Download LS Drive Series iG5A Catalog
Transcript
www.lsis.com Compact & Powerful Drive iG5A 0.4~1.5kW (0.5~2HP) 1phase 200~230Volts 0.4~22kW (0.5~30HP) 3Phase 200~230Volts 0.4~22kW (0.5~30HP) 3Phase 380~480Volts Drive Starvert iG5A LS Starvert iG5A is very competitive in its price and shows an upgraded functional strength. User-friendly interface, extended drive ranges up to 22kW, superb torque competence and small size of iG5A provides an optimum use environment. Standard compliance Compactness iG5A High performance Userfriendliness & Easy maintenance 2 Compact & Powerful Drive iG5A Contents 4 8 9 11 13 15 16 18 20 23 25 42 43 Overview Model & Type Standard Specifications Wiring Terminal Configurations Keypad Features Parameter Setting Trial Run Dimensions Braking Resistors and Peripheral Devices Function List Protective Functions Fault Remedy Drive Starvert iG5A Series 3 iG5A Powerful & Upgraded Performance iG5A provides sensorless vector control, PID control, and ground-fault protection through powerful built-in functions. Sensorless vector control Ground-fault protection during running The ground-fault protection of output terminal is possible during running. Vector Control Mode: Auto tuning Measure maximum Condition: Sensorless torque (%) at each speed (1/5/10/20/30/40/50/60Hz) Speed (Hz) Torque (%) The built-in sensorless vector control provides the superb speed control and powerful high torque. Speed vs Torque Characteristics Analog control from -10V to 10V Inputting analog signals from -10V to 10V provides user-friendly operation. +10 Forward Reverse -10 Built-in PID control The built-in PID function enables to control flow-rate, oil-pressure, temperature, etc without any extra controller. PID control Pl control PI Built-in dynamic braking circuit The built-in dynamic braking circuit minimizes deceleration time via braking resistors. Speed Built-in 485 communication The built-in RS-485 communication supports remote control and monitoring between iG5A and other equipment. Wide product range iG5A consists of the product range from 0.4 to 22KW. 4 With braking resistor Normal state Reducing deceleration time Time Compact & Powerful Drive iG5A RS-485 communication Connected to PC RS-485 - 232C converter Monitoring Checking operation status (Voltage, Current, Frequency, etc) Checking modified parameters Windows support Remote Control Convenient remote control to modify operation status (Forward/Reverse operation, Frequency, etc) Easy parameter setting Available to control up to 31 Drives RS-485, Modbus communication Connected to XGT panel Monitoring Checking operation time Automatic list-up of trip record Language support (Korean, English, Chinese) Remote Control Convenient remote control to modify operation status (Forward/Reverse operation, Frequency, etc) Easy parameter setting Available to control up to 31 Drives RS-485, Modbus communication Drive Starvert iG5A Series 5 iG5A User-friendly Interface & Easy Maintenance The parameter setting becomes easier by adopting the 4 directions key. And iG5A supports easy maintenance via diagnosis and fan changeable structure. Diagnosis of output module Through easy parameter setting, iG5A can diagnose the status of output module. Easy change of fan iG5A is designed to be the fan changeable structure in preparation for a fan breakdown. Cooling fan control By controlling the cooling fan, iG5A provides a virtually quiet environment according to the status of operation. User-friendly interface The 4 directions key provides easy handling and monitoring. External loader (Optional) The external loader away from a panel enables to control and monitor conveniently. And the parameters made by external loader can be copied and applicable to other Drives. Loader type + External type (Optional) Model name INV, REMOTE KPD 2M (SV-iG5A) INV, REMOTE KPD 3M (SV-iG5A) INV, REMOTE KPD 5M (SV-iG5A) 6 Remarks 2m 3m 5m Compact & Powerful Drive iG5A Compact Size The compact size achieves cost-efficiency and various applications. Same height from 0.4 to 4.0kW (128mm) Global standard compliance CE UL Global standard iG5A series complies with CE and UL standards. PNP/NPN input Both PNP and NPN inputs become possible and these enable to use the outer power. To do so, users will be given wider choices of selecting the controller. Drive Starvert iG5A Series 7 iG5A Model & Type Applicable motor ranges 1 Phase 200V 3 Phase 200V 3 Phase 400V 0.4kW (0.5HP) SV004iG5A-1 SV004iG5A-2 SV004iG5A-4 0.75kW (1HP) SV008iG5A-1 SV008iG5A-2 SV008iG5A-4 1.5kW (2HP) SV015iG5A-1 SV015iG5A-2 SV015iG5A-4 2.2kW (3HP) SV022iG5A-2 SV022iG5A-4 3.7kW (5HP) SV037iG5A-2 SV037iG5A-4 4.0kW (5.4HP) SV040iG5A-2 SV040iG5A-4 5.5kW (7.5HP) SV055iG5A-2 SV055iG5A-4 7.5kW (10HP) SV075iG5A-2 SV075iG5A-4 11.0kW (15HP) SV110iG5A-2 SV110iG5A-4 15.0kW (20HP) SV150iG5A-2 SV150iG5A-4 18.5kW (25HP) SV185iG5A-2 SV185iG5A-4 22.0kW (30HP) SV220iG5A-2 SV220iG5A-4 SV 015 iG5A STARVERT Motor rating (kW) (004: 0.4kW~220: 22kW) iG5A series Input voltage (1: 1 phase 200~230[V], 2: 3 phase 200~230[V], 4: 3 phase 380~480[V]) 8 2 Compact & Powerful Drive iG5A Standard Specifications 1 Phase 200V SV iG5A-1 004 008 0.5 1 2 0.4 0.75 1.5 0.95 1.9 3.0 (HP) Max. capacity 1) (kW) Capacity (kVA) 2) FLA (A) 3) Output rating 3 phase 200~230V 5) Max voltage 1phase 200~230 VAC (+10%, -15%) Rated voltage Input rating 8 5 400 [Hz] 4) 2.5 Max frequency 015 50~60 [Hz] (±5%) Rated frequency Cooling method Forced air cooling Weight (kg) 1.84 1.12 0.76 3 Phase 200V SV iG5A-2 (HP) Max. capacity 1) (kW) Capacity (kVA) 2) FLA (A) 3) Output rating 004 008 015 022 037 040 055 075 110 150 185 220 0.5 1 2 3 5 5.4 7.5 10 15 20 25 30 0.4 0.75 1.5 2.2 3.7 4.0 5.5 7.5 11 15 18.5 22 0.95 1.9 3.0 4.5 6.1 6.5 9.1 12.2 17.5 22.9 28.2 33.5 2.5 5 8 12 16 17 24 32 46 60 74 88 4) 400 [Hz] 3 phase 200~230V 5) Max frequency Max voltage 3 phase 200~230 (+10%, -15%) Rated voltage Input rating Rated frequency Cooling method Weight (kg) 50~60 [Hz] (±5%) N/C 6) 0.76 0.77 1.12 1.84 1.89 1.89 004 008 015 022 037 Forced air cooling 3.66 3.66 9.0 9.0 13.3 13.3 040 055 075 110 150 185 220 3 Phase 400V SV Max. capacity 1) Output rating iG5A-4 (HP) 0.5 1 2 3 5 5.4 7.5 10 15 20 25 30 (kW) 0.4 0.75 1.5 2.2 3.7 4.0 5.5 7.5 11 15 18.5 22 Capacity (kVA) 2) 0.95 1.9 3.0 4.5 6.1 6.5 9.1 12.2 18.3 22.9 29.7 34.3 FLA (A) 1.25 2.5 4 6 8 9 16 24 30 39 45 9.0 9.0 13.3 13.3 3) Max frequency 3 phase 380~480V 5) Max voltage Input rating Weight (kg) 3 phase 380~480 VAC (+10%, -15%) Rated voltage Rated frequency Cooling method 12 400 [Hz] 4) 50~60 [Hz] (±5%) N/C 6) 0.76 0.77 1.12 1.84 1.89 1.89 Forced air cooling 3.66 3.66 1) Indicate the maximum applicable motor capacity when using 4 pole LS standard motor. 