interval time.(No. of subinterval is always 1). In rolling mode, it stands for only lenght of the subinterval time, the total interval time will be No. of subinterval times the subinterval length. 24 7.2.2.10 Period Reset The function of period reset is designed to move the max/min data happened in one current month to last period, and clearn all the max/min data in this month period for the new coming max/min data except the energy data. Energy data will be not reset, instead it will be accumulated. Mode When manual is selected, the reset action will be triggered only the reset all or period reset in clear function has been applied. If auto is selected, users will also be asked to enter the date. The system will perform the move and clear action at the date assigned every month. If date is 2, then at date 2 and 00:00:00 period reset will be excuted. If date is 1, then at date 1 and 00:00:00 period reset will be excuted. If date is 31, then only the month with 31st period reset will be excuted at 31st 00:00:00. However, those months without 31st, period reset will excuted at 1st 00:00:00 next month. 7.2.3 Display Setup Auto Scroll:Can be set between 1-6 sec. or disable. Default is disable. Backlight Timeout:Can be set between 1~99 min. Runtime:This setting allows users to select what to display and not to display during the runtime mode. Run time mode display setting is as following: Language:English Contrast:Can be set between 0-20, default is 10. Item Setup Voltage L-L Voltage L-N Voltage Line Current Active Power Power Apparent Power Reactive Power Power Factor ● Disable ● Enable Energy Demand Status 7.3 Report 25 7.3.1 Daily Report Every day at 00:00:00, data in today will move to yesterday and clear today’s record except energy data will be accumulated. 7.3.2 Diagnostic In this section, only max/ min and when they happened in one month period has been stored. The reset will then move this period data to last reset data and clear this period data except energy data. This Period Item Setup Current Time Date: Time: Max/Min Va Max/Min Vb Max Max/Min Vc Date: Max/Min Ia Time: Max/Min Ib Max/Min Ic Min Max/Min KWa Date: Max/Min KWb Time: Max/Min KWc Max/Min KVAa Max/Min KVAb Max/Min KVAc Min PFa Min Date: Min PFb Time: Min PFc Max VaTHD Max Max VbTHD Date: Max VcTHD Time: Max IaTHD Max IbTHD Max IcTHD Max Demand 26 Last Reset Item Current Time Max/Min Va Max/Min Vb Max/Min Vc Max/Min Ia Max/Min Ib Max/Min Ic Max/Min KWa Max/Min KWb Max/Min KWc Max/Min KVAa Max/Min KVAb Max/Min KVAc Min PFa Min PFb Min PFc Max VaTHD Max VbTHD Max VcTHD Max IaTHD Max IbTHD Max IcTHD Max Demand Energy Setup Date: Time: Max Date: Time: Min Date: Time: Min Date: Time: Max Date: Time: del: rec: tot: 7.3.3 Harmonics Item Va Harmonics Vb Harmonics Vc Harmonics Ia Harmonics Ib Harmonics Ic Harmonics Report Chart 7.3.4 Current on alarm If no current alarm is on, none will be shown. In this instrument up to eight items will be set to alarm as following: V Unbal Alarm I Unbal Alarm THD Alarm I THD Alarm 27 Over V Alarm Under V Alarm Over I Alarm I Loss Alarm V Loss Alarm Over KW Dmd Alarm 7.3.5 Event log In this event log section, up to 20 lastest record has been recorded. 7.3.5.1 Sag Record No:to select the sag record from 1 to 20 using keys Cycle:sag cycles between 0-65535 Data:sag percentage between -327.68%-327.67% Phase:A/B/C phase voltage Begin:begin date and time End:end date and time 7.3.5.2 Swell record No:to select the swell record from 1 to 20 using keys Cycle:swell cycles between 0-65535 Data:swell percentage between -327.68%-327.67% Phase:A/B/C phase voltage Begin:begin date and time End:end date and time 7.3.5.3 Alarm Record No:to select the alarm record from 1 to 20 using keys Item:items can be current voltage…etc., as listed in the table of page 27 Data:percentage between -327.68%-327.67% Date:date of accruing Time:time of accuring 28 7.3.6 Analog Input The AI option was originally setup by entering high value and low value to correspond 4-20mA input. In this report section, users can observe the input data for each channel. 7.3.7 Nameplate Info 7.3.8 Runing Hour Meter Running Hour and Load Running Hour 29 Chapter 8 Communication format 8.1 RS485 8.1.1 RS485 standard PARAMETERS Mode of Operation Number of Drivers and Receives Maximum cable length( meters) Maximum data rate ( baud ) Maximum common mode voltage ( Volts ) Maximum Driver Output Levels ( Loaded ) Maximum Driver Output Levels ( Unloaded ) Drive Load ( Ohms) Driver Output short circuit Resistance ( kohms) Minimum receiver input Resistance ( kohms) Receiver sensitivity Differential 32 Drivers / 32 Receivers 1200 10M 12 to -7 +/- 1.5 +/- 6 60( min ) 150 to Gnd, 250 to -7 or 12V 12 +/- 200mv 8.1.2 Wiring for instruments communication RS485communication must used twisted paired wire, as show in the following program. “D+” connect to one wire and “D-” to the other one Master DD+ Slave D- Slave D+ D- D+ Slave D- D+ 120 ohm 120 ohm Cautions : .There must be no more than two wires connected to each terminal, this ensures that a “Daisy Chain” or “Straight Line” configuration is used. A “star” or a network with “Stubs(Tees)” is not recommended as reflections within the cable may result in data corruption。 30 8.2 Modbus In the start of modus communication, master will issu a “Query” to the slave. Every slaves will monitor the “Query” address, so as to “execute’ or give “response” when the address is right 8.2.1 Modbus Format The Query-Response Cycle Slave 1 Slave 2 Slave 3 Slave n Master Query Response Query message from Master Device Address Device Address Function Code Function Code 8 bit Data Bytes 8 bit Data Bytes Error Check Error Check Response messages from Slave 31 8.3 Communication protocol SPM-8 use Modus RTU as the communication protocol. The following shows Query and Response format. Query: Slave Address Function Code 0x03, 0x04 Response: Slave Function Address Code 0x03, 0x04 Query: Slave Addres s Functio n Code 0x10 Response: Slave Function Address Code 0x10 Start Address (Hi) Byte Count Start Addres s (Hi) Start Address (Lo) Number of Points (Hi) Data (Hi) Data (Lo) Start Address (Lo) Number of Points (Hi) Start Address (Hi) Start Address (Lo) Number of Points (Lo) Error Check (Lo) Number of Points (Lo) Number of Points (Hi) 32 Byte Coun t Number of Points (Lo) Error Check (Lo) Error Check (Hi) Error Check (Hi) Data (Hi) Error Check (Lo) Data (Lo) Error Check (Lo) Error Check (Hi) Error Check (Hi) 8.4 IEEE 754 Format The bits in an IEEE 754 format have the following significance: Data Hi Word, Data Hi Word, Data Lo Word, Data Lo Word, Hi Byte Lo Byte Hi Byte Lo Byte SEEE EEEE EMMM MMMM MMMM MMMM MMMM MMMM Where: S represents the sign bit where 1 is negative and 0 is positive E is the two’s complement exponent with an offset of 127 i.e. an exponent of zero is represented by 127, an exponent of 1 by 128 etc. M is the 23-bit normal mantissa. The highest bit is always 1 and, therefore, is not stored. For each floating point value requested two MODBUS_ registers or points (four bytes) must be requested. The received order and significance of these four bytes for the Integral products is shown below: Data Lo Word, Data Lo Word, Data Hi Word, Data Hi Word, Hi Byte Lo Byte Hi Byte Lo Byte 8.5 Modbus RTU Mode Since Controllers can be setup to communicate on standard Modbus networks using either of two transmission modes:ASCII or RTU. SPM-8 uses RTU transmission mode only. Users select the RTU mode, along with the serial port communication parameters( baud rate, parity mode, etc ), during configuration of each controller. The mode and serial parameters must be the same for all devices on a Modbus connection. RTU Mode Coding System 8-bit binary, hexadecimal 0-9, A-F Bits per Byte 1 8 1 1 Error Check Field Cyclical Redundancy Check(CRC) Two hexadecimal character contained in each 8-bit field of the message start bit data bits, least significant bit sent first bit for even/odd parity;no bit for no parity stop bit if parity is used;2 bits if no parity 33 8.6 Modbus Function Code The function code of a Modbus message defines the action to be taken by the slave. Function code use by SPM-8 is described below: Code Modbus name 03 Read Holding Registers Description Read the content of read/write location ( 4X reference ) 04 Read Input Registers Read the contents of read only location ( 3X reference ) 16 Pre-set Multiple Set the contents of read/write location Registers reference ) Note: The maximum registers of Function 03 &Function 04 is 125 34 ( 4X 8.7 Detail parameter Modbus Module #0 Coil Status : Digital Output Parameter name Digital Output 1 Digital Output 2 Modbus Register 00000 00001 Comment for function code 01: Read Coil Status & 05 : Force Single Coil for function code 01: Read Coil Status & 05 : Force Single Coil Modbus Module #1 Holding Register : Digital Output Modbus Register Parameter name Modicom Format Len Data Type Range Default value bit 0 : Digital Output 1 bit 1 : Digital Output 2 0 Hex Digital Output 44097 0x1000 Word UInt Digital_Output_Reserved 44098 0x1001 Word UInt Units Comment Modbus Module #2 Holding Register : Setup Parameter Modbus Register Parameter name Modicom Format Len Hex Data Type Comm_485_BaudRate 44099 0x1002 Word UInt Comm_485_Address 44100 0x1003 Word UInt Comm_485_StopBit 44101 0x1004 Word UInt Comm_485_Parity 44102 0x1005 Word UInt Reserved Ethernet_IP_0* Ethernet_IP_1* Ethernet_IP_2* Ethernet_IP_3* Ethernet_PortNo* Subnet_Mask_0* Subnet_Mask _1* Subnet_Mask _2* Subnet_Mask _3* Gateway_0* Gateway_1* Gateway_2* Gateway_3* Mac_Address_1* Mac_Address_2* Mac_Address_3* Mac_Address_4* Mac_Address_5* Mac_Address_6* 44103 0x1006 44104 0x1007 44105 0x1008 44106 0x1009 44107 0x100A 44108 0x100B 44109 0x100C 44110 0x100D 44111 0x100E 44112 0x100F 44113 0x1010 Word Hi B Lo B Hi B Lo B Word Hi B Lo B Hi B Lo B Hi B Lo B Hi B Lo B Hi B Lo B Hi B Lo B Hi B Lo B UInt Byte Byte Byte Byte UInt Byte Byte Byte Byte Byte Byte Byte Byte Byte Byte Byte Byte Byte Byte Hi B Byte Lo B Byte DWord Word Word Word Word Word Volts_Mode PT_Primary PT_Secondary CT_Primary CT_Secondary Frequency Demand_Mode* 44114 4411544116 44117 44118 44119 44120 44121 0: 2: 4: 6: 1200 , 1: 2400 , 4800 , 3: 9600 , 19200, 