Download Product Reference Manual - NFS Professional Services

Transcript
Product Reference Manual
Alarm Text:
4. SNMP-Based Management
Trunk LOS Alarm.
Status Changes:
Condition:
Near-end LOS
Alarm Status:
Critical
Condition:
End of LOS
Alarm Status:
Cleared
Corrective Action:
Ensure the trunk is properly connected.
Table 4-52: acTrunksAlarmNearEndLOF Alarm Trap
Alarm:
acTrunksAlarmNearEndLOF
OID:
1.3.6.1.4.1.5003.9.10.1.21.2.0.50
Default Severity:
Critical
Event Type:
communicationsAlarm
Probable Cause:
lossOfFrame
Alarm Text:
Trunk LOF Alarm.
Status Changes:
Condition:
Near end LOF
Alarm Status:
Critical
Condition:
End of LOF
Alarm Status:
Cleared
Corrective Action:
Ensure the trunk is connected to a proper follow up device. Ensure correct clocking setup.
Table 4-53: acTrunksAlarmRcvAIS Alarm Trap
Alarm:
acTrunksAlarmRcvAIS
OID:
1.3.6.1.4.1.5003.9.10.1.21.2.0.51
Default Severity:
Critical
Event Type:
communicationsAlarm
Probable Cause:
receiveFailure
Alarm Text:
Trunk AIS Alarm
Status Changes:
Condition:
Receive AIS
Alarm Status:
Critical
Condition:
End of AIS
Alarm Status:
Cleared
Corrective Action:
None
Version 5.6
89