2) Rated capacity is based on 220V for 200V series and 440V for 400V series. 3) Refer to 15-3 of userʼs manual when carrier frequency setting (39) is above 3kHz. 4) Max. frequency setting range is extended to 300Hz when H40 (Control mode select) is set to 3 (Sensorless vector control). 5) Max. output voltage cannot be higher than the input voltage. It can be programmable below input voltage. 6) Self-Cooling Drive Starvert iG5A Series 9 iG5A Control Standard Specifications Control method V/F, Sensorless vector control Frequency setting resolution Digital command: 0.01Hz Analog command: 0.06Hz (Max. freq.: 60Hz) Frequency accuracy Digital command: 0.01% of Max. output frequency Analog command: 0.1% of Max. output frequency V/F pattern Linear, Squared, User V/F Overload capacity 150% per 1 min. Torque boost Manual/Auto torque boost Dynamic braking Max. braking torque 20% 1) Max. Duty 150% when using optional DB resistor 2) Operation mode Keypad/ Terminal/ Communication option/ Remote keypad selectable Frequency setting Analog: 0~10V, -10~10V, 0~20mA Digital: Keypad Operation features PID, Up-down, 3-wire NPN/PNP selectable Operation Input Multi-function terminal P1~P8 Open collector terminal Output Multi-function relay Analog output (AM) Protective function Environ ment FWD/REV RUN, Emergency stop, Fault reset, Jog operation, Multi-step Frequency-High, Mid, Low, Multi-step Accel/Decel-High, Mid, Low, DC braking at stop, 2nd motor select, Frequency UP/Down, 3-wire operation, External trip A, B, PID-Drive (V/F) operation bypass, Option-drive (V/F) operation bypass, Analog Hold, Accel/Decel stop Fault output and drive status output (N.O., N.C.) Less than AC 250V, 1A; Less than DC 30V, 1A 0~10Vdc (less than 10mA): Output freq, Output current, Output voltage, DC link selectable Trip Over voltage, Under voltage, Over current, Ground fault current detection, Drive overheat, Motor overheat, Output phase open, Overload protection, Communication error, Loss of speed command, Hardware fault, Fan trip Alarm Stall prevention, Overload Momentary power loss Below 15 msec.: Continuous operation (Should be within rated input voltage, rated output power.) Above 15 msec.: Auto restart enable Protection degree IP 20, NEMA1 (Optional) Ambient temp -10℃~50℃ Storage temp -20℃~65℃ Humidity Altitude/Vibration Below 90% RH (No condensation) Below 1,000m, 5.9m/sec 2 (0.6G) Atmospheric pressure 70~106 kPa Location Protected from corrosive gas, Combustible gas, Oil mist or dust 1) Means average braking torque during Decel to stop of a motor. 2) Refer to Chapter 16 of userʼs manual for DB resistor specification. 10 Less than DC 24V, 50mA Compact & Powerful Drive iG5A Wiring 0.4~7.5kW DB resistor (Optional) 3 phase AC input (Rated input voltage) B1 B2 U R S V T W G Ground 24 24V output P1 FX (Forward run) P2 RX (Reverse run) AM Multi-function analog output signal: 0~10V CM CM Input signal common P3 BX (Emergency stop) P4 RST (Trip reset) P5 JOG (Jog operation) 3A A contact output CM Input signal common 3C A/B contact common P6 Multi-step freq. - Low P7 Multi-step freq. - Middle 3B B contact output P8 Multi-step freq. - High MO Multi-function open collector output Potentiometer (1kohm, 1/2W) VR 10V power supply for potentiometer V1 Freq. Setting Voltage signal input: -10~10V I Freq. Current signal input: 0~20mA CM Input signal common MG MO Common S+ S- RS-485 communication terminal Drive Starvert iG5A Series 11 iG5A Wiring 11.0~22.0kW DC reactor 3 phase AC input (Rated input voltage) P1(+) DB resistor (Optional) B1 B2 N(-) R U S V T W G Ground 24 24V output AM Multi-function analog output signal: 0~10V P1 FX (Forward run) P2 RX (Reverse run) CM CM Input signal common P3 BX (Emergency stop) P4 RST (Trip reset) P5 JOG (Jog operation) 3A A contact output CM Input signal common 3C A/B contact common P6 Multi-step freq. - Low P7 Multi-step freq. - Middle 3B B contact output P8 Multi-step freq. - High MO Multi-function open collector output Potentiometer (1kohm, 1/2W) VR 10V power supply for potentiometer V1 Freq. Setting Voltage signal input: -10~10V I S+ Freq. Current signal input: 0~20mA CM Input signal common 12 MG MO Common S- RS-485 communication terminal Compact & Powerful Drive iG5A Wiring Specifications for power terminal block wiring R T B1 B2 U V R S T W B1 B2 U V B2 U W V R(L1) R, S, T wire SV0004iG5A-1 W R T B1 • 2.2~4.0kW (3 phase) R S • 11~22kW (3 phase) • 5.5kW~7.5kW (3 phase) B1 • 1.5kW (1 phase) • 0.4kW~1.5kW (3 phase) • 0.4kW~0.75kW (1 phase) U, V, W wire S(L2) T(L3) P1(+) Ground wire B2 U V W T B1 B2 U V W B1 B2 N(-) U V W mm2 AWG mm2 AWG mm2 AWG Terminal Screw Size Screw Torque (kgf.cm) / lb-in 2 14 2 14 3.5 12 M3.5 10/8.7 SV0008iG5A-1 2 2 14 3.5 12 M3.5 10/8.7 SV0015iG5A-1 14 2 14 2 14 3.5 12 M4 15/13 SV0004iG5A-2 2 2 14 3.5 12 M3.5 10/8.7 SV0008iG5A-2 14 2 14 2 14 3.5 12 M3.5 10/8.7 SV0015iG5A-2 2 2 14 3.5 12 M3.5 10/8.7 SV0022iG5A-2 14 2 14 2 14 3.5 12 M4 15/13 SV0037iG5A-2 3.5 3.5 12 3.5 12 M4 15/13 SV0040iG5A-2 12 3.5 12 3.5 12 3.5 12 M4 15/13 SV0055iG5A-2 5.5 5.5 10 5.5 10 M5 32/28 SV0075iG5A-2 10 8 8 8 8 5.5 10 M5 32/28 SV0110iG5A-2 14 14 6 14 6 M6 30.7/26.6 SV0150iG5A-2 6 22 22 4 14 6 M6 30.7/26.6 SV0185iG5A-2 4 30 2 30 2 22 4 M8 30.5/26.5 SV0220iG5A-2 38 30 2 22 4 M8 30.5/26.5 SV0004iG5A-4 2 2 14 2 14 2 14 M3.5 10/8.7 SV0008iG5A-4 2 2 14 2 14 M3.5 10/8.7 SV0015iG5A-4 14 2 14 2 14 2 14 M4 15/13 SV0022iG5A-4 2 2 14 2 14 M4 15/13 SV0037iG5A-4 14 2 14 2 14 2 14 M4 15/13 SV0040iG5A-4 2 2 14 2 14 M4 15/13 SV0055iG5A-4 14 3.5 12 2 14 3.5 12 M5 32/28 SV0075iG5A-4 3.5 12 3.5 12 3.5 12 M5 32/28 10 8 8 M5 30.7/26.6 30.7/26.6 SV0110iG5A-4 5.5 SV0150iG5A-4 10 5.5 14 8 8 8 8 M5 SV0185iG5A-4 6 14 6 8 8 14 6 M6 30.5/26.5 SV0220iG5A-4 22 4 14 6 14 6 M6 30.5/26.5 Drive Starvert iG5A Series 13 iG5A Terminal Configuration Control terminal specifications MO MG 3A Terminal P1~P8 3B 3C Description Multi-function input T/M 1-8 24 P5 CM P1 P6 P2 CM P7 P8 Wire size (mm2) P3 VR P4 S- S+ I AM V1 Torque (Nm) 1.5 M2.6 0.4 1.5 M2.6 0.4 Stranded 1.0 1.0 Specification CM Common terminal VR Power supply for external potentiometer 1.0 1.5 M2.6 0.4 V1 Input terminal for voltage operation 1.0 1.5 M2.6 0.4 Max. input voltage: -12V~+12V input I Input terminal for current operation 1.0 1.5 M2.6 0.4 0~20mA input Internal resistor: 500ohm AM Multi-function analog output terminal 1.0 1.5 M2.6 0.4 Max. output voltage: 11V Max. output current: 100mA MO Multi-function terminal for open collector 1.0 1.5 M2.6 0.4 Below DC 26V,100mA Ground terminal for external power supply 1.0 1.5 M2.6 0.4 24V external power supply 1.0 1.5 M2.6 0.4 Max. output current: 100mA Multi-function relay output A contact 1.0 1.5 M2.6 0.4 Below AC 250V, 1A Multi-function relay output B contact 1.0 1.5 M2.6 0.4 Below DC 30V, 1A Common for multi-function relays 1.0 1.5 M2.6 0.4 MG 24 3A 3B 3C 1) Use the recommended tightening torque when securing terminal screws. ※ When you use external power supply (24V) for multi-function input terminal (P1~P8), apply voltage higher than 12V to activate. ※ Tie the control wires more than 15cm away from the control terminals. Otherwise, it interferes front cover reinstallation. 