5:38400 57600 1-255 0:1 Stop bit, 1:2 Stop bit 0:No, 1:Even, 2:Odd Default value Units 4 bps 0 0 192 168 1 210 0 255 255 255 0 0 0 0 0 00 18 D8 0 0 0 Float 60-600000 110 Volts UInt UInt UInt UInt UInt 1-600 1-5000 1-5 0:50Hz, 1:60Hz 0:Block, 1:Rolling 110 1 1 1 0 Volts Amp. Amp. 35 Comment 15 0-255 0-255 0-255 0-255 0:502, 1:503 0-255 0-255 0-255 0-255 0-255 0-255 0-255 0-255 0-ffh 0-ffh 0-ffh 0-ffh 0-ffh 0-ffh Volts Mode at present 0 : 1P2W , 1 : 1P3W , 2 : 3P3W_Delta 2CT, 3 : 3P3W_Delta 3CT, 4 : 3P4W_Wye , 5 : Auto 0x1011 0x10120x1013 0x1014 0x1015 0x1016 0x1017 0x1018 Range optional optional optional optional optional optional optional optional optional optional optional optional optional optional optional optional optional optional optional 5 1,2,3,4,5,6,10,12,1 5 1,2,3,4,5,6,10,12,1 5,20,30,60 1 Number_of_Subinterval* 44122 0x1019 Word UInt Demand_Subinterval_ Length* 44123 0x101A Word UInt Password 4412444125 0x101B0x101C DWord Uint3 2 0xxxxxxxh Over_kW_Dmd_Limit* 44126 0x101D Word UInt 0-65535 65535 kW. Over_kW_Dmd_Clear* 44127 0x101E Word UInt 0-65535 0 kW. Alarm_Enable 44128 0x101F Word UInt 0 : disable , 1 : enable 0 SAG_Limit 44129 0x1020 Word UInt Range : 80% 100% 100 % SWELL_Limit 44130 0x1021 Word UInt Range : 100% 120% 100 % Reference_Primary_Volta ge 4413144132 0x10220x1023 DWord Float 60-600000 110 Volts Voltage_Unbal_Limit 44133 0x1024 Word UInt Range : 0% - 10% 10 % Current_Unbal_Limit 44134 0x1025 Word UInt Range : 0% - 10% 10 % Hi B Byte Range : 0% - 50% 50 % 44135 0x1026 Lo B Byte Range : 0% - 50% 50 % I_THD_Limit* V_THD_Limit* 15 Min 0000000 Over_Current_Phase_Li mit 44136 0x1027 Word UInt 0-9999 9999 Amp. Over_Current_Neutral _Limit 44137 0x1028 Word UInt 0-9999 9999 Amp. Current_Loss_Limit 44138 0x1029 Word UInt 0-5000 0 Amp. Voltage_Loss_Limit 4413944140 0x102A DWord Float 0-600000 0 Volts Voltage_Unbal_Clear 44141 0x102B Word UInt Range : 0% - 10% 1 % Current_Unbal_ Clear 44142 0x102C Word UInt Range : 0% - 10% 1 % Hi B Byte Range : 0% - 50% 1 % 44143 0x102D Lo B Byte Range : 0% - 50% 1 % I_THD_ Clear* V_THD_ Clear* Over_Current_Phase_ Clear 44144 0x102E Word UInt 0-9999 0 Amp. Over_Current_Neutral _ Clear 44145 0x102F Word UInt 0-9999 0 Amp. Current_Loss_ Clear 44146 0x1030 Word UInt 0-5000 0 Amp. Voltage_Loss_ Clear 4414744148 0x10310x1032 DWord Float 0-600000 0 Volts 36 For Over kW Dmd alarm For Over kW Dmd alarm clear For Sag & UnderVoltag e alarm For Swell & OverVoltage alarm For Sag/Swell & Under/Over Voltage For Voltage unbalance alarm For Current unbalance alarm For I THD alarm For V THD alarm For Over Current Phase alarm For Over Current Neutral alarm For Phase Loss-Current alarm For Phase Loss-Voltage alarm For Voltage unbalance alarm clear For Current unbalance alarm clear For I THD alarm For V THD alarm clear For Over Current Phase alarm clear For Over Current Neutral alarm clear For Phase Loss-Current alarm clear For Phase Loss-Voltage alarm clear 0 : None 1 : Voltage unbalance alarm 2 : Current unbalance alarm 3 : Over Voltage alarm 4 : Under Voltage alarm 5 : Over Current alarm 6 : Current Loss alarm 7 : Voltage Loss alarm 8 : Any 0 : None 1 : Voltage unbalance alarm 2 : Current unbalance alarm 3 : V THD alarm* 4 : Over Voltage alarm 5 : Under Voltage alarm 6 : Over Current alarm 7 : Current Loss alarm 8 : Voltage Loss alarm 9 : Over kW Dmd alarm* 10: I THD alarm* 11: Any 0 for standard 0 for advance DO1_Select_Item 44149 0x1033 Word Uint DO1_Select_Item* 44149 0x1034 Word Uint 44150 0x1035 Hi B Byte Reserved Lo B Byte AO1_Select_Phase Hi B Byte 0:None, 1:A phase, 2:B phase, 3:C phase, 4:Total 0 optional AO1_Select_ Item Lo B Byte 0:V, 1:I , 2:kW , 3:kvar, 4:kVA 0 optional AO2_Select_Phase Hi B Byte 0:None, 1:A phase, 2:B phase, 3:C phase, 4:Total 0 optional AO2_Select_ Item Lo B Byte 0:V, 1:I , 2:kW , 3:kvar, 4:kVA 0 optional AO3_Select_Phase Hi B Byte 0:None, 1:A phase, 2:B phase, 3:C phase, 4:Total 0 optional AO3_Select_ Item Lo B Byte 0:V, 1:I , 2:kW , 3:kvar, 4:kVA 0 optional AO4_Select_Phase Hi B Byte 0:None, 1:A phase, 2:B phase, 3:C phase, 4:Total 0 optional Lo B Byte 0:V, 1:I , 2:kW , 3:kvar, 4:kVA 0 optional Word Hi B Lo B UInt Byte Byte 0 - 6 sec 1 - 99 min 0 1 DO2_Select_Item 44151 44152 44153 44154 0x1036 0x1037 0x1038 0x1039 AO4_Select_ Item Reserved Display_Auto_Scroll Display_BK_Timeout 44155 0x103A 44156 0x103B 37 0 : None , 1 : kWh 2 : kvarh , 3 : kVAh 0 0 Runtime_Screen_Set 44157 0x103C Word UInt Byte Byte UInt UInt UInt UInt UInt UInt UInt UInt UInt UInt UInt UInt UInt UInt UInt Reset_Mode* Reset_Date* Reserved AI1_Eng_High AI1_Eng_Low AI2_Eng_High AI2_Eng_Low AI3_Eng_High AI3_Eng_Low AI4_Eng_High AI4_Eng_Low Reserved Reserved AO1_Set_Value AO2_Set_Value AO3_Set_Value AO4_Set_Value 44158 0x103D 44159 44160 44161 44162 44163 44164 44165 44166 44167 44168 44169 44170 44171 44172 44173 0x103E 0x103F 0x1040 0x1041 0x1042 0x1043 0x1044 0x1045 0x1046 0x1047 0x1048 0x1049 0x104A 0x104B 0x104C Hi B Lo B Word Word Word Word Word Word Word Word Word Word Word Word Word Word Word Language 44174 0x104D Word UInt kWh_Direction 44175 0x104E Word UInt Contrast 44176 0x104F Word UInt Bit=0 : Disable Bit=1 : Enable bit 0 : Phase Voltage bit 1 : Line Voltage bit 2 : Line Current bit 3 : Active Power bit 4 : Apparent Power bit 5 : Reactive Power bit 6 : Power Factor bit 7 : Energy bit 8 : Demand* bit 9 : Status 0:Manual, 1:Auto 1~31 0~65535 0~65535 0~65535 0~65535 0~65535 0~65535 0~65535 0~65535 0~65535 0~65535 0~65535 0~65535 0 : English 1 : Secondary Language 0 : Single direction 1 : Bi-direction 0 ~20 2ff/3ff 0 1 65535 0 65535 0 65535 0 65535 0 optional optional optional optional optional optional optional optional 0 0 0 0 optional optional optional optional 1 0: SPM-8-0 1: SPM-8-1 10 Modbus Module #2-1 Holding Register : Setup Parameter Modbus Register Parameter name AO_Wtot_High_Limit Modicom Format 44300 Len Data Type Word UInt Hex 0x10CB Default value Units 9000 W Range Default value Units 1200 , 1: 2400 , 4800 , 3: 9600 , 19200, 5:38400 57600 4 bps Range 0~9000 Comment secondary Modbus Module #2-2 Holding Register : Setup Parameter Modbus Register Parameter name Modico m Format Len Hex Data Type Snd_485_BaudRate* 44353 0x1100 Word UInt 0: 2: 4: 6: Snd_485_Address* 44354 0x1101 Word UInt 1-255 Snd_485_StopBit* 44355 0x1102 Word UInt 0:1 Stop bit, 1:2 Stop bit 0 Snd_485_Parity* 44356 0x1103 Word UInt 0:No, 1:Even, 2:Odd 0 DO2_Select_Kh 44357 0x1104 Word UInt 1-6000 Comment 16 10 Modbus Module #3 Holding Register : Realtime Clock Parameter name Modbus Register Len Data Type 38 Range Default value Units Comment Year Month Date Hour Min Second Modicom Format 44177 44178 44179 44180 44181 44182 Hex 0x1050 0x1051 0x1052 0x1053 0x1054 0x1055 Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD Modbus Module #4 Holding Register : Clear Function Modbus Register Parameter name Reset_ Daily* Reset_ Energy Reset _Sag _Record* Reset_Swell_Record* Reset_Sag_Swell_Record * Reset_Alarm_Record* Reset_to_Default Reset_All* Reset_Demand* Period_Reset* Len Data Type Range Default value 0x1060 0x1061 0x1062 0x1063 Word Word Word Word UInt Uint Uint Uint 0x5aa5 0x5aa5 0x5aa5 0x5aa5 0 0 0 0 0x5aa5: 0x5aa5: 0x5aa5: 0x5aa5: 44197 0x1064 Word Uint 0x5aa5 0 0x5aa5: clear 44198 44199 44200 44201 44202 0x1065 0x1066 0x1067 0x1068 0x1069 Word Word Word Word Word Uint Uint Uint Uint Uint 0x5aa5 0x5aa5 0x5aa5 0x5aa5 0x5aa5 0 0 0 0 0 0x5aa5: 0x5aa5: 0x5aa5: 0x5aa5: 0x5aa5: Modicom Format 44193 44194 44195 44196 Hex Units Comment clear clear clear clear clear clear clear clear clear Modbus Module #5 Holding Register : Alarm Counter* Modbus Register Len Data Type Range 0x1070 0x1071 0x1072 Word Word Word Uint Uint Uint 0-20 0-20 0-20 44212 0x1073 Word Uint 0-20 Sag_Total_Counter 44213 0x1074 Word Uint 0-20 Swell_Total_Counter 44214 0x1075 Word Uint 0-20 Parameter name Alarm_New_Counter Sag_New_Counter Swell_New_Counter Modicom Format 44209 44210 44211 Alarm_Total_Counter Hex Default value Units Comment Current total accumulates(up to 20 data) Current total accumulates(up to 20 data) Current total accumulates(up to 20 data) Modbus Module #6 Input Register : Digital Output Modbus Register Parameter name Modicom Format Len Data Type Range Default value bit 0 : Digital Output 1 bit 1 : Digital Output 2 0 Hex Digital Output 34097 0x1000 Word UInt Digital_Output_Reserved 34098 0x1001 Word UInt Units Comment Units Comment Modbus Module #7 Input Register : Digital Intput Modbus Register Parameter name Digital Input Modicom Format 34099 Len Hex 0x1002 Word Data Type UInt 39 Default value Range bit bit bit bit bit bit bit bit bit bit 0 1 2 3 4 5 6 7 8 9 : : : : : : : : : : Digital Digital Digital Digital Digital Digital Digital Digital Digital Digital Input Input Input Input Input Input Input Input Input Input 1 2 3 4 5 6 7 8 9 10 bit 10 : Digital Input 11 bit 11 : Digital Input 12 Digital_Input_Reserved 34100 0x1003 Word UInt Modbus Module #8 Input Register : Alarm Counter* Modbus Register Len Data Type Range 0x1004 0x1005 0x1006 Word Word Word UInt UInt UInt 0-20 0-20 0-20 34104 0x1007 Word UInt 0-20 Sag_Total_Counter 34105 0x1008 Word UInt 0-20 Swell_Total_Counter 34106 0x1009 Word UInt 0-20 Parameter name Alarm_New_Counter Sag_New_Counter Swell_New_Counter Modicom Format 34101 34102 34103 Alarm_Total_Counter Hex Default value Units Comment Current total accumulates(up to 20 data) Current total accumulates(up to 20 data) Current total accumulates(up to 20 data) Modbus Module #9 Input Register : Realtime Data Voltage, Current, Frequency (Float) Modbus Register Parameter name Vln_a Vln_b Vln_c Vln_avg Vll_ab Vll_bc Vll_ca Vll_avg I_a I_b I_c I_avg I_n Freq Modicom Format 3410734108 3410934110 3411134112 3411334114 3411534116 3411734118 3411934120 3412134122 3412334124 3412534126 3412734128 3412934130 3413134132 3413334134 Data Type Range DWord Float Primary Voltage Volts DWord Float Primary Voltage Volts DWord Float Primary Voltage Volts DWord Float Primary Voltage Volts DWord Float Primary Voltage Volts DWord Float Primary Voltage Volts DWord Float Primary Voltage Volts DWord Float Primary Voltage Volts DWord Float Primary Current Amp. DWord Float Primary Current Amp. DWord Float Primary Current Amp. DWord Float Primary Current Amp. DWord Float