Download COMPASS-1 - ADCS

Transcript
The red marked window number one is supposed to drive the stepping motor of the
winding unit. This section is actually able to drive the stepping motor in both rolling
directions, but because of safety reasons only the winding direction is activated. The
second section allows a very fine drive of the linear actuator of the guidance unit. The
particular direction of motion is adjustable with (the) two arrows, whereby the step size
of the motions is manually adjustable from one to 100 steps. For a proper guidance
calibration run the linear actuator must be to his absolute zero point which need to be
countersigned with pushing of the button “Lin=0”. The operation borders of the
guidance are adjusted manually by the turning points of the traverse paths of the
guidance unit. The lower reversal point must be tuned manually as a minimum value
which is set by pushing the button “Set Min” at the user surface. The second reversal
point can also be appointed manually but with the knowledge about the defined coil
width, allows the software the definition of the maximum value by entering the size of
the coil width which is displayed in figure 10-5. The minimum and maximum values
can be checked by using the “Move Min” and “Move Max” buttons.
104