Download Manual
Transcript
The data format of the emergency object data follows the structure shown bellow. Byte 0 1 Content Emergency Error Code 2 3 4 5 6 Error register Manufacturer specific Error Field 7 Each bit on the error register is defined as follows. The I-7232D only supports bit 0, bit 4 and bit 7. Bit Meaning 0 Generic error 1 Current 2 Voltage 3 Temperature 4 Communication error (overrun, error state) 5 Device profile specific 6 Reserved (always 0) 7 Manufacturer specific I-7232D CANopen/Modbus RTU Gateway user manual (Version 1.02, December/24/2008) ------135