Primary Current Amp. DWord Float Hex 0x100A0x100B 0x100C0x100D 0x100E0x1000F 0x10100x1011 0x10120x1013 0x10140x1015 0x10160x1017 0x10180x1019 0x101A0x101B 0x101C0x101D 0x101E0x101F 0x10200x1021 0x10220x1023 0x10240x1025 Default value Len Units Hz Comment with Runtime display with Runtime display with Runtime display with Runtime display with Runtime display with Runtime display with Runtime display with Runtime display with Runtime display with Runtime display with Runtime display with Runtime display with Runtime display with Runtime display Modbus Module #10 Input Register : Realtime Data Power Result (Float) Modbus Register Parameter name KW_a KW_b KW_c KW_tot KVAR_a Modicom Format 3413534136 3413734138 3413934140 3414134142 34143- Len Data Type DWord Float DWord Float DWord Float DWord Float DWord Float Hex 0x10260x1027 0x10280x1029 0x102A0x102B 0x102C0x102D 0x102E- 40 Range Default value Units Comment with Runtime display with Runtime display with Runtime display with Runtime display with Runtime KVAR_b KVAR_c KVAR_tot KVA_a KVA_b KVA_c KVA_tot 34144 3414534146 3414734148 3414934150 3415134152 3415334154 3415534156 3415734158 0x102F 0x10300x1031 0x10320x1033 0x10340x1035 0x10360x1037 0x10380x1039 0x103A0x103B 0x103C0x103D DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float display with Runtime display with Runtime display with Runtime display with Runtime display with Runtime display with Runtime display with Runtime display Modbus Module #11 Input Register : Realtime Data Power Factor(True) & Phase Angle (Float) Modbus Register Parameter name PF_true_a PF_true_b PF_true_c PF_true_avg PhaseAngle_V_a PhaseAngle_V_b PhaseAngle_V_c PhaseAngle_I_a PhaseAngle_I_b PhaseAngle_I_c Pre_Demand_KW* Reserved Reserved Modicom Format 3415934160 3416134162 3416334164 3416534166 3416734168 3416934170 3417134172 3417334174 3417534176 3417734178 3417934180 3418134182 3418334184 Len Hex 0x103E0x103F 0x10400x1041 0x10420x1043 0x10440x1045 0x10460x1047 0x10480x1049 0x104A0x104B 0x104C0x104D 0x104E0x104F 0x10500x1051 0x10520x1053 0x10540x1055 0x10560x1057 Data Type DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float Range Default value Units Comment with Runtime display with Runtime display with Runtime display with Runtime display with Runtime display Modbus Module #12 Input Register : Realtime Data Energy (Float) Modbus Register Parameter name KWH_del KWH_rec KWH_tot KWH_net KVARH_ lagging KVARH_ leading KVARH_tot Modicom Format 3418534186 3418734188 3418934190 3419134192 3419334194 3419534196 3419734198 Len Data Type DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float Hex 0x10580x1059 0x105A0x105B 0x105C0x105D 0x105E0x105F 0x10600x1061 0x10620x1063 0x10640x1065 41 Range Default value Units Comment with Runtime display with Runtime display with Runtime display with Runtime display with Runtime display with Runtime display with Runtime display KVARH_net KVAH 3419934200 3420134202 0x10660x1067 0x10680x1069 DWord Float DWord Float with Runtime display Modbus Module #13 Input Register : Realtime data Demand-1* Modbus Register Parameter name Demand_KW* Demand_Remain_Time* Modicom Format 3420334204 34205 Len Data Type DWord Float Word UInt Hex 0x106A0x106B 0x106C Range Default value Units Comment sec Modbus Module #14 Input Register : AI Result(optional) Modbus Register Parameter name Modicom Format Len Hex Data Type Range AI1 Value 34206 0x106D Word UInt 0~65535 AI2 Value 34207 0x106E Word UInt 0~65535 AI3 Value 34208 0x106F Word UInt 0~65535 AI4 Value 34209 0x1070 Word UInt 0~65535 Default value Units Comment Default value Units Comment Modbus Module #15 Input Register : Fundamental PF* Modbus Register Parameter name PF_Fundamental_a PF_Fundamental_b PF_Fundamental_c PF_Fundamental_d Modicom Format 3421034211 3421234213 3421434215 3421634217 Len Data Type DWord Float DWord Float DWord Float DWord Float Hex 0x10710x1072 0x10730x1074 0x10750x1076 0x10770x1078 Range with Runtime display with Runtime display with Runtime display with Runtime display Modbus Module #13-1 Input Register : Realtime data Demand-2* Modbus Register Parameter name Pre_Demand_kW Demand_kW Pre_Demand_kvar Demand_kvar Pre_Demand_kVA Demand_kVA Demand_Remain_Time Modicom Format 3422234223 3422434225 3422634227 3422834229 3423034231 3423234233 34234 Len Data Type DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float Word UInt Hex 0x107D0x107E 0x107F0x1080 0x10810x1082 0x10830x1084 0x10850x1086 0x10870x1088 0x1089 Range Default value Units Comment sec Modbus Module #16-1 Input Register : kWh used Report * Parameter name Modbus Register Len Data Type 42 Range Default value Units Comment KWH_used_Yesterday KWH_used_LastReset Modicom Format 3460534606 3460734608 Hex 0x11FC0x11FD 0x11FE0x11FF DWord Float DWord Float Modbus Module #16 Input Register : Daily Report This Day Max/Min* Modbus Register Parameter name KWH_del_DT KWH_rec_DT KWH_tot_DT KW_tot_max_DT KW_tot_max_DT_Year KW_tot_max_DT_Month KW_tot_max_DT_Date KW_tot_max_DT_Hour KW_tot_max_DT_Min KW_tot_max_DT_Second KW_tot_min_DT KW_tot_min_DT_Year KW_tot_min_DT_Month KW_tot_min_DT_Date KW_tot_min_DT_Hour KW_tot_min_DT_Min KW_tot_min_DT_Second Vavg_max_DT Vavg_max_DT_Year Vavg_max_DT_Month Vavg_max_DT_Date Vavg_max_DT_Hour Vavg_max_DT_Min Vavg_max_DT_Second Vavg_min_DT Vavg_min_DT_Year Vavg_min_DT_Month Vavg_min_DT_Date Vavg_min_DT_Hour Vavg_min_DT_Min Vavg_min_DT_Second Iavg_max_DT Iavg_max_DT_Year Iavg_max_DT_Month Iavg_max_DT_Date Iavg_max_DT_Hour Iavg_max_DT_Min Iavg_max_DT_Second Iavg_min_DT Iavg_min_DT_Year Iavg_min_DT_Month Iavg_min_DT_Date Iavg_min_DT_Hour Iavg_min_DT_Min Iavg_min_DT_Second Demand_max_DT Demand_max_DT_Year Modicom Format 3460934610 3461134612 3461334614 3461534616 34617 34618 34619 34620 34621 34622 3462334624 34625 34626 34627 34628 34629 34630 3463134632 34633 34634 34635 34636 34637 34638 3463934640 34641 34642 34643 34644 34645 34646 3464734648 34649 34650 34651 34652 34653 34654 3465534656 34657 34658 34659 34660 34661 34662 3466334664 34665 Len Data Type DWord Float DWord Float DWord Float DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word BCD Hex 0x12000x1201 0x12020x1203 0x12040x1205 0x12060x1207 0x1208 0x1209 0x120A 0x120B 0x120C 0x120D 0x120E0x120F 0x1210 0x1211 0x1212 0x1213 0x1214 0x1215 0x12160x1217 0x1218 0x1219 0x121A 0x121B 0x121C 0x121D 0x121E0x121F 0x1220 0x1221 0x1222 0x1223 0x1224 0x1225 0x12260x1227 0x1228 0x1229 0x122A 0x122B 0x122C 0x122D 0x122E0x122F 0x1230 0x1231 0x1232 0x1233 0x1234 0x1235 0x12360x1237 0x1238 43 Range 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 Default value Units Comment Demand_max_DT_Month Demand_max_DT_Date Demand_max_DT_Hour Demand_max_DT_Min Demand_max_DT_Secon d 34666 34667 34668 34669 0x1239 0x123A 0x123B 0x123C Word Word Word Word BCD BCD BCD BCD 1-12 1-31 0-23 0-59 34670 0x123D Word BCD 0-59 Modbus Module #17 Input Register : Daily Report Yesterday Max/Min* Modbus Register Parameter name KWH_del_DY KWH_rec_DY KWH_tot_DY KW_tot_max_DY KW_tot_max_DY_Year KW_tot_max_DY_Month KW_tot_max_DY_Date KW_tot_max_DY_Hour KW_tot_max_DY_Min KW_tot_max_DY_Secon d KW_tot_min_DY KW_tot_min_DY_Year KW_tot_min_DY_Month KW_tot_min_DY_Date KW_tot_min_DY_Hour KW_tot_min_DY_Min KW_tot_min_DY_Second Vavg_max_DY Vavg_max_DY_Year Vavg_max_DY_Month Vavg_max_DY_Date Vavg_max_DY_Hour Vavg_max_DY_Min Vavg_max_DY_Second Vavg_min_DY Vavg_min_DY_Year Vavg_min_DY_Month Vavg_min_DY_Date Vavg_min_DY_Hour Vavg_min_DY_Min Vavg_min_DY_Second Iavg_max_DY Iavg_max_DY_Year Iavg_max_DY_Month Iavg_max_DY_Date Iavg_max_DY_Hour Iavg_max_DY_Min Iavg_max_DY_Second Iavg_min_DY Iavg_min_DY_Year Iavg_min_DY_Month Iavg_min_DY_Date Iavg_min_DY_Hour Iavg_min_DY_Min Iavg_min_DY_Second Demand_max_DY Modicom Format 3467134672 3467334674 3467534676 3467734678 34679 34680 34681 34682 34683 0x123E0x123F 0x12400x1241 0x12420x1243 0x12440x1245 0x1246 0x1247 0x1248 0x1249 0x124A 34684 0x124B 3468534686 34687 34688 34689 34690 34691 34692 3469334694 34695 34696 34697 34698 34699 34700 3470134702 34703 34704 34705 34706 34707 34708 3470934710 34711 34712 34713 34714 34715 34716 3471734718 34719 34720 34721 34722 34723 34724 3472534726 0x124C0x124D 0x124E 0x124F 0x1250 0x1251 0x1252 0x1253 0x12540x1255 0x1256 0x1257 0x1258 0x1259 0x125A 0x125B 0x125C0x125D 0x125E 0x125F 0x1260 0x1261 0x1262 0x1263 0x12640x1265 0x1266 0x1267 0x1268 0x1269 0x126A 0x126B 0x126C0x126D 0x126E 0x126F 0x1270 0x1271 0x1272 0x1273 0x12740x1275 Len Data Type DWord Float DWord Float DWord Float DWord Float Word Word Word Word Word BCD BCD BCD BCD BCD 00-99 1-12 1-31 0-23 0-59 Word BCD 0-59 DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Hex 44 Range 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 Default value Units Comment Demand_max_DY_Year Demand_max_DY_Month Demand_max_DY_Date Demand_max_DY_Hour Demand_max_DY_Min Demand_max_DY_Secon d 34727 34728 34729 34730 34731 0x1276 0x1277 0x1278 0x1279 0x127A Word Word Word Word Word BCD BCD BCD BCD BCD 00-99 1-12 1-31 0-23 0-59 34732 0x127B Word BCD 0-59 Modbus Module #18 Input Register : Diagnostic This Period Max/Min* Modbus Register Parameter name Va_max_TP Va_max_TP_Year Va_max_TP_Month Va_max_TP_Date Va_max_TP_Hour Va_max_TP_Min Va_max_TP_Second Va_min_TP Va_min_TP_Year Va_min_TP_Month Va_min_TP_Date Va_min_TP_Hour Va_min_TP_Min Va_min_TP_Second Vb_max_TP Vb_max_TP_Year Vb_max_TP_Month Vb_max_TP_Date Vb_max_TP_Hour Vb_max_TP_Min Vb_max_TP_Second Vb_min_TP Vb_min_TP_Year Vb_min_TP_Month Vb_min_TP_Date Vb_min_TP_Hour Vb_min_TP_Min Vb_min_TP_Second Vc_max_TP Vc_max_TP_Year Vc_max_TP_Month Vc_max_TP_Date Vc_max_TP_Hour Vc_max_TP_Min Vc_max_TP_Second Vc_min_TP Vc_min_TP_Year Vc_min_TP_Month Vc_min_TP_Date Vc_min_TP_Hour Vc_min_TP_Min Vc_min_TP_Second Ia_max_TP Ia_max_TP_Year Ia_max_TP_Month Ia_max_TP_Date Ia_max_TP_Hour Ia_max_TP_Min Modicom Format 3473334734 34735 34736 34737 34738 34739 34740 3474134742 34743 34744 34745 34746 34747 34748 3474934750 34751 34752 34753 34754 34755 34756 3475734758 34759 34760 34761 34762 34763 34764 3476534766 34767 34768 34769 34770 34771 34772 3477334774 34775 34776 34777 34778 34779 34780 3478134782 34783 34784 34785 34786 34787 Len Data Type DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word BCD BCD BCD BCD BCD Hex 