Download List Manual G120C
Transcript
Parameters List of parameters p8991 USB memory access / USB mem acc Access level: 3 Calculated: - Data type: Integer16 Can be changed: T Scaling: - Dyn. index: - Units group: - Unit selection: - Func. diagram: - Min 1 Max 2 Factory setting 1 Description: Selects the storage medium for access via the USB mass storage. Value: 1: 2: Note: A change only becomes effective after a POWER ON. Memory card Flash r/w internal The parameter is not influenced by setting the factory setting. p8999 USB functionality / USB Fct Access level: 4 Calculated: - Data type: Integer16 Can be changed: T Scaling: - Dyn. index: - Units group: - Unit selection: - Func. diagram: - Min 1 Max 3 Factory setting 3 Description: Setting the USB functionality. Value: 1: 2: 3: Note: COMM: Commissioning. USS commissioning via the virtual COM port Only memory access USB commissioning and memory access A change only becomes effective after a POWER ON. The parameter is not influenced by setting the factory setting. p9400 Description: Safely remove memory card / Mem_card rem Access level: 2 Calculated: - Data type: Integer16 Can be changed: T Scaling: - Dyn. index: - Units group: - Unit selection: - Func. diagram: - Min 0 Max 100 Factory setting 0 Setting and display when memory card is "removed safely". Procedure: Setting p9400 = 2 results in a value of 3 --> The memory card can be removed safely. After removal the value sets itself to 0 automatically. Setting p9400 = 2 results in a value of 100 --> The memory card cannot be removed safely. Removal may destroy the file system on the memory card. It may be necessary to set p9400 = 2 again. Value: 0: 1: 2: 3: 100: No memory card inserted Memory card inserted Request "safe removal" of the memory card "Safe removal" possible "Safe removal" not possible due to access Dependency: Refer to: r9401 Notice: Removing the memory card without a request (p9400 = 2) and confirmation (p9400 = 3) may destroy the file system on the memory card. The memory card will then no longer work properly and must be replaced. Note: The status when the memory card is being "removed safely" is shown in r9401. Re value = 0, 1, 3, 100: These values can only be displayed, not set. © Siemens AG 2010 - 2013 All Rights Reserved SINAMICS G120C List Manual (LH13), 01/2013, A5E03052632B AC 1-269
Related documents
List Manual G120C - Service, Support
SINAMICS G120C SINAMICS
Kerweb - Schneider Electric
Display - Internet
5 - Advanced Test Equipment Rentals
PACSystems RX3i PROFINET Scanner
FL SWITCH GHS 4G/12(-L3)
3.6l engine controls and fuel troublesho... 127KB Oct 17 2012 12:25
Manual at elektron.se
View User Manual
G-Stomper User Manual - PLANET
Siemens SINAMICS G120C