14 1) Screw size Single wire Output voltage: 12V Max. output current: 100mA Potentiometer: 1~5kohm Compact & Powerful Drive iG5A Keypad Features Display KEY LED 1) Description Term RUN Run key Run command STOP/RESET STOP/RESET key STOP: Stop command during operation, RESET: Reset command when a fault occurs. ▲ Up key Down key Used to scroll through codes or increase parameter value ▼ ▶ Right key Used to jump to other parameter groups or move a cursor to the right to change the parameter value ◀ Left key Used to jump to other parameter groups or move a cursor to the left to change the parameter value ● Enter key FWD Forward run Used to set the parameter value or save the changed parameter value REV Reverse run Lit during reverse run Run key Lit during operation Setting Lit during parameter setting RUN SET Used to scroll through codes or decrease parameter value Lit during forward run 1) 4 LEDs above are set to blink when a fault occurs. ENT RESET 65.6 STOP RUN 2-Φ4.5 36.2 FWD REV 72.4 SET RUN 3.4 95 83 70 C L Dimensions 5 2.1 13.9 23.1 Drive Starvert iG5A Series 15 iG5A Moving to Other Groups Parameter groups There are 4 different parameter groups in iG5A series as shown below. Parameter group Description Drive group Basic parameters necessary for the drive to run. Parameters such as Target frequency, Accel/Decel time settable. Function group 1 Basic function parameters to adjust output frequency and voltage. Function group 2 Advanced function parameters to set parameters for such as PID Operation and second motor operation. I/O (Input/Output) group Parameters necessary to make up a sequence using multi-function input/output terminal. Moving to other groups Moving to other groups using the Right (▶) key Moving to other groups using the Left (◀) key 1) 1) Target frequency can be set at 0.0 (the 1st code of drive group). Even though the preset value is 0.0, it is user-settable. The changed frequency will be displayed after it is changed. 16 1) Compact & Powerful Drive iG5A When changing ACC time from 5.0 sec to 16.0 sec 1 2 •In the first code “0.00”, press the Up (▲) key once to go to the second code. •ACC [Accel time] is displayed. •Press the Ent (●) key once. 3 •Preset value is 5.0, and the cursor is in the digit 0. •Press the Left (◀) key once to move the cursor to the left. 4 •The digit 5 in 5.0 is active. Then press the Up (▲) key once. 5 •The value is increased to 6.0 •Press the Left (◀) key to move the cursor to the left. 6 •0.60 is displayed. The first 0 in 0.60 is active. •Press the Up (▲) key once. 7 •16.0 is set. •Press the Ent (●) key once. •16.0 is blinking. 1) •Press the Ent (●) key once again to return to the parameter name. 8 •ACC is displayed. Accel time is changed from 5.0 to 16.0 sec. 1) Pressing the Left (◀)/Right (▶)/Up (▲)/Down (▼) key while a cursor is blinking will cancel the parameter value change. Pressing the Ent (●) key in this status will enter the value into memory. ※ In step 7, pressing the Left (◀) or Right (▶) key while 16.0 is blinking will disable the setting. Code change in Drive group 1 •In the 1st code in Drive group “0.00”, press the Up (▲) key once. 2 •The 2nd code in Drive group “ACC”is displayed. •Press the Up (▲) key once. 3 •The 3rd code “dEC” in Drive group is displayed. •Keep pressing the Up (▲) key until the last code appears. 4 •The last code in Drive group “drC” is displayed. •Press the Up (▲) key again. 5 •Return to the first code of Drive group. •Use Down (▼) key for the opposite order. Drive Starvert iG5A Series 17 iG5A Trial Run Multi-step operation + Run/Stop via FX/RX + Max. frequency change Operation condition Operation command: Run/Stop via FX/RX Frequency command: Multi-step operation [Low (20), Middle (30), High (80)] Max. frequency change: From 60Hz to 80Hz Wiring P1 (Forward) S1 P2 (Reverse) S2 3 phase AC input P6 (Low) S3 S V T W S/W P8 (High) S5 U G P7 (Middle) S4 R P1 (Forward) P2 (Reverse) CM P6 (Low) P7 (Middle) P8 (High) CM 1. Please make sure that R, S, T are connected to 3 phase AC input, and U, V, W are also motor connection terminals. 2. After supplying the power, please set the frequency of multi-step among Low, Middle, and High. VR 3. If P1 (FX) turns on, the motor operates in forward. And after turning off, it stops according to the deceleration time. CM V1 4. If P2 (RX) turns on, the motor operates in reverse. And after turning off, it stops according to the deceleration time. Parameter setting 18 Step Command Code Default After change 1 Max. frequency change (FU1) F21 Change Max. frequency. Description 60Hz 80Hz 2 Multi-step frequency (DRV) st1 Set ‛Low’ step. 10Hz 20Hz 3 Multi-step frequency (DRV) st2 Set ‛Middle’ step. 20Hz 30Hz 4 Multi-step frequency (I/O) I30 Set ‛High’ step. 30Hz 80Hz 5 Forward run (P1: FX) I17 The default is FX. This value may change. FX FX 6 Reverse run (P2: RX) I18 The default is RX. This value may change. RX RX Compact & Powerful Drive iG5A Potentiometer (Volume) + Run/Stop via FX/RX + Accel/Decel time change Operation condition Operation command: Run/Stop via FX/RX Frequency command: 0~60Hz analog input via potentiometer Accel/Decel time: Accel-10sec, Decel-20sec Wiring Potentiometer 1~5kohm, 1/2W 3 2 Motor VR R S T G 3 phase AC input V1 1 CM U V W 0~60Hz P1 (FX) Forward P2 (RX) Reverse CM 1. Please make sure that R, S, T are connected to 3 phase AC input, and U, V, W are also motor connection terminals. 2. After supplying the power, please set the frequency of multi-step among Low, Middle, and High. 3. If P1 (FX) turns on, the motor operates in forward. And after turning off, it stops according to the deceleration time. VR V1 CM Potentiometer 1~5kohm, 1/2W 4. If P2 (RX) turns on, the motor operates in reverse. And after turning off, it stops according to the deceleration time. 5. Control the motorʼs speed via potentiometer. Parameter setting Step Command Code Description 1 Operation command (DRV group) Drv Turn on/off motor via terminal. 1 (FX/RX-1) 1 (FX/RX-1) 2 Analog input (DRV group) Frq Change keypad command to analog voltage command. 