0x127C0x127D 0x127E 0x127F 0x1280 0x1281 0x1282 0x1283 0x12840x1285 0x1286 0x1287 0x1288 0x1289 0x128A 0x128B 0x128C0x128D 0x128E 0x128F 0x1290 0x1291 0x1292 0x1293 0x12940x1295 0x1296 0x1297 0x1298 0x1299 0x129A 0x129B 0x129C0x129D 0x129E 0x129F 0x12A0 0x12A1 0x12A2 0x12A3 0x12A40x12A5 0x12A6 0x12A7 0x12A8 0x12A9 0x12AA 0x12AB 0x12AC0x12AD 0x12AE 0x12AF 0x12B0 0x12B1 0x12B2 45 Range 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 Default value Units Comment Ia_max_TP_Second Ia_min_TP Ia_min_TP_Year Ia_min_TP_Month Ia_min_TP_Date Ia_min_TP_Hour Ia_min_TP_Min Ia_min_TP_Second Ib_max_TP Ib_max_TP_Year Ib_max_TP_Month Ib_max_TP_Date Ib_max_TP_Hour Ib_max_TP_Min Ib_max_TP_Second Ib_min_TP Ib_min_TP_Year Ib_min_TP_Month Ib_min_TP_Date Ib_min_TP_Hour Ib_min_TP_Min Ib_min_TP_Second Ic_max_TP Ic_max_TP_Year Ic_max_TP_Month Ic_max_TP_Date Ic_max_TP_Hour Ic_max_TP_Min Ic_max_TP_Second Ic_min_TP Ic_min_TP_Year Ic_min_TP_Month Ic_min_TP_Date Ic_min_TP_Hour Ic_min_TP_Min Ic_min_TP_Second KWa_max_TP KWa_max_TP_Year KWa_max_TP_Month KWa_max_TP_Date KWa_max_TP_Hour KWa_max_TP_Min KWa_max_TP_Second KWa_min_TP KWa_min_TP_Date KWa_min_TP_Month KWa_min_TP_Date KWa_min_TP_Hour KWa_min_TP_Min KWa_min_TP_Second KWb_max_TP KWb_max_TP_Year KWb_max_TP_Month KWb_max_TP_Date KWb_max_TP_Hour KWb_max_TP_Min KWb_max_TP_Second KWb_min_TP KWb_min_TP_Year KWb_min_TP_Month KWb_min_TP_Date 34788 3478934790 34791 34792 34793 34794 34795 34796 3479734798 34799 34800 34801 34802 34803 34804 3480534806 34807 34808 34809 34810 34811 34812 3481334814 34815 34816 34817 34818 34819 34820 3482134822 34823 34824 34825 34826 34827 34828 3482934830 34831 34832 34833 34834 34835 34836 3483734838 34839 34840 34841 34842 34843 34844 3484534846 34847 34848 34849 34850 34851 34852 3485334854 34855 34856 34857 0x12B3 0x12B40x12B5 0x12B6 0x12B7 0x12B8 0x12B9 0x12BA 0x12BB 0x12BC0x12BD 0x12BE 0x12BF 0x12C0 0x12C1 0x12C2 0x12C3 0x12C40x12C5 0x12C6 0x12C7 0x12C8 0x12C9 0x12CA 0x12CB 0x12CC0x12CD 0x12CE 0x12CF 0x12D0 0x12D1 0x12D2 0x12D3 0x12D40x12D5 0x12D6 0x12D7 0x12D8 0x12D9 0x12DA 0x12DB 0x12DC0x12DD 0x12DE 0x12DF 0x12E0 0x12E1 0x12E2 0x12E3 0x12E40x12E5 0x12E6 0x12E7 0x12E8 0x12E9 0x12EA 0x12EB 0x12EC0x12ED 0x12EE 0x12EF 0x12F0 0x12F1 0x12F2 0x12F3 0x12F40x12F5 0x12F6 0x12F7 0x12F8 Word BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word BCD BCD BCD 46 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 KWb_min_TP_Hour KWb_min_TP_Min KWb_min_TP_Second KWc_max_TP KWc_max_TP_Year KWc_max_TP_Month KWc_max_TP_Date KWc_max_TP_Hour KWc_max_TP_Min KWc_max_TP_Second KWc_min_TP KWc_min_TP_Year KWc_min_TP_Month KWc_min_TP_Date KWc_min_TP_Hour KWc_min_TP_Min KWc_min_TP_Second KVAa_max_TP KVAa_max_TP_Year KVAa_max_TP_Month KVAa_max_TP_Date KVAa_max_TP_Hour KVAa_max_TP_Min KVAa_max_TP_Second KVAa_min_TP KVAa_min_TP_Year KVAa_min_TP_Month KVAa_min_TP_Date KVAa_min_TP_Hour KVAa_min_TP_Min KVAa_min_TP_Second KVAb_max_TP KVAb_max_TP_Year KVAb_max_TP_Month KVAb_max_TP_Date KVAb_max_TP_Hour KVAb_max_TP_Min KVAb_max_TP_Second KVAb_min_TP KVAb_min_TP_Year KVAb_min_TP_Month KVAb_min_TP_Date KVAb_min_TP_Hour KVAb_min_TP_Min KVAb_min_TP_Second KVAc_max_TP KVAc_max_TP_Year KVAc_max_TP_Month KVAc_max_TP_Date KVAc_max_TP_Hour KVAc_max_TP_Min KVAc_max_TP_Second KVAc_min_TP KVAc_min_TP_Year KVAc_min_TP_Month KVAc_min_TP_Date KVAc_min_TP_Hour KVAc_min_TP_Min KVAc_min_TP_Second PFa_min_TP PFa_min_TP_Year 34858 34859 34860 3486134862 34863 34864 34865 34866 34867 34868 3486934870 34871 34872 34873 34874 34875 34876 3487734878 34879 34880 34881 34882 34883 34884 3488534886 34887 34888 34889 34890 34891 34892 3489334894 34895 34896 34897 34898 34899 34900 3490134902 34903 34904 34905 34906 34907 34908 3490934910 34911 34912 34913 34914 34915 34916 3491734918 34919 34920 34921 34922 34923 34924 3492534926 34927 0x12F9 0x12FA 0x12FB 0x12FC0x12FD 0x12FE 0x12FF 0x1300 0x1301 0x1302 0x1303 0x13040x1305 0x1306 0x1307 0x1308 0x1309 0x130A 0x130B 0x130C0x130D 0x130E 0x130F 0x1310 0x1311 0x1312 0x1313 0x13140x1315 0x1316 0x1317 0x1318 0x1319 0x131A 0x131B 0x131C0x131D 0x131E 0x131F 0x1320 0x1321 0x1322 0x1323 0x13240x1325 0x1326 0x1327 0x1328 0x1329 0x132A 0x132B 0x132C0x132D 0x132E 0x132F 0x1330 0x1331 0x1332 0x1333 0x13340x1335 0x1336 0x1337 0x1338 0x1339 0x133A 0x133B 0x133C0x133D 0x133E Word Word Word BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word BCD 47 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 PFa_min_TP_Month PFa_min_TP_Date PFa_min_TP_Hour PFa_min_TP_Min PFa_min_TP_Second PFb_min_TP PFb_min_TP_Year PFb_min_TP_Month PFb_min_TP_Date PFb_min_TP_Hour PFb_min_TP_Min PFb_min_TP_Second PFc_min_TP PFc_min_TP_Year PFc_min_TP_Month PFc_min_TP_Date PFc_min_TP_Hour PFc_min_TP_Min PFc_min_TP_Second VaTHD_max_TP VaTHD_max_TP_Year VaTHD_max_TP_Month VaTHD_max_TP_Date VaTHD_max_TP_Hour VaTHD_max_TP_Min VaTHD_max_TP_Second VbTHD_max_TP VbTHD_max_TP_Year VbTHD_max_TP_Month VbTHD_max_TP_Date VbTHD_max_TP_Hour VbTHD_max_TP_Min VbTHD_max_TP_Second VcTHD_max_TP VcTHD_max_TP_Year VcTHD_max_TP_Month VcTHD_max_TP_Date VcTHD_max_TP_Hour VcTHD_max_TP_Min VcTHD_max_TP_Second IaTHD_max_TP IaTHD_max_TP_Year IaTHD_max_TP_Month IaTHD_max_TP_Date IaTHD_max_TP_Hour IaTHD_max_TP_Min IaTHD_max_TP_Second IbTHD_max_TP IbTHD_max_TP_Year IbTHD_max_TP_Month IbTHD_max_TP_Date IbTHD_max_TP_Hour IbTHD_max_TP_Min IbTHD_max_TP_Second IcTHD_max_TP IcTHD_max_TP_Year IcTHD_max_TP_Month IcTHD_max_TP_Date IcTHD_max_TP_Hour IcTHD_max_TP_Min IcTHD_max_TP_Second Demand_max_TP 34928 34928 34930 34931 34932 3493334934 34935 34935 34937 34938 34939 34940 3494134942 34943 34944 34945 34946 34947 34948 3494934950 34951 34952 34953 34954 34955 34956 3495734958 34959 34960 34961 34962 34963 34964 3496534966 34967 34968 34969 34970 34971 34972 3497334974 34975 34976 34977 34978 34979 34980 3498134982 34983 34984 34985 34986 34987 34988 3498934990 34991 34992 34993 34994 34995 34996 34997- 0x133F 0x1340 0x1341 0x1342 0x1343 0x13440x1345 0x1346 0x1347 0x1348 0x1349 0x134A 0x134B 0x134C0x134D 0x134E 0x134F 0x1350 0x1351 0x1352 0x1353 0x13540x1355 0x1356 0x1357 0x1358 0x1359 0x135A 0x135B 0x135C0x135D 0x135E 0x135F 0x1360 0x1361 0x1362 0x1363 0x13640x1365 0x1366 0x1367 0x1368 0x1369 0x136A 0x136B 0x136C0x136D 0x136E 0x136F 0x1370 0x1371 0x1372 0x1373 0x13740x1375 0x1376 0x1377 0x1378 0x1379 0x137A 0x137B 0x137C0x137D 0x137E 0x137F 0x1380 0x1381 0x1382 0x1383 0x1384- Word Word Word Word Word BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word DWord BCD BCD BCD BCD BCD BCD Float 48 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 Demand_max_TP_Year Demand_max_TP_Month Demand_max_TP_Date Demand_max_TP_Hour Demand_max_TP_Min Demand_max_TP_Secon d 34998 34999 35000 35001 35002 35003 0x1385 0x1386 0x1387 0x1388 0x1389 0x138A Word Word Word Word Word BCD BCD BCD BCD BCD 2000-2099 1-12 1-31 0-23 0-59 35004 0x138B Word BCD 0-59 Modbus Module #19 Input Register : Diagnostic Last Reset Max/Min* Modbus Register Parameter name LR_Year LR_Month LR_Date LR_Hour LR_Min LR_Second Va_max_LR Va_max_LR_Year Va_max_LR_Month Va_max_LR_Date Va_max_LR_Hour Va_max_LR_Min Va_max_LR_Second Va_min_LR Va_min_LR_Year Va_min_LR_Month Va_min_LR_Date Va_min_LR_Hour Va_min_LR_Min Va_min_LR_Second Vb_max_LR Vb_max_LR_Year Vb_max_LR_Month Vb_max_LR_Date Vb_max_LR_Hour Vb_max_LR_Min Vb_max_LR_Second Vb_min_LR Vb_min_LR_Year Vb_min_LR_Month Vb_min_LR_Date Vb_min_LR_Hour Vb_min_LR_Min Vb_min_LR_Second Vc_max_LR Vc_max_LR_Year Vc_max_LR_Month Vc_max_LR_Date Vc_max_LR_Hour Vc_max_LR_Min Vc_max_LR_Second Vc_min_LR Vc_min_LR_Year Vc_min_LR_Month Vc_min_LR_Date Vc_min_LR_Hour Vc_min_LR_Min Vc_min_LR_Second Modicom Format 35005 35006 35007 35008 3509 35010 3501135012 35013 35014 35015 35016 35017 35018 3501935020 35021 35022 35023 35024 35025 35026 3502735028 35029 35030 35031 35032 35033 35034 3503535036 35037 35038 35039 35040 35041 35042 3504335044 35045 35046 35047 35048 35049 35050 3505135052 35053 35054 35055 35056 35057 35058 Len Data Type Range Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD 00-99 1-12 1-31 0-23 0-59 0-59 DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD Hex 0x138C 0x138D 0x138E 0x138F 0x1390 0x1391 0x13920x1393 0x1394 0x1395 0x1396 0x1397 0x1398 0x1399 0x139A0x139B 0x139C 0x139D 0x139E 0x139F 0x13A0 0x13A1 0x13A20x13A3 0x13A4 0x13A5 0x13A6 0x13A7 0x13A8 0x13A9 0x13AA0x13AB 0x13AC 0x13AD 0x13AE 0x13AF 0x13B0 0x13B1 0x13B20x13B3 0x13B4 0x13B5 0x13B6 0x13B7 0x13B8 0x13B9 0x13BA0x13BB 0x13BC 0x13BD 0x13BE 0x13BF 0x13C0 0x13C1 49 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 Default value Units Comment Ia_max_LR Ia_max_LR_Year Ia_max_LR_Month Ia_max_LR_Date Ia_max_LR_Hour Ia_max_LR_Min Ia_max_LR_Second Ia_min_LR Ia_min_LR_Year Ia_min_LR_Month Ia_min_LR_Date Ia_min_LR_Hour Ia_min_LR_Min Ia_min_LR_Second Ib_max_LR Ib_max_LR_Year Ib_max_LR_Month Ib_max_LR_Date Ib_max_LR_Hour Ib_max_LR_Min Ib_max_LR_Second Ib_min_LR Ib_min_LR_Year Ib_min_LR_Month Ib_min_LR_Date Ib_min_LR_Hour Ib_min_LR_Min Ib_min_LR_Second Ic_max_LR Ic_max_LR_Year Ic_max_LR_Month Ic_max_LR_Date Ic_max_LR_Hour Ic_max_LR_Min Ic_max_LR_Second Ic_min_LR Ic_min_LR_Year Ic_min_LR_Month Ic_min_LR_Date Ic_min_LR_Hour Ic_min_LR_Min Ic_min_LR_Second KWa_max_LR KWa_max_LR_Year KWa_max_LR_Month KWa_max_LR_Date KWa_max_LR_Hour KWa_max_LR_Min KWa_max_LR_Second KWa_min_LR KWa_min_LR_Date KWa_min_LR_Month KWa_min_LR_Date KWa_min_LR_Hour KWa_min_LR_Min KWa_min_LR_Second KWb_max_LR KWb_max_LR_Year KWb_max_LR_Month KWb_max_LR_Date KWb_max_LR_Hour 3505935060 35061 35062 35063 35064 35065 35066 3506735068 35069 35070 35071 35072 35073 35074 3507535076 35077 35078 35079 35080 35081 35082 3508335084 35085 35086 35087 35088 35089 35090 3509135092 35093 35094 35095 35096 35097 35098 3509935100 35101 35102 35103 35104 35105 35106 3510735108 35109 35110 35111 35112 35113 35114 3511535116 35117 35118 35119 35120 35121 35122 3512335124 35125 35126 35127 35128 0x13C20x13C3 0x13C4 0x13C5 0x13C6 0x13C7 0x13C8 0x13C9 0x13CA0x13CB 0x13CC 0x13CD 0x13CE 0x13CF 0x13D0 0x13D1 0x13D20x13D3 0x13D4 0x13D5 0x13D6 0x13D7 0x13D8 0x13D9 0x13DA0x13DB 0x13DC 0x13DD 0x13DE 0x13DF 0x13E0 0x13E1 0x13E20x13E3 0x13E4 0x13E5 0x13E6 0x13E7 0x13E8 0x13E9 0x13EA0x13EB 0x13EC 0x13ED 0x13EE 0x13EF 0x13F0 0x13F1 0x13F20x13F3 0x13F4 0x13F5 0x13F6 0x13F7 0x13F8 