Parameters Parameter list r0944 CO: Counter for fault buffer changes / Fault buff change Access level: 3 Calculated: - Data type: Unsigned16 Can be changed: - Scaling: - Data set: - Units group: - Unit selection: - Min - Max - Factory setting - Description: Displays fault buffer changes. This counter is incremented every time the fault buffer changes. Dependency: Refer to: r0945, r0947, r0948, r0949, r2109 r0945[0...63] Fault code / Fault code Access level: 3 Calculated: - Data type: Unsigned16 Data set: - Can be changed: - Scaling: - Units group: - Unit selection: - Min - Max - Description: Displays the numbers of faults that have occurred. Dependency: Refer to: r0947, r0948, r0949, r2109, r2130, r2133, r2136 Factory setting - Notice: The properties of the fault buffer should be taken from the corresponding product documentation. Note: The buffer parameters are cyclically updated in the background (refer to status signal in r2139). Fault buffer structure (general principle): r0945[0], r0949[0], r0948[0], r2109[0] --> actual fault case, fault 1 ... r0945[7], r0949[7], r0948[7], r2109[7] --> actual fault case, fault 8 r0945[8], r0949[8], r0948[8], r2109[8] --> 1st acknowledged fault case, fault 1 ... r0945[15], r0949[15], r0948[15], r2109[15] --> 1st acknowledged fault case, fault 8 ... r0945[56], r0949[56], r0948[56], r2109[56] --> 7th acknowledged fault case, fault 1 ... r0945[63], r0949[63], r0948[63], r2109[63] --> 7th acknowledged fault case, fault 8 r0946[0...65534] Fault code list / Fault code list Access level: 3 Calculated: - Data type: Unsigned16 Can be changed: - Scaling: - Data set: - Units group: - Unit selection: - Min - Max - Factory setting - Description: Lists the fault codes stored in the drive unit. Dependency: The parameter assigned to the fault code is entered in r0951 under the same index. r0947[0...63] Fault number / Fault number The indices can only be accessed with a valid fault code. Description: Access level: 2 Calculated: - Data type: Unsigned16 Can be changed: - Scaling: - Data set: - Units group: - Unit selection: - Min - Max - Factory setting - This parameter is identical to r0945. © Siemens AG 2012 All Rights Reserved SINAMICS G120C List Manual (LH13), 01/2012, A5E03052632B AB 1-95
Related documents
List Manual G120C
SINAMICS G120C SINAMICS
ComBridge Studio Visual Editor V 1.6.6 User Manual
Display - Internet
Bunn A-10 Specifications
Diagnostics Manual - Service, Support
Manual - AudioVisual Online
5 - Advanced Test Equipment Rentals
Descarga
Conversores de frequência montados em unidade de
Siemens CU230P-2 Technical data
Siemens SINAMICS G120C