Download VIP5: Lubrication System Controller
Transcript
9.3 PARAMETERS AND VALUES The following table explains the parameters and possible values of the VIP5 selecting basic or extended menu. PARAMETER NAME DEFAULT VALUE DESCRIPTION SELECTS THE OPERATING MODE: Flow monitoring mode MODE CYCLE Lubrication Cycle completed when the cycle sensor confirms correct lubrication FLOW CYCLE SEP INVE.Wait .null. Waiting time for inversion command and pump 1s - 1h X X SEP DUAL Dual Line Pressure switches X FLOW Progressive Cycle switch SEP X TIMER/NO CONTROL TIMER PS PS SELECTS THE CYCLE MONITORING: Timer only Pressure switch CYCLE PULSE DUAL TYPE (Basic) APPLICABILITY PULSE Both Standby and Lubrication Phase determined by external signal. VALUES/ RANGE X Determines Standby Phase Timing PAUSE BY TIMER PAUSE TIM. (Basic) 6m 00s CYCLE TOUT 30 sec LUBE TIME (Basic) 30 sec LUBE CYCLES 1 START IN Resume PRELUBE 0 Time based Standby Time Whichever of above 2 events occurs first. Counter Time & A set number of external PULSE signals Counter By PULSE signals. However, if PAUSE TIM. is reached, an alarm will be given Standby Timer setting. Null means the standby phase will be skipped Timeout counter determines how long to wait for cycle completion before a timeout alarm is generated. In timer Mode, how long the pump will run. Number of Lubrication Cycles to complete a Lubrication Phase Determines state at power on: TOUT & Counter Null – 99h 00m 1s-1h X X X X X X 0s – 99h X X X X X X X 1 – 250 X X X X Start in Lubrication Phase Lube X X X X Resume from power down state Resume Number of Prelube Cycles 0 - 250 X X X X X X X X X X X X X X X X X X X X How REMOTE ALARM is managed ALARM Standard Relay is powered off during alarm Standard Relay is powered On during alarm Inverted A Pulse Coded Alarm signal is given ( for details see section 10.3) Determines what Alarm conditions should stop the VIP5 Lubrication cycles. STOP PUMP (Basic) On all Continuous Coded Never stop the lubrication cycle On None All alarm conditions On All All but min Level stops the Vip5 All but min Level Only minimum level alarm stops the VIP5 Min level only All but Maximum Level All but Max level Pump output can be constant signal, pulsed signal or synchronized with control signal (see next 3 parameters) Continuous Pulsed Synchronized X PUMP TON 3.0 Sets the ON value of the pump pulse. 0.1-25.0s X X X X X X PUMP TOFF 2.0 Sets the OFF value of the pump pulse. 0.1-25.0s X X X X X X Null - 2 min X X X X WAIT TIME BOOST CYCLES 10s 1 Time between two Lubrication Cycles within the Lubrication Phase In a SEP mode, If P2 input is closed the LUBE CYCLES values is increased by this value contained in this setting X 1 - 250 X X X 21/29