0x13F9 0x13FA0x13FB 0x13FC 0x13FD 0x13FE 0x13FF 0x1400 0x1401 0x14020x1403 0x1404 0x1405 0x1406 0x1407 DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word BCD BCD BCD BCD 50 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 KWb_max_LR_Min KWb_max_LR_Second KWb_min_LR KWb_min_LR_Year KWb_min_LR_Month KWb_min_LR_Date KWb_min_LR_Hour KWb_min_LR_Min KWb_min_LR_Second KWc_max_LR KWc_max_LR_Year KWc_max_LR_Month KWc_max_LR_Date KWc_max_LR_Hour KWc_max_LR_Min KWc_max_LR_Second KWc_min_LR KWc_min_LR_Year KWc_min_LR_Month KWc_min_LR_Date KWc_min_LR_Hour KWc_min_LR_Min KWc_min_LR_Second KVAa_max_LR KVAa_max_LR_Year KVAa_max_LR_Month KVAa_max_LR_Date KVAa_max_LR_Hour KVAa_max_LR_Min KVAa_max_LR_Second KVAa_min_LR KVAa_min_LR_Year KVAa_min_LR_Month KVAa_min_LR_Date KVAa_min_LR_Hour KVAa_min_LR_Min KVAa_min_LR_Second KVAb_max_LR KVAb_max_LR_Year KVAb_max_LR_Month KVAb_max_LR_Date KVAb_max_LR_Hour KVAb_max_LR_Min KVAb_max_LR_Second KVAb_min_LR KVAb_min_LR_Year KVAb_min_LR_Month KVAb_min_LR_Date KVAb_min_LR_Hour KVAb_min_LR_Min KVAb_min_LR_Second KVAc_max_LR KVAc_max_LR_Year KVAc_max_LR_Month KVAc_max_LR_Date KVAc_max_LR_Hour KVAc_max_LR_Min KVAc_max_LR_Second KVAc_min_LR KVAc_min_LR_Year KVAc_min_LR_Month 35129 35130 3513135132 35133 35134 35135 35136 35137 35138 3513935140 35141 35142 35143 35144 35145 35146 3514735148 35149 35150 35151 35152 35153 35154 3515535156 35157 35158 35159 35160 35161 35162 3516335164 35165 35166 35167 35168 35169 35170 3517135172 35173 35174 35175 35176 35177 35178 3517935180 35181 35182 35183 35184 35185 35186 3518735188 35189 35190 35191 35192 35193 35194 3519535196 35197 35198 0x1408 0x1409 0x140A0x140B 0x140C 0x140D 0x140E 0x140F 0x1410 0x1411 0x14120x1413 0x1414 0x1415 0x1416 0x1417 0x1418 0x1419 0x141A0x141B 0x141C 0x141D 0x141E 0x141F 0x1420 0x1421 0x14220x1423 0x1424 0x1425 0x1426 0x1427 0x1428 0x1429 0x142A0x142B 0x142C 0x142D 0x142E 0x142F 0x1430 0x1431 0x14320x1433 0x1434 0x1435 0x1436 0x1437 0x1438 0x1439 0x143A0x143B 0x143C 0x143D 0x143E 0x143F 0x1440 0x1441 0x14420x1443 0x1444 0x1445 0x1446 0x1447 0x1448 0x1449 0x144A0x144B 0x144C 0x144D Word Word BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word BCD BCD 51 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 KVAc_min_LR_Date KVAc_min_LR_Hour KVAc_min_LR_Min KVAc_min_LR_Second PFa_min_LR PFa_min_LR_Year PFa_min_LR_Month PFa_min_LR_Date PFa_min_LR_Hour PFa_min_LR_Min PFa_min_LR_Second PFb_min_LR PFb_min_LR_Year PFb_min_LR_Month PFb_min_LR_Date PFb_min_LR_Hour PFb_min_LR_Min PFb_min_LR_Second PFc_min_LR PFc_min_LR_Year PFc_min_LR_Month PFc_min_LR_Date PFc_min_LR_Hour PFc_min_LR_Min PFc_min_LR_Second VaTHD_max_LR VaTHD_max_LR_Year VaTHD_max_LR_Month VaTHD_max_LR_Date VaTHD_max_LR_Hour VaTHD_max_LR_Min VaTHD_max_LR_Second VbTHD_max_LR VbTHD_max_LR_Year VbTHD_max_LR_Month VbTHD_max_LR_Date VbTHD_max_LR_Hour VbTHD_max_LR_Min VbTHD_max_LR_Second VcTHD_max_LR VcTHD_max_LR_Year VcTHD_max_LR_Month VcTHD_max_LR_Date VcTHD_max_LR_Hour VcTHD_max_LR_Min VcTHD_max_LR_Second IaTHD_max_LR IaTHD_max_LR_Year IaTHD_max_LR_Month IaTHD_max_LR_Date IaTHD_max_LR_Hour IaTHD_max_LR_Min IaTHD_max_LR_Second IbTHD_max_LR IbTHD_max_LR_Year IbTHD_max_LR_Month IbTHD_max_LR_Date IbTHD_max_LR_Hour IbTHD_max_LR_Min IbTHD_max_LR_Second IcTHD_max_LR 35199 35200 35201 35202 3520335204 35205 35206 35207 35208 35209 35210 3521135212 35213 35214 35215 35216 35217 35218 3521935220 35221 35222 35223 35224 35225 35226 3522735228 35229 35230 35231 35232 35233 35234 3523535236 35237 35238 35239 35240 35241 35242 3524335244 35245 35246 35247 35248 35249 35250 3525135252 35253 35254 35255 35256 35257 35258 3525935260 35261 35262 35263 35264 35265 35266 3526735268 0x144E 0x144F 0x1450 0x1451 0x14520x1453 0x1454 0x1455 0x1456 0x1457 0x1458 0x1459 0x145A0x145B 0x145C 0x145D 0x145E 0x145F 0x1460 0x1461 0x14620x1463 0x1464 0x1465 0x1466 0x1467 0x1468 0x1469 0x146A0x146B 0x146C 0x146D 0x146E 0x146F 0x1470 0x1471 0x14720x1473 0x1474 0x1475 0x1476 0x1477 0x1478 0x1479 0x147A0x147B 0x147C 0x147D 0x147E 0x147F 0x1480 0x1481 0x14820x1483 0x1484 0x1485 0x1486 0x1487 0x1488 0x1489 0x148A0x148B 0x148C 0x148D 0x148E 0x148F 0x1490 0x1491 0x14920x1493 Word Word Word Word BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD DWord Float 52 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 00-99 1-12 1-31 0-23 0-59 0-59 IcTHD_max_LR_Year IcTHD_max_LR_Month IcTHD_max_LR_Date IcTHD_max_LR_Hour IcTHD_max_LR_Min IcTHD_max_LR_Second Demand_max_LR Demand_max_LR_Year Demand_max_LR_Month Demand_max_LR_Date Demand_max_LR_Hour Demand_max_LR_Min Demand_max_LR_Secon d KWH_del_LR KWH_rec_LR KWH_tot_LR 35269 35270 35271 35272 35273 35274 3527535276 35277 35278 35279 35280 35281 0x1494 0x1495 0x1496 0x1497 0x1498 0x1499 0x149A0x149B 0x149C 0x149D 0x149E 0x149F 0x14A0 35282 0x14A1 3528335284 3528535286 3528735288 0x14A20x14A3 0x14A40x14A5 0x14A60x14A7 Word Word Word Word Word Word BCD BCD BCD BCD BCD BCD 00-99 1-12 1-31 0-23 0-59 0-59 DWord Float Word Word Word Word Word BCD BCD BCD BCD BCD 2000-2099 1-12 1-31 0-23 0-59 Word BCD 0-59 DWord Float DWord Float DWord Float Modbus Module #20 Input Register : Event Log Sag Record* Modbus Register Len Data Type 0x14A8 Word UINT 35290 0x14A9 Word INT Sag01_Phase 35291 0x14AA Word UINT Sag01_Start_Time 3529235297 0x14AB0x14B0 Word x 6 Date & Time (BCD) Parameter name Sag01_Duration_Cycles Modicom Format 35289 Sag01_Data Hex Sag01_End_Time 3529835303 0x14B10x14B6 Word x 6 Date & Time (BCD) Sag02_Duration_Cycles 35304 0x14B7 Word UINT Sag02_Data 35305 0x14B8 Word INT Sag02_Phase 35306 0x14B9 Word UINT Sag02_Start_time 3530735312 0x14BA0x14BF Word x 6 Date & Time (BCD) Word x 6 Date & Time (BCD) Sag02_End_time 3531335318 0x14C00x14C5 Sag03_Duration_Cycles 35319 0x14C6 Word UINT Sag03_Data 35320 0x14C7 Word INT Sag03_Phase 35321 0x14C8 Word UINT 53 Range Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Default value Units Comment Sag03_Start_time 3532235327 0x14C90x14CE Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Sag03_End_time 3532835333 0x14CF0x14D4 Word x 6 Date & Time (BCD) Sag04_Duration_Cycles 35334 0x14D5 Word UINT Sag04_Data 35335 0x14D6 Word INT Sag04_Phase 35336 0x14D7 Word UINT Sag04_Start_time 3533735342 0x14D80x14DD Word x 6 Date & Time (BCD) Sag04_End_time 3534335348 0x14DE0x14E3 Word x 6 Date & Time (BCD) Sag05_Duration_Cycles 35349 0x14E4 Word UINT Sag05_Data 35350 0x14E5 Word INT Sag05_Phase 35351 0x14E6 Word UINT Sag05_Start_time 3535235357 0x14E70x14EC Word x 6 Date & Time (BCD) Word x 6 Date & Time (BCD) Sag05_End_time 3535835363 0x14ED0x14F2 Sag06_Duration_Cycles 35364 0x14F3 Word UINT Sag06_Data 35365 0x14F4 Word INT Sag06_Phase 35366 0x14F5 Word UINT Sag06_Start_time 3536735372 0x14F60x14FB Word x 6 Date & Time (BCD) Sag06_End_time 3537335378 0x14FC0x1501 Word x 6 Date & Time (BCD) Sag07_Duration_Cycles 35379 0x1502 Word UINT Sag07_Data 35380 0x1503 Word INT Sag07_Phase 35381 0x1504 Word UINT 54 Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Sag07_Start_time 3538235387 0x15050x150A Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Sag07_End_time 3538835393 0x150B0x1510 Word x 6 Date & Time (BCD) Sag08_Duration_Cycles 35394 0x1511 Word UINT Sag08_Data 35385 0x1512 Word INT Sag08_Phase 35396 0x1513 Word UINT Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Sag08_Start_time Sag08_End_time 3539735402 3540335408 0x15140x1519 0x151A0x151F Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Sag09_Duration_Cycles 35409 0x1520 Word UINT Sag09_Data 35410 0x1521 Word INT Sag09_Phase 35411 0x1522 Word UINT Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Sag09_Start_time 3541235417 0x15230x1528 Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Sag09_End_time 3541835423 0x15290x152E Word x 6 Date & Time (BCD) Sag10_Duration_Cycles 35424 0x152F Word UINT Sag10_Data 35425 0x1530 Word INT Sag10_Phase 35426 0x1531 Word UINT Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Sag10_Start_time 3542735432 0x15320x1537 Sag10_End_time 3543335438 0x15380x153D Word x 6 Date & Time (BCD) Sag11_Duration_Cycles 35439 0x153E Word UINT Sag11_Data 35440 0x153F Word INT Sag11_Phase 35441 0x1540 Word UINT 55 Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Sag11_Start_time 3544235447 0x15410x1546 Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Sag11_End_time 3544835453 0x15470x154C Word x 6 Date & Time (BCD) Sag12_Duration_Cycles 35454 0x154D Word UINT Sag12_Data 35455 0x154E Word INT Sag12_Phase 35456 0x154F Word UINT Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Sag12_Start_time Sag12_End_time 3545735462 3546335468 0x15500x1555 0x15560x155B Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Sag13_Duration_Cycles 35469 0x155C Word UINT Sag13_Data 35470 0x155D Word INT Sag13_Phase 35471 0x155E Word UINT Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Sag13_Start_time 3547235477 0x155F0x1564 Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Sag13_End_time 3547835483 0x15650x156A Word x 6 Date & Time (BCD) Sag14_Duration_Cycles 35484 0x156B Word UINT Sag14_Data 35485 0x156C Word INT Sag14_Phase 35486 0x156D Word UINT Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Sag14_Start_time 3548735492 0x156E0x1573 Sag14_End_time 3549335498 0x15740x1579 Word x 6 Date & Time (BCD) Sag15_Duration_Cycles 35499 0x157A Word UINT 56 Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Sag15_Data 35500 0x157B Word INT Sag15_Phase 35501 0x157C Word UINT Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Sag15_Start_time 3550235507 0x157D0x1582 Sag15_End_time 3550835513 0x15830x1588 Word x 6 Date & Time (BCD) Sag16_Duration_Cycles 35514 0x1589 Word UINT Sag16_Data 35515 0x158A Word INT Sag16_Phase 35516 0x158B Word UINT Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Sag16_Start_time Sag16_End_time 3551735522 3552335528 0x158C0x1591 0x15920x1597 Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Sag17_Duration_Cycles 35529 0x1598 Word UINT Sag17_Data 35530 0x1599 Word INT Sag17_Phase 35531 0x159A Word UINT Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Sag17_Start_time Sag17_End_time 3553235537 3553835543 0x159B0x15A0 0x15A10x15A6 Sag18_Duration_Cycles 35544 0x15A7 Word UINT Sag18_Data 35545 0x15A8 Word INT Sag18_Phase 35546 0x15A9 Word UINT Word x 6 