Download Netra Proxy Cache Array User`s Manual
Transcript
Test Objects The test objects listed below are shipped with the Netra Proxy Cache product. Their output is displayed in the Host Status page that you invoke from the Array Status page. cache_connect_test An object of type ConnectTest (5). Tests the TCP port used by the proxy cache service (8080). Also tests the service address(es) and control address used by the proxy cache service. The test object instance is configured to test persistent TCP connections. The parameters for this test object are as follows: ConnectTest cache_connect_test port=8080 check_addr=0.0.0.0 interval=10 retries=3 retry_interval=2 reset_min_interval=60 monitor_object=cache_monitor max_connect=99999999 check_control=true persistent_connection=true connection_test_object=cache_http_test cache_process_test An object of type ProcessTest (5). Tests for the presence of the process associated with the proxy cache service. The parameters for this test object are as follows: ProcessTest cache_process_test process_id_script="/etc/init.d/scalr.cache getpid" interval=2 retries=3 retry_interval=2 reset_min_interval=60 cache_test An object of type AndTest (5). Combines the outputs from cache_connect_test, cache_process_test, and service_interface_test. Reports failure to the monitor object (cache_monitor) if any of these “child” test objects returns failure. The parameters for this test object are as follows: AndTest cache_test test_objects=cache_connect_test,cache_process_test reset_script="/etc/init.d/scalr.cache restart" reset_min_interval=60 monitor_object=cache_monitor 156 Netra Proxy Cache Array User’s Manual ♦ Revision A, March 1998