Vertical range is not within 90 2 degree with large deviation 8 9 10 11 12 13 Self-test is normal, but cannot control Insensitive control of dome device Call out function fails Auto action of dome device periodically One dome working well while the other does not under identical operaion Fault occurs when the dome device is in tilt movement. It may be caused by obstacle of camera of other object, which lead to early tilt movement Wrong setting Improper connection of control cable Overload or too long distance transmission Improper contact of control cable slip ring is demage RS-485 protective discharge arresters broken System failure caused by noise interference No transmission auto “call back” function is set to the dome device Something wrong with the setting or wiring 25 Check and adjust the mechanical installation Set the protocol, baud rate and address of dome device Check the circuit Add driver Check the circuit Replace slip ring Mostly happen in the connection Change 485 protective discharge arresters Restart the dome device Called this setting check the setting and wiring again V1.1