Date & Time (BCD) Sag18_Start_time 3554735552 0x15AA0x15AF 57 Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Sag18_End_time 3555335558 0x15B00x15B5 Word x 6 Date & Time (BCD) Sag19_Duration_Cycles 35559 0x15B6 Word UINT Sag19_Data 35560 0x15B7 Word INT Sag19_Phase 35561 0x15B8 Word UINT Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Sag19_Start_time Sag19_End_time 3556235567 3556835573 0x15B90x15BE 0x15BF0x15C4 Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Sag20_Duration_Cycles 35574 0x15C5 Word UINT Sag20_Data 35575 0x15C6 Word INT Sag20_Phase 35576 0x15C7 Word UINT Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Sag20_Start_time Sag20_End_time 3557735582 3558335588 0x15C80x15CD 0x15CE0x15D3 Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Modbus Module #21 Input Register : Event Log Swell Record* Modbus Register Parameter name Len Data Type 0x15D4 Word UINT 35590 0x15D5 Word INT 35591 0x15D6 Word UINT Word x 6 Date & Time (BCD) Swell01_Duration_Cycles Modicom Format 35589 Swell01_Data Swell01_Phase Swell01_Start_Time 3559235597 Hex 0x15D70x15DC 58 Range Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Default value Units Comment Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Swell01_End_Time 3559835603 0x15DD0x15E2 Word x 6 Date & Time (BCD) Swell02_Duration_Cycles 35604 0x15E3 Word UINT Swell02_Data 35605 0x15E4 Word INT Swell02_Phase 35606 0x15E5 Word UINT Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Swell02_Start_time 3560735612 0x15E60x15EB Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Swell02_End_time 3561335618 0x15EC0x15F1 Word x 6 Date & Time (BCD) Swell03_Duration_Cycles 35619 0x15F2 Word UINT Swell03_Data 35620 0x15F3 Word INT Swell03_Phase 35621 0x15F4 Word UINT Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Swell03_Start_time 3562235627 0x15F50x15FA Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Swell03_End_time 3562835633 0x15FB0x1600 Word x 6 Date & Time (BCD) Swell04_Duration_Cycles 35634 0x1601 Word UINT Swell04_Data 35635 0x1602 Word INT Swell04_Phase 35636 0x1603 Word UINT Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Swell04_Start_time 3563735642 0x16040x1609 Swell04_End_time 3564335648 0x160A0x160F Word x 6 Date & Time (BCD) Swell05_Duration_Cycles 35649 0x1610 Word UINT Swell05_Data 35650 0x1611 Word INT Swell05_Phase 35651 0x1612 Word UINT 59 Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Swell05_Start_time Swell05_End_time 3565235657 3565835663 0x16130x1618 0x16190x161E Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Swell06_Duration_Cycles 35664 0x161F Word UINT Swell06_Data 35665 0x1620 Word INT Swell06_Phase 35666 0x1621 Word UINT Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Swell06_Start_time 3566735672 0x16220x1627 Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Swell06_End_time 3567335678 0x16280x162D Word x 6 Date & Time (BCD) Swell07_Duration_Cycles 35679 0x162E Word UINT Swell07_Data 35680 0x162F Word INT Swell07_Phase 35681 0x1630 Word UINT Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Swell07_Start_time 3568235687 0x16310x1636 Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Swell07_End_time 3568835693 0x16370x163C Word x 6 Date & Time (BCD) Swell08_Duration_Cycles 35694 0x163D Word UINT Swell08_Data 35695 0x163E Word INT Swell08_Phase 35696 0x163F Word UINT Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Swell08_Start_time 3569735702 0x16400x1645 Swell08_End_time 3570335708 0x16460x164B Word x 6 Date & Time (BCD) Swell09_Duration_Cycles 35709 0x164C Word UINT 60 Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Swell09_Data 35710 0x164D Word INT Swell09_Phase 35711 0x164E Word UINT Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Swell09_Start_time 3571235717 0x164F0x1654 Swell09_End_time 3571835723 0x16550x165A Word x 6 Date & Time (BCD) Swell10_Duration_Cycles 35724 0x165B Word UINT Swell10_Data 35725 0x165C Word INT Swell10_Phase 35726 0x165D Word UINT Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Swell10_Start_time 3572735732 0x165E0x1663 Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Swell10_End_time 3573335738 0x16640x1669 Word x 6 Date & Time (BCD) Swell11_Duration_Cycles 35739 0x166A Word UINT Swell11_Data 35740 0x166B Word INT Swell11_Phase 35741 0x166C Word UINT Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Swell11_Start_time 3574235747 0x166D0x1672 Swell11_End_time 3574835753 0x16730x1678 Word x 6 Date & Time (BCD) Swell12_Duration_Cycles 35754 0x1679 Word UINT Swell12_Data 35755 0x167A Word INT Swell12_Phase 35756 0x167B Word UINT Word x 6 Date & Time (BCD) Swell12_Start_time 3575735762 0x167C0x1681 61 Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Swell12_End_time 3576335768 0x16820x1687 Word x 6 Date & Time (BCD) Swell13_Duration_Cycles 35769 0x1688 Word UINT Swell13_Data 35770 0x1689 Word INT Swell13_Phase 35771 0x168A Word UINT Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Swell13_Start_time 3577235777 0x168B0x1690 Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Swell13_End_time 3577835783 0x16910x1696 Word x 6 Date & Time (BCD) Swell14_Duration_Cycles 35784 0x1697 Word UINT Swell14_Data 35785 0x1698 Word INT Swell14_Phase 35786 0x1699 Word UINT Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Swell14_Start_time 3578735792 0x169A0x169F Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Swell14_End_time 3579335798 0x16A00x16A5 Word x 6 Date & Time (BCD) Swell15_Duration_Cycles 35799 0x16A6 Word UINT Swell15_Data 35800 0x16A7 Word INT Swell15_Phase 35801 0x16A8 Word UINT Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Swell15_Start_time 3580235807 0x16A90x16AE Swell15_End_time 3580835813 0x16AF0x16B4 Word x 6 Date & Time (BCD) Swell16_Duration_Cycles 35814 0x16B5 Word UINT Swell16_Data 35815 0x16B6 Word INT Swell16_Phase 35816 0x16B7 Word UINT 62 Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Swell16_Start_time 3581735822 0x16B80x16BD Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Swell16_End_time 3582335828 0x16BE0x16C3 Word x 6 Date & Time (BCD) Swell17_Duration_Cycles 35829 0x16C4 Word UINT Swell17_Data 35830 0x16C5 Word INT Swell17_Phase 35831 0x16C6 Word UINT Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Swell17_Start_time 3583235837 0x16C70x16CC Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Swell17_End_time 3583835843 0x16CD0x16D2 Word x 6 Date & Time (BCD) Swell18_Duration_Cycles 35844 0x16D3 Word UINT Swell18_Data 35845 0x16D4 Word INT Swell18_Phase 35846 0x16D5 Word UINT Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Swell18_Start_time Swell18_End_time 3584735852 3585335858 0x16D60x16DB 0x16DC0x16E1 Swell19_Duration_Cycles 35859 0x16E2 Word UINT Swell19_Data 35860 0x16E3 Word INT Swell19_Phase 35861 0x16E4 Word UINT Word x 6 Date & Time (BCD) Swell19_Start_time 3586235867 0x16E50x16EA 63 Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Swell19_End_time 3586835873 0x16EB0x16F0 Word x 6 Date & Time (BCD) Swell20_Duration_Cycles 35874 0x16F1 Word UINT Swell20_Data 35875 0x16F2 Word INT Swell20_Phase 35876 0x16F3 Word UINT Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Word x 6 Date & Time (BCD) Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Swell20_Start_time Swell20_End_time 3587735882 3588335888 0x16F40x16F9 0x16FA0x16FF Range : -327.68% ~ 327.67% 0: A phase 1: B phase 2: C phase Modbus Module #22 Input Register : Event Log Alarm Record* Modbus Register Parameter name Alarm01_Item Modicom Format 35889 Alarm01_Data 35890 Alarm01_Time 3589135896 Len Data Type 0x1700 Word UINT 0x1701 Word INT Word x 6 Date & Time (BCD) Hex 0x17020x1707 Alarm02_Item 35897 0x1708 Word UINT Alarm02_Data 35898 0x1709 Word INT Alarm02_Time 3589935904 0x170A0x170F Word x 6 Date & Time (BCD) Alarm03_Item 35905 0x1710 Word UINT Alarm03_Data 35906 0x1711 Word INT Alarm03_Time 3590735912 0x17120x1717 Word x 6 Date & Time (BCD) Alarm04_Item 35913 0x1718 Word UINT Alarm04_Data 35914 0x1719 Word INT 64 Range Range : -327.68% ~ 327.67% Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Range : -327.68% ~ 327.67% Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Range : -327.68% ~ 327.67% Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Range : -327.68% ~ 327.67% Default value Units Comment Alarm04_Time 3591535920 0x171A0x171F Word x 6 Date & Time (BCD) Alarm05_Item 35921 0x1720 Word UINT Alarm05_Data 35922 0x1721 Word INT Alarm05_Time 3592335928 0x17220x1727 Word x 6 Date & Time (BCD) Alarm06_Item 35929 0x1728 Word UINT Alarm06_Data 35930 0x1729 Word INT Alarm06_Time 3593135936 0x172A0x172F Word x 6 Date & Time (BCD) Alarm07_Item 35937 0x1730 Word UINT Alarm07_Data 35938 0x1731 Word INT Word x 6 Date & Time (BCD) Alarm07_Time 3593935944 0x17320x1737 Alarm08_Item 35945 0x1738 Word UINT Alarm08_Data 35946 0x1739 Word INT Word x 6 Date & Time (BCD) Alarm08_Time 3594735952 0x173A0x173F Alarm09_Item 35953 0x1740 Word UINT Alarm09_Data 35954 0x1741 Word INT Alarm09_Time 3595535960 0x17420x1747 Word x 6 Date & Time (BCD) Alarm10_Item 35961 0x1748 Word UINT Alarm10_Data 35962 0x1749 Word INT Alarm10_Time 3596335968 0x174A0x174F Word x 6 Date & Time (BCD) Alarm11_Item 35969 0x1750 Word UINT Alarm11_Data 35970 0x1751 Word INT 65 Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Range : -327.68% ~ 327.67% Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Range : -327.68% ~ 327.67% Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Range : -327.68% ~ 327.67% Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Range : -327.68% ~ 327.67% Year : 2000-2099 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Range : -327.68% ~ 327.67% Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Range : -327.68% ~ 327.67% Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Range : -327.68% ~ 327.67% Alarm11_Time 3597135976 0x17520x1757 Word x 6 Date & Time (BCD) Alarm12_Item 35977 0x1758 Word UINT Alarm12_Data 35978 0x1759 Word INT Word x 6 Date & Time (BCD) Alarm12_Time 3597935984 0x175A0x175F Alarm13_Item 35985 0x1760 Word UINT Alarm13_Data 35986 0x1761 Word INT Alarm13_Time 3598735992 0x17620x1767 Word x 6 Date & Time (BCD) Alarm14_Item 35993 0x1768 Word UINT Alarm14_Data 35994 0x1769 Word INT Alarm14_Time 3599536000 0x176A0x176F Word x 6 Date & Time (BCD) Alarm15_Item 36001 0x1770 Word UINT Alarm15_Data 36002 0x1771 Word INT Alarm15_Time 3600336008 0x17720x1777 Word x 6 Date & Time (BCD) Alarm16_Item 36009 0x1778 Word UINT Alarm16_Data 36010 0x1779 Word INT Alarm16_Time 3601136016 0x177A0x177F Word x 6 Date & Time (BCD) Alarm17_Item 36017 0x1780 Word UINT Alarm17_Data 36018 0x1781 Word INT Alarm17_Time 3601936024 0x17820x1787 Word x 6 Date & Time (BCD) Alarm18_Item 36025 0x1788 Word UINT Alarm18_Data 36026 0x1789 Word INT Alarm18_Time 3602736032 0x178A0x178F Word x 6 Date & Time (BCD) 66 Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Range : -327.68% ~ 327.67% Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Range : -327.68% ~ 327.67% Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Range : -327.68% ~ 327.67% Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Range : -327.68% ~ 327.67% Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Range : -327.68% ~ 327.67% Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Range : -327.68% ~ 327.67% Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Range : -327.68% ~ 327.67% Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Alarm19_Item 36033 0x1790 Word UINT Alarm19_Data 36034 0x1791 Word INT Alarm19_Time 3603536040 0x17920x1797 Word x 6 Date & Time (BCD) Alarm20_Item 36041 0x1798 Word UINT Alarm20_Data 36042 0x1799 Word INT Alarm20_Time 3604336048 0x179A0x179F Word x 6 Date & Time (BCD) Range : -327.68% ~ 327.67% Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Range : -327.68% ~ 327.67% Year : 00-99 Month : 1-12 Date : 1-31 Hour : 0-23 Minute : 0-59 Second : 0-59 Modbus Module #23 Input Register : Total Harmonics* Modbus Register Parameter name TOT_HD_V_a TOT_HD_V_b TOT_HD_V_c TOT_HD_I_a TOT_HD_I_b TOT_HD_I_c TOT_HD_I_n Modicom Format 3665736658 3665936660 3666136662 3666336664 3666536666 3666736668 3666936670 Len Data Type DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float Hex 0x1A000x1A01 0x1A020x1A03 0x1A040x1A05 0x1A060x1A07 0x1A080x1A09 0x1A0A0x1A0B 0x1A0C0x1A0D Range Default value Units Comment Units Comment Modbus Module #24 Input Register : Total Odd & Even Harmonics* Modbus Register Parameter name TOT_EVEN_HD_V_a TOT_EVEN_HD_V_b TOT_EVEN_HD_V_c TOT_EVEN_HD_I_a TOT_EVEN_HD_I_b TOT_EVEN_HD_I_c TOT_EVEN_HD_I_n TOT_ODD_HD_V_a TOT_ODD_HD_V_b TOT_ODD_HD_V_c TOT_ODD_HD_I_a Modicom Format 3667136672 3667336674 3667536676 3667736678 3667936680 3668136682 3668336684 3668536686 3668736688 3668936690 3669136692 Len Data Type DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float Hex 0x1A0E0x1A0F 0x1A100x1A11 0x1A120x1A13 0x1A140x1A15 0x1A160x1A17 0x1A180x1A19 0x1A1A0x1A1B 0x1A1C0x1A1D 0x1A1E0x1A1F 0x1A200x1A21 0x1A220x1A23 67 Range Default value TOT_ODD_HD_I_b TOT_ODD_HD_I_c TOT_ODD_HD_I_n 3669336694 3669536696 3669736698 0x1A240x1A25 0x1A260x1A27 0x1A280x1A29 DWord Float DWord Float DWord Float Modbus Module #25 Input Register : Phase A Voltage Harmonics* Modbus Register Parameter name Reserved HD1_V_a HD2_V_a HD3_V_a HD4_V_a HD5_V_a HD6_V_a HD7_V_a HD8_V_a HD9_V_a HD10_V_a HD11_V_a HD12_V_a HD13_V_a HD14_V_a HD15_V_a HD16_V_a HD17_V_a HD18_V_a HD19_V_a HD20_V_a HD21_V_a HD22_V_a HD23_V_a HD24_V_a HD25_V_a HD26_V_a HD27_V_a HD28_V_a Modicom Format 3669936700 3670136702 3670336704 3670536706 3670736708 3670936710 3671136712 3671336714 3671536716 3671736718 3671936720 3672136722 3672336724 3672536726 3672736728 3672936730 3673136732 3673336734 3673536736 3673736738 3673936740 3674136742 3674336744 3674536746 3674736748 3674936750 3675136752 3675336754 3675536756 Len Data Type DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float Hex 0x1A2A0x1A2B 0x1A2C0x1A2D 0x1A2E0x1A2F 0x1A300x1A31 0x1A320x1A33 0x1A340x1A35 0x1A360x1A37 0x1A380x1A39 0x1A3A0x1A3B 0x1A3C0x1A3D 0x1A3E0x1A3F 0x1A400x1A41 0x1A420x1A43 0x1A440x1A45 0x1A460x1A47 0x1A480x1A49 0x1A4A0x1A4B 0x1A4C0x1A4D 0x1A4E0x1A4F 0x1A500x1A51 0x1A520x1A53 0x1A540x1A55 0x1A560x1A57 0x1A580x1A59 0x1A5A0x1A5B 0x1A5C0x1A5D 0x1A5E0x1A5F 0x1A600x1A61 0x1A620x1A63 68 Range Default value Units Comment HD29_V_a HD30_V_a HD31_V_a 3675736758 3675936760 3676136762 0x1A640x1A65 0x1A660x1A67 0x1A680x1A69 DWord Float DWord Float DWord Float Modbus Module #26 Input Register : Phase B Voltage Harmonics* Modbus Register Parameter name Reserved HD1_V_b HD2_V_b HD3_V_b HD4_V_b HD5_V_b HD6_V_b HD7_V_b HD8_V_b HD9_V_b HD10_V_b HD11_V_b HD12_V_b HD13_V_b HD14_V_b HD15_V_b HD16_V_b HD17_V_b HD18_V_b HD19_V_b HD20_V_b HD21_V_b HD22_V_b HD23_V_b HD24_V_b HD25_V_b HD26_V_b HD27_V_b HD28_V_b Modicom Format 3676336764 3676536766 3676736768 3676936770 3677136772 3677336774 3677536776 3677736778 3677936780 3678136782 3678336784 3678536786 3678736788 3678936790 3679136792 3679336794 3679536796 3679736798 3679936800 3680136802 3680336804 3680536806 3680736808 3680936810 3681136812 3681336814 3681536816 3681736818 3681936820 Len Data Type DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float Hex 0x1A6A0x1A6B 0x1A6C0x1A6D 0x1A6E0x1A6F 0x1A700x1A71 0x1A720x1A73 0x1A740x1A75 0x1A760x1A77 0x1A780x1A79 0x1A7A0x1A7B 0x1A7C0x1A7D 0x1A7E0x1A7F 0x1A800x1A81 0x1A820x1A83 0x1A840x1A85 0x1A860x1A87 0x1A880x1A89 0x1A8A0x1A8B 0x1A8C0x1A8D 0x1A8E0x1A8F 0x1A900x1A91 0x1A920x1A93 0x1A940x1A95 0x1A960x1A97 0x1A980x1A99 0x1A9A0x1A9B 0x1A9C0x1A9D 0x1A9E0x1A9F 0x1AA00x1AA1 0x1AA20x1AA3 69 Range Default value Units Comment HD29_V_b HD30_V_b HD31_V_b 3682136822 3682336824 3682536826 0x1AA40x1AA5 0x1AA60x1AA7 0x1AA80x1AA9 DWord Float DWord Float DWord Float Modbus Module #27 Input Register : Phase C Voltage Harmonics* Modbus Register Parameter name Reserved HD1_V_c HD2_V_c HD3_V_c HD4_V_c HD5_V_c HD6_V_c HD7_V_c HD8_V_c HD9_V_c HD10_V_c HD11_V_c HD12_V_c HD13_V_c HD14_V_c HD15_V_c HD16_V_c HD17_V_c HD18_V_c HD19_V_c HD20_V_c HD21_V_c HD22_V_c HD23_V_c HD24_V_c HD25_V_c HD26_V_c HD27_V_c HD28_V_c Modicom Format 3682736828 3682936830 3683136832 3683336834 3683536836 3683736838 3683936840 3684136842 3684336844 3684536846 3684736848 3684936850 3685136852 368536854 3685536856 3685736858 3685936860 3686136862 3686336864 3686536866 3686736868 3686936870 3687136872 3687336874 3687536876 3687736878 3687936880 3688136882 3688336884 Len Data Type DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float Hex 0x1AAA0x1AAB 0x1AAC0x1AAD 0x1AAE0x1AAF 0x1AB00x1AB1 0x1AB20x1AB3 0x1AB40x1AB5 0x1AB60x1AB7 0x1AB80x1AB9 0x1ABA0x1ABB 0x1ABC0x1ABD 0x1ABE0x1ABF 0x1AC00x1AC1 0x1AC20x1AC3 0x1AC40x1AC5 0x1AC60x1AC7 0x1AC80x1AC9 0x1ACA0x1ACB 0x1ACC0x1ACD 0x1ACE0x1ACF 0x1AD00x1AD1 0x1AD20x1AD3 0x1AD40x1AD5 0x1AD60x1AD7 0x1AD80x1AD9 0x1ADA0x1ADB 0x1ADC0x1ADD 0x1ADE0x1ADF 0x1AE00x1AE1 0x1AE20x1AE3 70 Range Default value Units Comment HD29_V_c HD30_V_c HD31_V_c 3688536886 3688736888 3688936890 0x1AE40x1AE5 0x1AE60x1AE7 0x1AE80x1AE9 DWord Float DWord Float DWord Float Modbus Module #28 Input Register : Phase A Current Harmonics* Modbus Register Parameter name Reserved HD1_I_a HD2_I_a HD3_I_a HD4_I_a HD5_I_a HD6_I_a HD7_I_a HD8_I_a HD9_I_a HD10_I_a HD11_I_a HD12_I_a HD13_I_a HD14_I_a HD15_I_a HD16_I_a HD17_I_a HD18_I_a HD19_I_a HD20_I_a HD21_I_a HD22_I_a HD23_I_a HD24_I_a HD25_I_a HD26_I_a HD27_I_a HD28_I_a Modicom Format 3689136892 3689336894 3689536896 3689736898 3689936900 3690136902 3690336904 3690536906 3690736908 3690936910 3691136912 3691336914 3691536916 3691736918 3691936920 3692136922 3692336924 3692536926 3692736928 3692936930 3693136932 3693336934 3693536936 3693736938 3693936940 3694136942 3694336944 3694536946 3694736948 Len Data Type DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float Hex 0x1AEA0x1AEB 0x1AEC0x1AED 0x1AEE0x1AEF 0x1AF00x1AF1 0x1AF20x1AF3 0x1AF40x1AF5 0x1AF60x1AF7 0x1AF80x1AF9 0x1AFA0x1AFB 0x1AFC0x1AFD 0x1AFE0x1AFF 0x1B000x1B01 0x1B020x1B03 0x1B040x1B05 0x1B060x1B07 0x1B080x1B09 0x1B0A0x1B0B 0x1B0C0x1B0D 0x1B0E0x1B0F 0x1B100x1B11 0x1B120x1B13 0x1B140x1B15 0x1B160x1B17 0x1B180x1B19 0x1B1A0x1B1B 0x1B1C0x1B1D 0x1B1E0x1B1F 0x1B200x1B21 0x1B220x1B23 71 Range Default value Units Comment HD29_I_a HD30_I_a HD31_I_a 3694936950 3695136952 3695336954 0x1B240x1B25 0x1B260x1B27 0x1B280x1B29 DWord Float DWord Float DWord Float Modbus Module #29 Input Register : Phase B Current Harmonics* Modbus Register Parameter name Reserved HD1_I_b HD2_I_b HD3_I_b HD4_I_b HD5_I_b HD6_I_b HD7_I_b HD8_I_b HD9_I_b HD10_I_b HD11_I_b HD12_I_b HD13_I_b HD14_I_b HD15_I_b HD16_I_b HD17_I_b HD18_I_b HD19_I_b HD20_I_b HD21_I_b HD22_I_b HD23_I_b HD24_I_b HD25_I_b HD26_I_b HD27_I_b HD28_I_b Modicom Format 3695536956 3695736958 3695936960 3696136962 3696336964 3696536966 3696736968 3696936970 3697136972 3697336974 3697536976 3697736978 3697936980 3698136982 3698336984 3698536986 3698736988 3698936990 3699136992 3699336994 3699536996 3699736998 3699937000 3700137002 3700337004 3700537006 3700737008 3700937010 3701137012 Len Data Type DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float Hex 0x1B2A0x1B2B 0x1B2C0x1B2D 0x1B2E0x1B2F 0x1B300x1B31 0x1B320x1B33 0x1B340x1B35 0x1B360x1B37 0x1B380x1B39 0x1B3A0x1B3B 0x1B3C0x1B3D 0x1B3E0x1B3F 0x1B400x1B41 0x1B420x1B43 0x1B440x1B45 0x1B460x1B47 0x1B480x1B49 0x1B4A0x1B4B 0x1B4C0x1B4D 0x1B4E0x1B4F 0x1B500x1B51 0x1B520x1B53 0x1B540x1B55 0x1B560x1B57 0x1B580x1B59 0x1B5A0x1B5B 0x1B5C0x1B5D 0x1B5E0x1B5F 0x1B600x1B61 0x1B620x1B63 72 Range Default value Units Comment HD29_I_b HD30_I_b HD31_I_b 3701337014 3701537016 3701737018 0x1B640x1B65 0x1B660x1B67 0x1B680x1B69 DWord Float DWord Float DWord Float Modbus Module #30 Input Register : Phase C Current Harmonics* Modbus Register Parameter name Reserved HD1_I_c HD2_I_c HD3_I_c HD4_I_c HD5_I_c HD6_I_c HD7_I_c HD8_I_c HD9_I_c HD10_I_c HD11_I_c HD12_I_c HD13_I_c HD14_I_c HD15_I_c HD16_I_c HD17_I_c HD18_I_c HD19_I_c HD20_I_c HD21_I_c HD22_I_c HD23_I_c HD24_I_c HD25_I_c HD26_I_c HD27_I_c HD28_I_c Modicom Format 3701937020 3702137022 3702337024 3702537026 3702737028 3702937030 3703137032 3703337034 3703537036 3703737038 3703937040 3704137042 3704337044 3704537046 3704737048 3704937050 3705137052 3705337054 3705537056 3705737058 3705937060 3706137062 3706337064 3706537066 3706737068 3707937070 3707137072 3707337074 3707537076 Len Data Type DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float Hex 0x1B6A0x1B6B 0x1B6C0x1B6D 0x1B6E0x1B6F 0x1B700x1B71 0x1B720x1B73 0x1B740x1B75 0x1B760x1B77 