Download SYS-405 User Manual

Transcript
SYS-405 User Manual
2.7
Ethernet
The two Ethernet ports are labeled ENET-1 and ENET-2 (due to space constraints on the faceplate), but the term Ethernet is used in this Manual.
ETHERNET
Name
Layout
Additional Information
Two Intel I210 Gigabit Ethernet controllers provide standard IEEE 1588 and 802.1AS protocol time-stamping.
Each Ethernet interface includes 10/100/1000 MB multi-speed, full, and half-duplex operation.
Ethernet
[J11, J13]
The SYS-405 is equipped with an Ethernet GPIO connector at J20, which is associated with ENET-2 at J13.
Reference power to J20 is controlled by jumper settings on JP8 (next page).
Ethernet (GPIO)
Controller
[J20]
Connector Reference
PCB Connector
Mating Connector
Crimp Connector
MFR/Part Number
Molex/87832-1020
Molex/51110-1050
Molex/50394-8051
WinSystems Part Number
G650-2010-0H0
N/A
N/A
6
2014-07-21
Page 15 of 39