0 (Keypad-1) 3 (V1: 0~10V) 3 Accel/Decel time (DRV group) ACC dEC Set Accel time to 10sec in ACC 5sec (Accel) 10sec (Decel) 10sec (Accel) 20sec (Decel) 4 Forward run (P1: FX) I17 The default is FX. This value may change FX FX 5 Reverse run (P2: RX) I18 The default is RX. This value may change. RX RX Set Decel time to 20sec in dEC. Default After change Drive Starvert iG5A Series 19 iG5A Dimensions SV004iG5A-2 / SV008iG5A-2, SV004iG5A-4 / SV008iG5A-4 W A A W1 H1 Φ H D B W1 mm (inches) Drive model (kW) W (mm) W1 (mm) H (mm) H1 (mm) D (mm) SV004IG5A-2 SV008IG5A-2 SV004IG5A-4 SV008IG5A-4 0.4 0.75 0.4 0.75 70 70 70 70 65.5 65.5 65.5 65.5 128 128 128 128 119 119 119 119 130 130 130 130 Φ 4.0 4.0 4.0 4.0 A (mm) B (mm) (kg) 4.5 4.5 4.5 4.5 4.0 4.0 4.0 4.0 0.76 0.77 0.76 0.77 SV015iG5A-2 / SV015iG5A-4 W W1 A1 A H1 Φ H D B W1 mm (inches) 20 Drive model (kW) W (mm) W1 (mm) H (mm) H1 (mm) D (mm) Φ A (mm) B (mm) (kg) SV015IG5A-2 SV015IG5A-4 1.5 1.5 100 100 95.5 95.5 128 128 120 120 130 130 4.5 4.5 4.5 4.5 4.5 4.5 1.12 1.12 Compact & Powerful Drive iG5A SV022iG5A-2 / SV037iG5A-2 / SV040iG5A-2, SV022iG5A-4 / SV037iG5A-4 / SV040iG5A-4 W A Φ H1 C L H D B B W1 mm (inches) Drive model (kW) W (mm) W1 (mm) H (mm) H1 (mm) D (mm) Φ A (mm) B (mm) (kg) SV022IG5A-2 SV037IG5A-2 SV040IG5A-2 SV022IG5A-4 SV037IG5A-4 SV040IG5A-4 2.2 3.7 4.0 2.2 3.7 4.0 140 140 140 140 140 140 132 132 132 132 132 132 128 128 128 128 128 128 120.5 120.5 120.5 120.5 120.5 120.5 155 155 155 155 155 155 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 1.84 1.89 1.89 1.84 1.89 1.89 SV055iG5A-2 / SV075iG5A-2, SV055iG5A-4 / SV075iG5A-4 W A Φ W A H1 H D B B W mm (inches) Drive model (kW) W (mm) W1 (mm) H (mm) H1 (mm) D (mm) Φ A (mm) B (mm) (kg) SV055IG5A-2 SV075IG5A-2 SV055IG5A-4 SV075IG5A-4 5.5 7.5 5.5 7.5 180 180 180 180 170 170 170 170 220 220 220 220 210 210 210 210 170 170 170 170 4.5 4.5 4.5 4.5 5 5 5 5 4.5 4.5 4.5 4.5 3.66 3.66 3.66 3.66 Drive Starvert iG5A Series 21 iG5A Dimensions SV110iG5A-2 / SV150iG5A-2 / SV110iG5A-4 / SV150iG5A-4 W A W1 Φ A H1 H D B B W1 mm (inches) Drive model (kW) W (mm) W1 (mm) H (mm) H1 (mm) D (mm) Φ A (mm) B (mm) (kg) SV110iG5A-2 SV150iG5A-2 SV110iG5A-4 SV150iG5A-4 11.0 15.0 11.0 15.0 235 235 235 235 219 219 219 219 320 320 320 320 304 304 304 304 189.5 189.5 189.5 189.5 7.0 7.0 7.0 7.0 8.0 8.0 8.0 8.0 7.0 7.0 7.0 7.0 9.00 9.00 9.00 9.00 SV0185iG5A-2 / SV0220iG5A-2 / SV0185iG5A-4 / SV0220iG5A-4 W Φ A W1 A H1 H D B W1 B mm (inches) 22 Drive model (kW) W (mm) W1 (mm) H (mm) H1 (mm) D (mm) Φ A (mm) B (mm) (kg) SV185iG5A-2 SV220iG5A-2 SV185iG5A-4 SV220iG5A-4 18.5 22.0 18.5 22.0 260 260 260 260 240 240 240 240 410 410 410 410 392 392 392 392 208.5 208.5 208.5 208.5 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 13.3 13.3 10.0 10.0 Compact & Powerful Drive iG5A Braking Resistors and Peripheral Devices Braking resistors Voltage 100% braking Drive Resistor [Ω] 400 200 100 60 40 30 20 15 11 9 8 1,800 900 450 300 200 120 90 60 45 35 30 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11.0 15.0 18.5 22.0 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11.0 15.0 18.5 22.0 200V Series 400V Series Watt [W]1) 50 100 200 300 500 700 1,000 1,400 2,000 2,400 2,800 50 100 200 300 500 700 1,000 1,400 2,000 2,400 2,800 150% braking Resistor [Ω] 300 150 60 50 33 20 15 10 8 5 5 1,200 600 300 200 130 85 60 40 30 20 20 Watt [W] 1) 100 150 300 400 600 800 1,200 2,400 2,400 3,600 3,600 100 150 300 400 600 1,000 1,200 2,000 2,400 3,600 3,600 1) The wattage is based on Enable Duty (%ED) with continuous braking time 15sec. Breakers Voltage 1-Phase 200V 3-Phase 200V 3-Phase 400V Capacity [kW] 0.4 0.75 1.5 0.4 0.75 1.5 2.2 3.7 4 5.5 7.5 11 15 18.5 22 0.4 0.75 1.5 2.2 3.7 4 5.5 7.5 11 15 18.5 22 Model Circuit Breaker (MCCB) Model Rated Current [A] ABS33c UTE100 ABS33c ABS53c ABS63c ABS103c ABS203c ABS33c ABS53c ABS63c ABS103c 5 10 15 5 10 15 20 30 30 50 60 100 125 150 175 3 5 10 10 15 20 30 30 50 60 75 100 UTE100 UTS150 UTS250 UTE100 Rated Current [A] 15 15 15 15 15 15 20 30 30 50 60 90 125 150 175 15 15 15 15 15 20 30 30 50 60 80 90 Leakage Breaker (ELCB) Model Rated Current [A] EBS33c EBS33c EBS53c EBS63c EBS103c EBS203c EBS33c EBS53c EBS63c EBS103c 5 10 15 5 10 15 20 30 30 50 60 100 125 150 175 5 5 10 10 15 20 30 30 50 60 75 100 Note) 1. The capacity of the MCCB should be 1.5 to 2 times the rated output current of the drive. 2. Use an MCCB keep the drive from faulting out instead of using overheat protection (150% for one minute at the rated output current.) 3. In case magnetic contactor is used on single-phase product, wire R and T phases. Magnetic Contactor (MC) Model Rated Current [A] MC-6a 9 MC-9a, MC-9b 11 MC-18a, MC-18b 18 MC-6a 9 MC-9a, MC-9b 11 MC-18a, MC-18b 18 MC-22b 22 32 MC-32a 32 MC-50a 55 MC-65a 65 MC-85a 85 MC-130a 130 MC-150a 150 MC-185a 185 7 MC-6a 7 MC-9a, MC-9b 9 MC-12a, MC-12b 12 18 MC-18a, MC-18b 18 MC-22b 22 MC-32a 32 MC-50a 50 MC-65a 65 MC-75a 75 MC-85a 85 Drive Starvert iG5A Series 23 iG5A Braking Resistors and Peripheral Devices Fuses & AC reactors Model 004iG5A-1 008iG5A-1 015iG5A-1 004iG5A-2 008iG5A-2 015iG5A-2 022iG5A-2 037iG5A-2 040iG5A-2 055iG5A-2 075iG5A-2 110iG5A-2 150iG5A-2 185iG5A-2 220iG5A-2 004iG5A-4 008iG5A-4 015iG5A-4 022iG5A-4 037iG5A-4 040iG5A-4 055iG5A-4 075iG5A-4 110iG5A-4 150iG5A-4 185iG5A-4 220iG5A-4 24 AC external fuse Current [A] 10 A 10 A 15 A 10 A 10 A 15 A 25 A 30 A 30 A 30 A 50 A 70 A 100 A 100 A 125 A 5A 10 A 10 A 10 A 20 A 20 A 20 A 30 A 35 A 45 A 60 A 70 A Voltage [V] 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V AC reactor DC reactor 4.20 mH, 3.5 A 2.13 mH, 5.7 A 1.20 mH, 10 A 4.20 mH, 3.5 A 2.13 mH, 5.7 A 1.20 mH, 10 A 0.88 mH, 14 A 0.56 mH, 20 A 0.56 mH, 20 A 0.39 mH, 30 A 0.28 mH, 40 A 0.20 mH, 59 A 0.15 mH, 75 A 0.12 mH, 96 A 0.10 mH, 112 A 18.0 mH, 1.3 A 8.63 mH, 2.8 A 4.81 mH, 4.8 A 3.23 mH, 7.5 A 2.34 mH, 10 A 2.34 mH, 10 A 1.22 mH, 15 A 1.14 mH, 20 A 0.81 mH, 30 A 0.61 mH, 38 A 0.45 mH, 50 A 0.39 mH, 58 A 0.74 mH, 56 A 0.57 mH, 71 A 0.49 mH, 91 A 0.42 mH, 107 A 2.76 mH, 29 A 2.18 mH, 36 A 1.79 mH, 48 A 1.54 mH, 55 A Compact & Powerful Drive iG5A Function List Drive Group LED display Address for communication Parameter name Min/Max range dEC A100 [Frequency 0 ~ 400 command][Hz] A101 [Accel time] A102 [Decel time] 0 ~ 6000 [Sec] A103 [Drive mode] 0~3 A104 [Frequency setting method] 0~7 A105 A106 frequency 1] [Multi-Step frequency 2] St3 [Multi-Step A107 frequency 3] CUr A108 [Output current] rPM A109 [Motor RPM] A10A vOL A10B FX: Run/Stop enable 10.0 O 1 X Keypad setting 1 3 V1 2: 0 ~ +10 [V] 4 RX: Reverse rotation select Digital 1 Analog 5 Keypad setting 2 V1 1: -10 ~ +10 [V] Terminal I: 0 ~ 20 [mA] Terminal V1 setting 1 + Terminal I Terminal V1 setting 2+ Terminal I 7 RS485 communication 9 Set to Field Bus communication 1) 8 [Multi-Step RX: Motor reverse run Set to Field Bus communication 1) 6 FX: Motor forward run RS485 communication 2 dCL O Run/Stop via Run/Stop key on the keypad 1 Terminal operation 2 0 5.0 Accel/Decel time 0. 