How to Adjust the Entire Measurement Chain
Filter
Definition of a digital filters for the measured data used for the
adjustment. This filter can be used to suppress disturbances.
•
Type
Selection of the filter type
Available selections:
- No filtering
- Low-pass
- High-pass
- Band-pass
•
Lower limit
Definition of the lower cutoff frequency for the band-pass or the
range limits for high-pass or low-pass
•
Upper limit
Definition of the upper cutoff frequency for the band-pass or the
range limits for high-pass or low-pass
Presettings
Definition of external settings which affect the adjustment procedure:
•
Trigger threshold
Definition of the trigger threshold, at which the measurement is
started,
•
Setpoint value
Definition of the value to which to tune the measurement,
•
Control
Control display for the adjustment.
After configuring the measurement quantities for the adjustment, the
adjustment procedure itself must be defined. For this purpose, the lower
portion of the dialog contains three more input boxes referring to all
channels.
Fig. 84: Configuration dialog for universal channel settings
imc WAVE User's Manual