0x1B780x1B79 0x1B7A0x1B7B 0x1B7C0x1B7D 0x1B7E0x1B7F 0x1B800x1B81 0x1B820x1B83 0x1B840x1B85 0x1B860x1B87 0x1B880x1B89 0x1B8A0x1B8B 0x1B8C0x1B8D 0x1B8E0x1B8F 0x1B900x1B91 0x1B920x1B93 0x1B940x1B95 0x1B960x1B97 0x1B980x1B99 0x1B9A0x1B9B 0x1B9C0x1B9D 0x1B9E0x1B9F 0x1BA00x1BA1 0x1BA20x1BA3 73 Range Default value Units Comment HD29_I_c HD30_I_c HD31_I_c 3707737078 3707937080 3708137082 0x1BA40x1BA5 0x1BA60x1BA7 0x1BA80x1BA9 DWord Float DWord Float DWord Float Modbus Module #31 Input Register : Neutral Current Harmonics* Modbus Register Parameter name Reserved HD1_I_n HD2_I_n HD3_I_n HD4_I_n HD5_I_n HD6_I_n HD7_I_n HD8_I_n HD9_I_n HD10_I_n HD11_I_n HD12_I_n HD13_I_n HD14_I_n HD15_I_n HD16_I_n HD17_I_n HD18_I_n HD19_I_n HD20_I_n HD21_I_n HD22_I_n HD23_I_n HD24_I_n HD25_I_n HD26_I_n HD27_I_n HD28_I_n Modicom Format 3708337084 3708537086 3708737088 3708937090 3709137092 3709337094 3709537096 3709737098 3709937100 3710137102 37103 37104 3710537106 3710737108 3710937110 3711137112 3711337114 3711537116 3711737118 3711937120 3712137122 3712337124 3712537126 3712737128 3712937130 3713137132 3713337134 3713537136 3713737138 3713937140 Len Data Type DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float Hex 0x1BAA0x1BAB 0x1BAC0x1BAD 0x1BAE0x1BAF 0x1BB00x1BB1 0x1BB20x1BB3 0x1BB40x1BB5 0x1BB60x1BB7 0x1BB80x1BB9 0x1BBA0x1BBB 0x1BBC0x1BBD 0x1BBE0x1BBF 0x1BC00x1BC1 0x1BC20x1BC3 0x1BC40x1BC5 0x1BC60x1BC7 0x1BC80x1BC9 0x1BCA0x1BCB 0x1BCC0x1BCD 0x1BCE0x1BCF 0x1BD00x1BD1 0x1BD20x1BD3 0x1B40x1BD5 0x1BD60x1BD7 0x1BD80x1BD9 0x1BDA0x1BDB 0x1BDC0x1BDD 0x1BDE0x1BDF 0x1BE00x1BE1 0x1BE20x1BE3 74 Range Default value Units Comment HD29_I_n HD30_I_n HD31_I_n 3714137142 3714337144 3714537146 0x1BE40x1BE5 0x1BE60x1BE7 0x1BE80x1BE9 DWord Float DWord Float DWord Float Modbus Module #32 Input Register : Realtime Data Voltage, Current, Frequency (Unsigned Int) Modbus Register Parameter name Vln_a Vln_b Vln_c Vln_avg Vll_ab Vll_bc Vll_ca Vll_avg I_a I_b I_c I_avg I_n Freq Modicom Format 38449 38450 38451 38452 38453 38454 38455 38456 38457 38458 38459 38460 38461 38462 Len Data Type Range Word Word Word Word Word Word Word Word Word Word Word Word Word Word UINT UINT UINT UINT UINT UINT UINT UINT UINT UINT UINT UINT UINT UINT 0-65535 0-65535 0-65535 0-65535 0-65535 0-65535 0-65535 0-65535 0-65535 0-65535 0-65535 0-65535 0-65535 0-9999 Hex 0x2100 0x2101 0x2102 0x2103 0x2104 0x2105 0x2106 0x2107 0x2108 0x2109 0x210A 0x210B 0x210C 0x210D Default value Units 0.1V 0.1V 0.1V 0.1V 0.1V 0.1V 0.1V 0.1V mA. mA. mA. mA. mA. 0.01Hz Comment Secondary Secondary Secondary Secondary Secondary Secondary Secondary Secondary Secondary Secondary Secondary Secondary Secondary Modbus Module #33 Input Register : Realtime Data Power Result (Int) Modbus Register Parameter name KW_a KW_b KW_c KW_tot KVAR_a KVAR_b KVAR_c KVAR_tot KVA_a KVA_b KVA_c KVA_tot Modicom Format 38463 38464 38465 38466 38467 38468 38469 38470 38471 38472 38473 38474 Len Data Type Range Word Word Word Word Word Word Word Word Word Word Word Word INT INT INT INT INT INT INT INT INT INT INT INT -32768-32767 -32768-32767 -32768-32767 -32768-32767 -32768-32767 -32768-32767 -32768-32767 -32768-32767 0-32767 0-32767 0-32767 0-32767 Hex 0x210E 0x210F 0x2110 0x2111 0x2112 0x2113 0x2114 0x2115 0x2116 0x2117 0x2118 0x2119 Default value Units W W W W var var var var VA VA VA VA Comment Secondary Secondary Secondary Secondary Secondary Secondary Secondary Secondary Secondary Secondary Secondary Secondary Modbus Module #34 Input Register : Realtime Data Power Factor & Phase Angle (Int) Modbus Register Parameter name PF_signed_a PF_signed_b PF_signed_c PF_signed_avg PhaseAngle_V_a PhaseAngle_V_b PhaseAngle_V_c PhaseAngle_I_a PhaseAngle_I_b PhaseAngle_I_c Reserved Reserved Reserved Modicom Format 38475 38476 38477 38478 38479 38480 38481 38482 38483 38484 38485 38486 38487 Len Data Type Word Word Word Word Word Word Word Word Word Word Word Word Word INT INT INT INT INT INT INT INT INT INT INT INT INT Hex 0x211A 0x211B 0x211C 0x211D 0x211E 0x211F 0x2120 0x2121 0x2122 0x2123 0x2124 0x2125 0x2126 75 Range -1000~+1000 -1000~+1000 -1000~+1000 -1000~+1000 -1800~+1800 -1800~+1800 -1800~+1800 -1800~+1800 -1800~+1800 -1800~+1800 Default value Units 0.001 0.001 0.001 0.001 0.1 0.1 0.1 0.1 0.1 0.1 Comment Modbus Module #35 Input Register : Realtime Data Energy & Demand(Unsigned Int) Modbus Register Parameter name KWH_del KWH_rec KWH_tot KWH_net KVARH_del (+ lagging) KVARH_rec (- leading) KVARH_tot KVARH_net KVAH Demand_kW* Demand_Remain_Time* Pre_Demand_kW* Pre_Demand_kvar* Demand_kvar* Pre_Demand_kVA* Demand_kVA* Modicom Format 38488 38489 38490 38491 38492 38493 38494 38495 38496 38497 38498 38499 38500 38501 38502 38503 38504 38505 38506 38507 38508 38509 38510 38511 38512 38513 38514 38515 38516 38517 38518 38519 38520 38521 Len Data Type Range Word Word Word Word Word Word Word Word Word Word Word Word Word Word Word Word Word Word Word Word Word Word Word Word Word Word Word Word Word Word Word Word Word Word UINT UINT UINT UINT UINT UINT UINT UINT UINT UINT UINT UINT UINT UINT UINT UINT UINT UINT UINT UINT UINT UINT UINT UINT UINT UINT UINT INT UINT INT INT INT INT INT 0-999 0-999 0-999 0-999 0-999 0-999 0-999 0-999 0-999 0-999 0-999 0-999 0-999 0-999 0-999 0-999 0-999 0-999 0-999 0-999 0-999 0-999 0-999 0-999 0-999 0-999 0-999 -32768-32767 0-65535 -32768-32767 -32768-32767 -32768-32767 -32768-32767 -32768-32767 Hex 0x2127 0x2128 0x2129 0x212A 0x212B 0x212C 0x212D 0x212E 0x212F 0x2130 0x2131 0x2132 0x2133 0x2134 0x2135 0x2136 0x2137 0x2138 0x2139 0x213A 0x213B 0x213C 0x213D 0x213E 0x213F 0x2140 0x2141 0x2142 0x2143 0x2144 0x2145 0x2146 0x2147 0x2148 Default value Units 1000000 1000 0.1 1000000 1000 0.1 1000000 1000 0.1 1000000 1000 0.1 1000000 1000 0.1 1000000 1000 0.1 1000000 1000 0.1 1000000 1000 0.1 1000000 1000 0.1 W sec W W W W W Comment Secondary Secondary Secondary Secondary Secondary Secondary Modbus Module #36 Holding Register : Realtime Data Voltage, Current, Frequency (Float) Modbus Register Parameter name Vln_a Vln_b Vln_c Vln_avg Vll_ab Vll_bc Vll_ca Vll_avg I_a I_b I_c I_avg Modicom Format 4600146002 4600346004 4600546006 4600746008 4600946010 4601146012 4601346014 4601546016 4601746018 4601946020 4602146022 46023- Data Type Range DWord Float Primary Voltage Volts DWord Float Primary Voltage Volts DWord Float Primary Voltage Volts DWord Float Primary Voltage Volts DWord Float Primary Voltage Volts DWord Float Primary Voltage Volts DWord Float Primary Voltage Volts DWord Float Primary Voltage Volts DWord Float Primary Current Amp. DWord Float Primary Current Amp. DWord Float Primary Current Amp. DWord Float Primary Current Amp. Hex 0x17700x1771 0x17720x1773 0x17740x1775 0x17760x1777 0x17780x1779 0x177A0x177B 0x177C0x177D 0x177E0x177F 0x17800x1781 0x17820x1783 0x17840x1785 0x1786- Default value Len 76 Units Comment with Runtime display with Runtime display with Runtime display with Runtime display with Runtime display with Runtime display with Runtime display with Runtime display with Runtime display with Runtime display with Runtime display with Runtime 46024 4602546026 4602746028 I_n Freq 0x1787 0x17880x1789 0x178A0x178B DWord Float DWord Float Primary Current Amp. Hz display with Runtime display with Runtime display Modbus Module #37 Holding Register : Realtime Data Power Result (Float) Modbus Register Parameter name KW_a KW_b KW_c KW_tot KVAR_a KVAR_b KVAR_c KVAR_tot KVA_a KVA_b KVA_c KVA_tot Modicom Format 4602946030 4603146032 4603346034 4603546036 4603746038 4603946040 4604146042 4604346044 4604546046 4604746048 4604946050 4605146052 Len Data Type DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float Hex 0x178C0x178D 0x178E0x178F 0x17900x1791 0x17920x1793 0x17940x1795 0x17960x1797 0x17980x1799 0x179A0x179B 0x179C0x179D 0x179E0x179F 0x17A00x17A1 0x17A20x17A3 Range Default value Units Comment with Runtime display with Runtime display with Runtime display with Runtime display with Runtime display with Runtime display with Runtime display with Runtime display with Runtime display with Runtime display with Runtime display with Runtime display Modbus Module #38 Holding Register : Realtime Data Power Factor & Phase Angle (Float) Modbus Register Parameter name PF_true_a PF_ true_b PF_ true_c PF_ true_avg PhaseAngle_V_a PhaseAngle_V_b PhaseAngle_V_c PhaseAngle_I_a PhaseAngle_I_b PhaseAngle_I_c Pre_Demand_KW* Reserved Reserved Modicom Format 4605346054 4605546056 4605746058 4605946060 4606146062 4606346064 4606546066 4606746068 4606946070 4607146072 4607346074 4607546076 4607746078 Len Hex 0x17A40x17A5 0x17A60x17A7 0x17A80x17A9 0x17AA0x17AB 0x17AC0x17AD 0x17AE0x17AF 0x17B00x17B1 0x17B20x17B3 0x17B40x17B5 0x17B60x17B7 0x17B80x17B9 0x17BA0x17BB 0x17BC0x17BD Data Type DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float 77 Range Default value Units Comment with Runtime display with Runtime display with Runtime display with Runtime display with Runtime display Modbus Module #39 Holding Register : Realtime Data Energy (Float) Modbus Register Parameter name KWH_del KWH_rec KWH_tot KWH_net KVARH_ lagging KVARH_ leading KVARH_tot KVARH_net KVAH Modicom Format 4607946080 4608146082 4608346084 4608546086 4608746088 4608946090 4609146092 4609346094 4609546096 Len Data Type DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float DWord Float Hex 0x17BE0x17BF 0x17C00x17C1 0x17C20x17C3 0x17C40x17C5 0x17C60x17C7 0x17C80x17C9 0x17CA0x17CB 0x17CC0x17CD 0x17CE0x17CF Range Default value Units Comment with Runtime display with Runtime display with Runtime display with Runtime display with Runtime display with Runtime display with Runtime display with Runtime display Modbus Module #40 Holding Register : Realtime data Demand* Modbus Register Parameter name Demand_KW Demand_Remain_Time Modicom Format 4609746098 46099 Len Data Type DWord Float Word UInt Hex 0x17D00x17D1 0x17D2 Range Default value Units Comment sec Modbus Module #41 Holding Register : AI Result Modbus Register Parameter name Modicom Format Len Hex Data Type Range Default value Units Comment AI1 Value 46100 0x17D3 Word UInt 0~65535 optional AI2 Value 46101 0x17D4 Word UInt 0~65535 optional AI3 Value 46102 0x17D5 Word UInt 0~65535 optional AI4 Value 46103 0x17D6 Word UInt 0~65535 optional 78