4 St2 During Multi-Accel/Decel operation, this parameter serves as 3 St1 O During Multi-step operation: 0 Frq During Run: Output Frequency It cannot be set greater than F21- [Max frequency]. drv During Stop: Frequency Command Multi-step frequency 0. 0.00 to output. ACC Adj. during run This parameter sets the frequency that the drive is commanded 0.00 Factory defaults Description [Hz] [Drive DC link voltage] [User display select] Torque 30.00 O - - - - - - vOL - This parameter displays the item selected at H73- [Monitoring tOr O Displays DC link voltage inside the drive. Output power 20.00 Displays the number of Motor RPM. Output voltage 10.00O Displays the output current to the motor. POr Sets Multi-Step frequency 3 during Multi-step operation. vOL Sets Multi-Step frequency 2 during Multi-step operation. item select]. X Digital Volume Sets Multi-Step frequency 1 during Multi-step operation. 0 ~ 400 0 1) This function can be available with iG5A Communication Option Module. Drive Starvert iG5A Series 25 iG5A Function List Drive Group LED display nOn Address for communication Parameter name A10C [Fault Display] drC A10D Min/Max range Displays the types of faults, frequency and operating status at the time of the fault A10E motor rotation select] F, r to either 0 or 1. F r 0 [Drive mode 2] 0~3 4 0 Frq2 1) A10F [Frequency setting 0~7 method 2] Run/Stop via Run/Stop key on the keypad RX: Motor reverse run FX: Run/Stop enable RX: Reverse rotation select RS-485 communication Set to Filed Bus Communication 3) Terminal I: 0 ~ 20 [mA] Terminal V1 setting 2+ Terminal I 7 RS485 communication 9 Set to Filed Bus Communication 3) Digital Volume If H58 is 0, it is expressed as a [Hz] unit. PID control If H58 is 1, it is expressed as a [%] unit. It indicates a feedback amount in PID control. 0 X 0.00 0 - - Factory defaults Adj. during run Sets the parameter code number to jump. 1 O 0 Fwd and rev run enable Reverse run disable If H58 is 0, it is expressed as a [Hz] unit. If H58 is 1, it is expressed as a [%] unit. amount Analog 5 In [Hz] unit, you canʼt set Max. frequency more than (F21). 0~100 [%] In [%] unit, 100% means Max. frequency. Terminal V1 setting 1 + Terminal I 4 value setting feedback X Fbk 2) A111 1 V1 2: 0 ~ +10 [V] V1 1: -10 ~ +10 [V] 0~400[Hz] or O 3 Keypad setting 2 PID control standard F Keypad setting 1 A110 - Digital 1 8 - FX: Motor forward run 6 2) Reverse 2 rEF Forward 1 Terminal operation 2 3 Adj. during run Sets the direction of motor rotation when drv - [Drive mode] is set [Direction of drv2 Factory defaults Description 1) Only displayed when one of the Multi-function input terminals 1-8 [I17~I24] is set to “22”. 2) It is indicated when H49(PID control selection) is 1. 3) This function can be available with iG5A Communication Option Module. Function group 1 LED display F0 F1 F2 F3 26 Address for communication Parameter name Min/Max range A200 [Jump code] 0 ~ 71 [Forward/ A201 Reverse run A202 [Accel pattern] A203 [Decel pattern] 0~2 Description 1 2 disable] 0~1 Forward run disable 0 Linear 1 S-curve 0 X 0 X Compact & Powerful Drive iG5A Function group 1 LED display Address for communication Parameter name Min/Max range A204 [Stop mode F 8 1) A208 [DC Brake 0.1 ~ 60 [DC Brake 0 ~ 60 [DC Brake 0 ~ 200 F4 A209 F9 A20A F10 A20B F11 select] start frequency] wait time] 0~3 [Hz] [sec] voltage] [%] [DC Brake time] 0 ~ 60 [sec] [DC Brake start 0 ~ 200 F12 A20C F13 [DC Brake start 0 ~ 60 A20D time] [sec] F14 A20E voltage][%] [Time for magnetizing a motor] A214 [Jog frequency] F20 0 ~ 60 [sec] 0 ~ 400 [Hz] A215 [Max frequency] F21 2) 40 ~ 400 A216 [Base frequency] 30 ~ 400 F22 A217 [Start frequency] F23 A218 F24 F25 F26 F27 F28 F29 3) A219 A21A A21B A21C [Frequency high /low limit select] [Hz] [Hz] 0.1 ~ 10 [Hz] 0~1 [Frequency 0 ~ 400 [Frequency 0.1 ~ 400 high limit] low limit] [Torque Boost select] [Torque boost in forward direction] [Torque boost A21D in reverse direction] [Hz] [Hz] 0~1 0 ~ 15 [%] Description Factory defaults Adj. during run 0 Decelerate to stop 2 Free run to stop 0 X 5.00 X 0.1 X 50 X motor while motor is at a stop. 1.0 X starts to run. 50 X 0 X 1 3 DC brake to stop Power Braking stop This parameter sets DC brake start frequency. It cannot be set below F23 - [Start frequency]. When DC brake frequency is reached, the drive holds the output for the setting time before starting DC brake. This parameter sets the amount of DC voltage applied to a motor. It is set in percent of H33 - [Motor rated current]. This parameter sets the time taken to apply DC current to a This parameter sets the amount of DC voltage before a motor It is set in percent of H33 - [Motor rated current]. DC voltage is applied to the motor for DC Brake start time before motor accelerates. This parameter applies the current to a motor for the set time before motor accelerates during Sensorless vector control. 0.1 X 10.00 O This parameter sets the frequency for Jog operation. It cannot be set above F21 - [Max frequency]. This parameter sets the highest frequency the drive can output. It is frequency reference for Accel/Decel (See H70) 60.00 Caution X Any frequency cannot be set above Max frequency except Base frequency The drive outputs its rated voltage to the motor at this frequency 60.00 X 0.50 X 0 X It cannot be set above F21 - [Max frequency]. 60.00 X It cannot be set above F25 - [Frequency high limit] and below 0.50 X (see motor nameplate). The drive starts to output its voltage at this frequency. It is the frequency low limit. This parameter sets high and low limit of run frequency. This parameter sets high limit of the run frequency. This parameter sets low limit of the run frequency. F23 - [Start frequency]. 0 1 Manual torque boost Auto torque boost This parameter sets the amount of torque boost applied to a motor during forward run. It is set in percent of Max output voltage. This parameter sets the amount of torque boost applied to a motor during reverse run. It is set as a percent of Max output voltage. 1) Only displayed when F 4 is set to 1 (DC brake to stop). 2) If H40 is set to 3 (Sensorless vector), Max. frequency is settable up to 300Hz. 3) Only displayed when F24 (Frequency high/low limit select) is set to 1. 0 X 2 X 2 X Drive Starvert iG5A Series 27 iG5A Function List Function group 1 LED display F30 F31 1) F32 F33 F34 F35 F36 F37 F38 F39 F40 F50 Address for communication A21E [V/F pattern] A21F frequency 1] A220 A221 A222 A223 A224 A225 A226 A232 A233 A234 F54 F55 [Hz] [User V/F ] 0 ~ 100 voltage 1 [User V/F 0 ~ 100 [User V/F [User V/F [User V/F A235 A236 A237 [Electronic 0~1 above those of higher-numbered. 