TR515 User’s Manual
Set group-1 registers (‘C’, 43H)
Possible error codes: 04, 07
Command
CRR,reg_data
Reply
A
RR- register number (group-1) in Hex form (00H…FFH); reg_data- the data for the register to
be set
This command is used to set one of the TR515 “group-1 registers”. Registers are actually
functioning parameters (Settings). Complete description of all available registers can be found in
Section 4.
Get group-1 registers (‘B’, 42H)
Possible error codes: 04, 07
Command
BRR
Reply
Areg_datacc
RR- register number (group-1) in Hex form (00H…FFH), reg_data is the data stored in the
register, cc- checksum
This command is used to retrieve the data contained in the designated “group-1 registers”.
Registers are actually functioning parameters (settings). Complete description of all available
registers can be found in Section 4.
Set group-2 registers (‘P’, 50H)
Possible error codes: 04, 07
Command
PRR,reg_data
Reply
A
RR- register number (group-2) in Hex form (00…FFH), reg_data is the data for the register to
be set