Download MACHINES TYPE

Transcript
QUASAR cod. 2744
PRE-SITE WORK BY CUSTOMER
After the acknowledgment of order and in due time, all the technical documentation necessary to arrange the
installation of the plant is submitted to the Customer.
-
Instructions for equipment and component movement
-
Overall dimensions diagram
See chap.2 - 6
(with the indication of the eventual parts at Customer's charge
-
See chap.6
Foundations diagram
(with the indication of the fixing means eventually at Customer's charge)
See chap.2 - 6
Pneumatic and electrical diagrams
See chap.5
ELECTRICAL POWER REQUIREMENTS
QUASAR 250 Installed power
2,1 Kw
QUASAR 600 Installed power
3,5 Kw
Monophase with ground wire current supply +10% 220V 50Hz - (110V/60Hz option)
QUASAR 1000 – 1200 Installed power
7 Kw
3-Phase with ground wire current supply +10% 400V/3 50Hz
COMPRESSED AIR LINE (only for machines with pneumatic heads or extensometer MICRON and PLAST)
Pressure
Instantaneous absorption
5 : 8 bar
8 m3/h
Average absorption
0,1 m3/h
LUBRICANTS
Recommended type:
LUBCON TURMOGREASE HIGHSPEED L252 (manual lubricator)
OIL
Oil needed for hydraulic closing or hydraulically controlled heads
Recommended type:
MOBIL DTE25 ISO HM46
QUASAR 250 – 600
=~ 20 kg
QUASAR 1000 – 1200
=~ 40 kg
(See Lubricants comparison table)
ASSEMBLY TOOLING
Assembly/disassembly of the plant and the equipments for maintenance, do not require special tools.
The usual tools of the technicians will be sufficient.