50 ~ 200 [%] [%] This parameter adjusts the amount of output voltage. The set value is the percentage of input voltage. This parameter decreases output voltage according to load status. This parameter is activated when the motor is overheated (timeinverse). continuously for 1 minute. The set value is the percentage of H33 - [Motor rated current]. It cannot be set below F52 - [Electronic thermal level for This parameter sets the amount of current to keep the motor running continuously. It cannot be set higher than F51 - [Electronic thermal level for 1 minute]. Standard motor having cooling fan directly connected to 0 the shaft [Motor cooling warning level] [Overload warning time] 30 ~ 150 [%] 0 ~ 30 [Sec] X 30.00 X 50 X 45.00 X 75 X 60.00 X 100 X 100 X 0 0 0 0 150 0 1000 0 0 signal at a relay or multi-function output terminal (see I54, I55). 150 0 This parameter issues an alarm signal when the current greater 0~1 method] 1A motor using a separate motor to power a cooling fan. [Overload 25 continuous]. 50 ~ 150 X This parameter sets max current capable of flowing to the motor thermal level for continuous] voltage]. 0 ~ 100 thermal select] 15.00 The values of the lower-numbered parameters cannot be set [%] [Hz] [User V/F thermal level for It cannot be set above F21 - [Max frequency]. 0 ~ 400 voltage 4] [Electronic [Hz] [%] frequency 4] 1 minute] {User V/F} {Square} The value of voltage is set in percent of H70 - [Motor rated 0 ~ 100 voltage 3] [Electronic 2 1 [%] 0 ~ 400 frequency 3] X [Hz] [User V/F 0 {Linear} 0 ~ 400 voltage 2] Adj. during run 0 [%] frequency 2] Factory defaults Description 0 ~ 400 It is used only when V/F pattern is set to 2(User V/F) [User V/F 1) Set F30 to 2(User V/F) to display this parameter. 2) Set F50 to 1 to display this parameter. 28 0~2 [Energy-saving 0 ~ 30 A228 level] [%] F53 Min/Max range [Output voltage 40 ~ 110 A227 adjustment][%] F51 2) F52 Parameter name This parameter sets the amount of current to issue an alarm The set value is the percentage of H33- [Motor rated current]. than F54- [Overload warning level] flows to the motor for F55[Overload warning time]. 10 0 Compact & Powerful Drive iG5A Function group 1 LED display F56 F57 F58 Address for communication A238 A239 A23A Parameter name Min/Max range [Overload 0~1 trip select] [Overload 30 ~ 200 [Overload 0 ~ 60 trip level] [%] trip time] [Sec] Factory defaults Adj. during run 1 0 The value is the percentage of H33- [Motor rated current]. 180 0 [Overload trip level] of current flows to the motor for F58- 60 0 Description This parameter turns off the drive output when motor is overloaded. This parameter sets the amount of overload current. This parameter turns off the drive output when the F57[Overload trip time]. during deceleration. A23B [Stall prevention select] 0~7 - - 6 A23C 5 A23F [Stall prevention level] 30 ~ 200 [%] [When Stall limit select [Save up/down frequency select] 0~1 0~1 [Up-down mode A241 select] A242 [Up-down step 0~2 0~400 frequency][Hz] [Draw rate] 0 - 0~100[%] X - - This parameter sets the amount of current to activate stall 150 prevention function during Accel, Constant or Decel run. X The set value is the percentage of the H33- [Motor rated current]. In Stall prevention run during deceleration, if you want to limit output voltage, select 1 This parameter decides whether to save the specified frequency during up/down operation. When 1 is selected, the up/down frequency is saved in F64. Increases goal frequency as a standard of Max. 0 frequency/Min. frequency 1 2 In case of choosing F65 as a 1 or 2, it means increase or decrease of frequency according to up-down input 0 Drive doesnʼt run as a draw mode 2 I(0~20mA) input draw run 1 3 V1(0~10V) input draw run V1(-10~10V) input draw run Sets rate of draw X 0.00 X 0 Increases as many as step frequency according to edge input Available to combine 1 and 2 0 We can select up-down mode among three thing A247 - saves the frequency before the drive stops or decelerated. [Draw run mode A246 0~3 select] - Bit 0 If ʻSave up/down frequencyʼ is selected at F63, this parameter - 7 [Save up/down F64 2) A240 frequency] F71 - - prevention during A23D F61 1) deceleration, voltage F70 - - During constant run During Accel Bit 1 4 F66 1 2 During Decel Bit 2 F65 0 3 F63 decelerating during constant speed run and stops decelerating F60 This parameter stops accelerating during acceleration, F59 X 0.00 X 0 X 0.00 0 1) It is indicated when setting bit 2 of F59 as 1 2) Set F63 to 1 to display this parameter. Drive Starvert iG5A Series 29 iG5A Function List Function group 2 LED display H0 H1 H2 H3 H4 H5 H6 Address for communication Parameter name Min/Max range A300 [Jump code] 0~95 A302 A301 A303 A304 A305 A306 H7 H8 H10 H11 1) H12 H13 H14 H15 H16 H17 H18 H19 H21 - [Fault history 3] Stores information on the types of faults, the frequency, the - latest fault is automatically stored in the H 1- [Fault history 1]. - [Fault history 4] [Fault history 5] - [Reset fault 0~1 history] A308 [Dwell time] A30A [Skip frequency A30B [Skip frequency A30C [Skip frequency A30D A30E A30F current and the Accel/Decel condition at the time of fault. The 0~1 [Skip frequency low limit 2] [Skip frequency [Hz] high limit 2] [Dwell frequency] can be set within the range of F21- [Max frequency] and F23- [Start frequency]. Sets the frequency range to skip to prevent undesirable resonance and vibration on the structure of the machine. The frequency values of the low numbered parameters cannot be set above those of the high numbered ones. Settable within the range of F21 and F23. [Skip frequency [Skip frequency [S-Curve accel/ 1~100 Set the speed reference value to form a curve at the start during [S-Curve accel/ 1~100 Set the speed reference value to form a curve at the end during A311 A312 A313 low limit 3] high limit 3] decel start side] decel end side] [Input/output phase loss protection select] A314 Start select] [Restart after A315 [Power On fault reset selection] [%] accel/decel. If it is set higher, linear zone gets smaller. [%] accel/decel. If it is set higher, linear zone gets smaller. 