Diagnostics and troubleshooting 8.4 Error correction Byte Bit STEP 7 online message 13 1 FM positioning, error in absolute value encoder FM 352-5 fault/error description SSI frame error The red IOF LED is on. What the diagnostic fault/error means Possible causes of error The SSI encoder data does not Faulty wiring from the match the expected format for FM 352-5 encoder interface to the type encoder that was set. the encoder. The SSI encoder data is not being received by the FM 352-5. The terminals are not screwed tight. The terminal strip is not seated Note: This diagnostics interrupt correctly. must be enabled before it can The wrong encoder be reported. parameters have been selected for the encoder used. The encoder connecting cables are too long. The encoder is faulty. 13 3 FM positioning, voltage monitor sensing Encoder sensor supply fault (overload) The red IOF LED is on. and The red 24VF LED is on. The 24 V DC or 5 V DC encoder supply is shorted or overloaded. Faulty wiring from the FM 352-5 encoder interface to the encoder. Other FM positioning diagnostics are invalid if this error occurs. The encoder is overloading or shorting the 24 V DC or 5 V DC supply. Note: This diagnostics interrupt must be enabled before it can The red 5VF LED is on. be reported. or 13 4 FM positioning, voltage monitoring +/15V Missing encoder supply The 24 V input to the FM 352-5 Incorrect wiring of the 24 V voltage (3L) 3L is not present or is below supply to the FM 352-5 3L specified minimum voltage. terminal. The red IOF LED is on. Short-circuit or overload at the 5 VDC encoder supply. The voltage is not 20.4 to 28.8 V at the 3L terminal. Other FM positioning diagnostics are invalid if this error occurs. The terminals are not screwed tight. The terminal strip is not seated Note: This diagnostics interrupt correctly. must be enabled before it can The 5 V DC supply wiring is be reported. incorrect. Short-circuit or overload at the 5 VDC encoder supply. 19 2 Channel 0 digital output short circuit 20 2 Channel 1 . . . 21 2 Channel 2 . . . 22 2 Channel 3 . . . 23 2 Channel 4 . . . 24 2 Channel 5 . . . 25 2 Channel 6 . . . 26 2 Channel 7 . . . Channel x is overloaded. The red IOF LED is on. The FM 352-5 output Qx is shorted or has been overloaded. The connecting wires or the load have intermittent or continuous faults. This diagnostics function is only activated if the channel is enabled and a fault has occurred. The load is above the maximum current rating. The output is switching beyond the maximum specified Note: This diagnostics interrupt operating frequency. must be enabled before it can be reported. FM 352-5 high-speed Boolean processor Operating Manual, 05/2011, A5E00131318-04 197