Download LISA-U series - U-Blox
Transcript
LISA-U series - System Integration Manual An additional external antenna is connected to an additional SMA connector provided on the motherboard for the Rx diversity antenna of LISA-U230 modules. Since an external antenna is used, the antenna port can be separated from the enclosure port. The reference design is not enclosed in a box so that the enclosure port is not indentified with physical surfaces. Therefore, some test cases cannot be applied. Only the antenna port is identified as accessible for direct ESD exposure. The u-blox LISA-U series reference designs implement all the ESD precautions described in section 2.5.3. u-blox LISA-U series reference designs ESD immunity test results are reported in the Table 55, according to test requirements stated in the CENELEC EN 61000-4-2 [12], ETSI EN 301 489-1 [13], ETSI EN 301 489-7 [14] and ETSI EN 301 489-24 [15]. Category Application Ref. Design Immunity Level Contact Discharge to coupling planes (indirect contact discharge) Enclosure All +4 kV / -4 kV Contact Discharges to conducted surfaces (direct contact discharge) Enclosure port All Not Applicable Test not applicable to u-blox reference design because it does not provide enclosure surface. The test is applicable only to equipments providing conductive enclosure surface. Main Antenna port LISA-U1 series Not Applicable Test not applicable to the u-blox reference design because it provides antenna with insulating surface. The test is applicable only to equipments providing antenna with conductive surface. LISA-U2 series +4 kV / -4 kV Test applicable to u-blox reference design because it provides antenna with conductive & insulating surfaces. The test is applicable only to equipments providing antenna with conductive surface. Rx Div Antenna port LISA-U230-01S +4 kV / -4 kV Test applicable to u-blox reference design because it provides antenna with conductive & insulating surfaces. The test is applicable only to equipments providing antenna with conductive surface. Enclosure port All Not Applicable Test not applicable to the u-blox reference design because it does not provide an enclosure surface. The test is applicable only to equipments providing insulating enclosure surface. Main Antenna port LISA-U1 series +8 kV / -8 kV Test applicable to the u-blox reference design because it provides antenna with insulating surface. The test is applicable only to equipments providing antenna with insulating surface. LISA-U2 series +8 kV / -8 kV Test applicable to u-blox reference design because it provides antenna with conductive & insulating surfaces. The test is applicable only to equipments providing antenna with insulating surface. LISA-U230-01S +8 kV / -8 kV Test applicable to u-blox reference design because it provides antenna with conductive & insulating surfaces. The test is applicable only to equipments providing antenna with insulating surface. Air Discharge at insulating surfaces Rx Div Antenna port Remarks Table 55: Enclosure ESD immunity level of u-blox LISA-U1 series and LISA-U2 series modules reference designs UBX-13001118 - R17 Advance information Design-In Page 147 of 190