0~3 0~1 0 Disabled 1 Output phase protection Input phase Input/output phase 2 3 protection protection This parameter is activated when drv is set to 1 or 2 (Run/Stop via Control terminal). Motor starts acceleration after AC power is applied while FX or - nOn - nOn nOn nOn O 5.00 X 0.0 X 0 X 10.00 X 15.00 X 20.00 X 25.00 X 30.00 X 35.00 X 40 X 40 X 0 O 0O RX terminal is ON. This parameter is activated when drv is set to 1 or 2 (Run/Stop 0 ~1 via Control terminal). Motor accelerates after the fault condition is reset while the FX or RX terminal is ON. 1) only displayed when H10 is set to 1. # H17, H18 are used when F2, F3 are set to 1 (S-curve) 30 nOn dwell frequency is applied to the motor during H8- [Dwell time]. A310 O When run frequency is issued, motor starts to accelerate after Run frequency cannot be set within the range of H11 thru H16. 0.1~400 1 0 low limit 1] high limit 1] Adj. during run Clears the fault history saved in H 1-5. 0~10 [sec] Sets the time for dwell operation. select] Sets the code number to jump. - 0.1~400 A307 [Dwell frequency] [Hz] H20 [Fault history 1] [Fault history 2] Factory defaults Description 0 O Compact & Powerful Drive iG5A Function group 2 LED display Address for communication Parameter name Min/Max range This parameter is active to prevent any possible fault when the drive outputs its voltage to the running motor. 1. H20- 2. Restart 3. Operation 4. Normal - 2 - 3 4 [Speed Search 1) A316 0 ~ 15 H22 Select] H25 during Speed A318 [P gain during H26 H27 H30 H31 - 1. H20- [Power On start] A31A A31B A31E A31F 2. Restart after instant power failure - - after fault 6 - - 80~200 search] Speed search] [I gain during speed search] [Number of Auto Restart try] [Auto Restart time] [Motor type select] [Number of motor poles] [%] Bit 1 Bit 0 - - - 8 - 10 - - accel - - - - - - - - - This parameter limits the amount of current during speed search. The set value is the percentage of the H33- [Motor rated current]. 100 O 0~9999 It is the Proportional gain used for Speed Search PI controller. 100 O 0~9999 It is the Integral gain used for Speed search PI controller. 200 O 0 O 1.0 O This parameter sets the number of restart tries after a fault 3. Operation 4. Normal Bit 3 5 Bit 2 O - - 15 [Current level A317 A319 - - 0 - 14 - 13 power failure 12 - Adj. during run accel after fault - - 11 H24 - 9 On start] after instant 7 [Power 0 1 H23 Factory defaults Description 0 ~10 0~60 [sec] occurs. Auto Restart is deactivated if the fault outnumbers the restart tries. This function is active when [drv] is set to 1 or 2 {Run/Stop via control terminal}. Deactivated during active protection function (OHT, LVT, EXT, HWT etc.). This parameter sets the time between restart tries. 0.2 0.2~ 22.0 ~ 22.0 2 ~ 12 0.2kW 2) ~ 7.5 22.0kW X 4 X This setting is displayed via rPM in drive group. 1) Normal acceleration has first priority. Even though #4 is selected along with other bits, Drive performs Speed search #4. 2) H30 is preset based on drive rating. Drive Starvert iG5A Series 31 iG5A Function List Function group 2 LED display Address for communication Parameter name Min/Max range H32 fs = fr - A320 [Rated slip 0 ~ 10 frequency][Hz] Factory defaults Adj. during run 1) 2.33 X Description [ rpm X p ] 120 Where, fs = Rated slip frequency fr = Rated frequency rpm = Motor nameplate RPM p = Number of Motor poles H33 A321 H34 H36 [Motor rated 0.5~150 current] [A] [No Load Motor 0.1~ 50 A322 Current] [A] 50~100 A324 [Motor efficiency] [%] H37 A325 [Load inertia rate] 0~2 H39 H40 A327 [Carrier 1 ~ 15 frequency [kHz] select] A328 [Control mode select] 0~3 H41 H42 [Stator resistance 0 ~ 28 A32A (Rs)] [Ω] H44 H45 2) H46 H47 A329 A32C A32D H49 [Leakage A32F A330 A331 0~1 0~ 300.0 inductance (Lσ )][mH] [Sensorless P gain] [Sensorless A32E I gain] H48 [Auto tuning] [Sensorless torque limit] PWM mode select PID select 0~ 32767 100~220 [%] 0~1 0~1 1) H32 ~ H36 factory default values are set based on OTIS-LG motor. 2) Set H40 to 3 (Sensorless vector control) to display this parameter. 32 Enter the current value detected when the motor is rotating in rated rpm after the load connected to the motor shaft is removed. Enter the 50% of the rated current value when it is difficult to measure H34 - [No Load Motor Current]. Enter the motor efficiency (see motor nameplate). Select one of the following according to motor inertia. 0 1 2 Enter motor rated current on the nameplate. Less than 10 times About 10 times More than 10 times This parameter affects the audible sound of the motor, noise emission from the drive, drive temp, and leakage current. If the set value is higher, the drive sound is quieter but the noise from the drive and leakage current will become greater. 0 1 3 {Volts/frequency Control} {Slip compensation control} {Sensorless vector control} If this parameter is set to 1, it automatically measures 26.3 X 11 X 87 X 0 X 3 O 0 X 0 X This is the value of the motor stator resistance. - X This is leakage inductance of the stator and rotor of the motor. - X P gain for Sensorless control 1000 O I gain for Sensorless control 100 O 180.0 X 0 X 0 X parameters of the H42 and H44. Limits output torque in sensorless mode. If you want to limit a drive leakage current, select 2 phase PWM mode. It has more noise in comparison to Normal PWM mode. 0 1 Normal PWM mode 2 phase PWM mode Selects whether using PID control or not Compact & Powerful Drive iG5A Function group 2 LED display H50 1) H51 H52 H53 H54 H55 H56 Address for communication Parameter name Min/Max range A332 [PID F/B select] 0~1 A333 [P gain for PID] A334 A335 A336 A337 A338 H57 A339 [Differential time 0 ~ 30.0 for PID [sec] for PID (D gain)] [sec] [PID control 0~1 mode select] [PID output 0.1 ~ 400 [Hz] limit] [PID output frequency low 1 Terminal I input (0 ~ 20 mA) Terminal V1 input (0 ~ 10 V) 0.1 ~ 400 [Hz] limit] 0 X 300.0 O 1.0 O 0.0 O This parameter sets the gains for the PID controller. Selects PID control mode 1 0 0 Normal PID control Process PID control This parameter limits the amount of the output frequency through 60.00 X O the PID control. and F23 - [Start frequency]. 0.50 O Loader digital setting 2 0 X I terminal setting: 0~20mA The value is settable within the range of F21 ? [Max frequency] Selects PID standard value. [PID standard 0~4 0 1 value select] 2 4 A33A H60 0.1~32.0 frequency high 0 [%] [Integral time Adj. during run Standard value is indicated in “rEF” of Drive group. H58 0~ 999.9 Factory defaults Description A33C 3 PID control unit select 0~1 [Self-diagnostic 0~3 select] Loader digital setting 1 V1 terminal setting 2: 0~10V Setting as a RS-485 communication Selects a unit of the standard value or feedback amount. 0 Frequency[Hz] 0 Self-diagnostic disabled 1 1 2 3 0 X Percentage[%] IGBT fault/Ground fault Output phase short & open/ Ground fault 0 X Ground fault (This setting is unable when more than 11kW) H61 2) A33D [Sleep delay time] 0~2000[s] Sets a sleep delay time in PID drive. 60.0 X H62 A33E [Sleep frequency] 0~400[Hz] control drive. 