Download MicroBar User Manual

Transcript
11.
MACHINE FUNCTIONS MESSAGES
DISPLAY
CAUSE
EFFECT
SOLUTION
NOTE
GROUNDS DRAWER FULL Grounds drawer full. The Keys delivering coffee based Pull out the grounds drawer
number of coffee grounds in drinks are blocked.
and empty it into a garbage
the drawer has reached the
bag. Put the drawer back into
number set during programplace, when the display reads:
ming stage.
ENGLISH
GROUNDS DRAWER OUT Grounds drawer out of place. Keys delivering coffee based Insert the grounds drawer into
drinks are blocked.
its special slot.
OF PLACE
Should this alarm turn on
during the delivery of a coffee
based drink:
• up until brewing, the alarm
is displayed but the drink
will be delivered;
• after brewing, the cycle in
progress will be suspended.The coffee cycle will
recom-mence only when
the drawer has been put
back in its place.
Should this alarm turn on
during the group movement
phase:
• the movement will be interrupted
When the drawer is back in
its place, the reset group
will be repeated.
FRONT PANEL POSITION Front panel open.
The machine functions are Close the front panel.
blocked.
53