0.00 O A33F 35.0 O H63 H64 H65 H66 H67 H70 A340 A341 A342 A343 A346 Sets a sleep frequency when executing a sleep function in PID [Wake up level] [KEB drive select] 0~100[%] Sets a wake up level in PID control drive. [KEB action start level] [KEB action stop level] [KEB action gain] [Frequency Reference for Accel/Decel] You canʼt set more than Max. frequency(F21) 0~1 110~140 [%] 110~145 [%] 1~20000 0~1 Sets KEB drive. 0 X Sets KEB action start level according to level. 125.0 X Sets KEB action stop level according to level. 130.0 X 1000 X 0 X Sets KEB action gain. 0 Based on Max freq (F21) 1 Based on Delta freq. 1) Set H49 to 1 (PID control) to display this parameter. 2) Set H49 as a 1 3): it is indicated when setting H64(KEB drive select) as a 1 (KEB does not operate when cut power after loading ting input (about 10%). Drive Starvert iG5A Series 33 iG5A Function List Function group 2 LED display H71 Address for communication Parameter name Min/Max range 0 [Accel/Decel 1 A347 0~2 time scale] 2 Settable unit: 0.01 second. Settable unit: 0.1 second. Settable unit: 1 second. This parameter selects the parameter to be displayed on the keypad when the input power is first applied. 0 Frequency command 2 Decel time 1 H73 H75 H76 9 10 Motor rpm Drive DC link voltage User display select (H73) 13 15 17 select]. 12 14 16 One of the following can be monitored via vOL - [User display A349 [Monitoring item select] 0~2 A34A [Gain for Motor 1 ~ 1000 operating rate 0~1 [DB resistor 0 ~ 30 A34B A34C rpm display] [DB resistor limit select] operating rate] A34D H77 1) [Cooling fan [Operating H79 Output current 11 H78 Multi-Step frequency 3 8 H74 display] A34E A34F control] method select when cooling fan malfunctions] [S/W version] 0 [%] 0~1 0~1 0 ~ 10.0 Fault display Direction of motor rotation select Output current 2 Motor rpm 2 Drive DC link voltage 2 User display select 2 Output voltage [V] 1 Output power [kW] 2 [%] Torque [kgf, m] This parameter is used to change the motor rotating speed (r/ min) to mechanical speed (m/mi) and display it. 0 0 1 Use DB resistor for the H76 set time. during one sequence of operation. 0 Always ON 1 Keeps ON when its temp is higher than drive protection limit temp. Activated only during operation when its temp is below that of drive protection limit. 0 Continuous operation when cooling fan malfunctions. 1 Operation stopped when cooling fan malfunctions. This parameter displays the drive software version. O Unlimited Set the percent of DB resistor operating rate to be activated O 0 1) Exception: Since SV004iG5A-2/SV004iG5A-4 is Natural convection type, this code is hidden. 34 Multi-Step frequency 2 7 Multi-Step frequency 1 6 0 ~ 15 O Frequency mode 5 [Power on 1 Drive mode 4 A348 Adj. during run Accel time 3 H72 Factory defaults Description 100O 1 O 10O 0 O 0 O 1.0 X Compact & Powerful Drive iG5A Function group 2 LED display Parameter Min/Max name range [2nd motor A351 H81 1) Accel time] 0 ~ 6000 [2nd motor [sec] H82 A352 Decel time] [2nd motor 30 ~ 400 H83 A353 base frequency] [Hz] [2nd motor 0~2 H84 A354 V/F pattern] [2nd motor forward H85 A355 torque boost] 0 ~ 15 [2nd motor reverse [%] H86 A356 torque boost] [2nd motor stall 30~150 H87 A347 prevention level] [%] [2nd motor 50~200 A358 Electronic thermal H88 [%] level for 1 min] [2nd motor H89 Address for communication A359 H90 Electronic thermal level for A35B [Parameter read] 0~1 H92 A35C [Parameter write] 0~1 H93 initialize] 0~5 H94 A35E H95 A35F [Password register] [Parameter lock] 10.0 O 60.00 X 0 X 5 X 5 X 150 X Copy the parameters from drive and save them into remote loader. drive. 0 - 2 Only Drive group is initialized. 4 Only Function group 2 is initialized. O 100O 26.3 X 0 X 0 X Copy the parameters from remote loader and save them into All parameter groups are initialized to factory default 1 value. 0 3 5 0 ~ FFFF O factory default value. [Parameter 5.0 150 This parameter is used to initialize parameters back to the A35D Adj. during run [%] H91 2) This parameter actives when the selected terminal is ON after I17-I24 is set to 12 {2nd motor select}. 50~150 continuous] [2nd motor 0.1~100 A35A rated current] [A] Factory defaults Description X Only Function group 1 is initialized. Only I/O group is initialized. Password for H95-[Parameter lock]. Set as Hexa value. 0O This parameter is able to lock or unlock parameters by typing 0 ~ FFFF password registered in H94. UL (Unlock) L (Lock) Parameter change enable 0 O Parameter change disable 1) It is indicated when choosing I17~I24 as a 12 (2nd motor select). 2) H91,H92 parameters are displayed when Remote option is installed. Drive Starvert iG5A Series 35 iG5A Function List Input/output group LED display I0 I2 I3 I4 I5 I6 I7 I8 I9 I10 I11 I12 I13 I14 I15 I16 I17 I18 I19 I20 Address for communication Parameter name Min/Max range A400 [Jump code] 0 ~ 87 A402 [NV input Min voltage] 0 ~ -10 [V] [Frequency 0 ~ 400 A403 corresponding to I 2] [Hz] A404 [NV input Max voltage] 0 ~ -10 [V] [Frequency 0 ~ 400 A405 corresponding to I 4][Hz] A406 A407 Adj. during run 1 O 0.00 O 0.00 O 10.0 O 60.00 O 10 O 0 O 0.00 O 10 O 60.00 O 10 O 4.00 O 0.00 O 20.00 O 60.00 O activated below half of set value. 0 O Forward run command Sets the code number to jump. Sets the minimum voltage of the NV (-10V~0V) input. Sets the drive output minimum frequency at minimum voltage of the NV input. Sets the maximum voltage of the NV input. Sets the drive output maximum frequency at maximum voltage of the NV input. [Filter time constant 0 ~ 9999 Adjusts the responsiveness of V1 input (0 ~ +10V). for V1 input] [V1 input Min 0 ~ 10 voltage] [V] [Frequency 0 ~ 400 A408 corresponding to I 7][Hz] A409 Factory defaults Description [V1 input Max 0 ~ 10 voltage] [V] [Frequency 0 ~ 400 A40A corresponding to I 9][Hz] Sets the minimum voltage of the V1 input. Sets the drive output minimum frequency at minimum voltage of the V1 input. Sets the maximum voltage of the V1 input. Sets the drive output maximum frequency at maximum voltage of the V1 input. Sets the input sectionʼs internal filter constant for I input. [Filter time A40B constant for I input] 0 ~ 9999 A40C A40D A40E [I input Min 0 ~ 20 Sets the minimum current of I input. [Frequency 0 ~ 400 Sets the drive output minimum frequency at minimum current of I [I input Max 0 ~ 20 Sets the Maximum current of I input. current] [mA] corresponding to I 12][Hz] current] [mA] input. [Frequency 0 ~ 400 A40F corresponding to I 14][Hz] Sets the drive output maximum frequency at maximum current of 1 A410 [Criteria for Analog Input Signal loss] [Multi-function P1 define] A411 A412 A413 A414 0~2 I input. 0 Disabled 2 activated below set value. 0 input terminal Reverse run command 2 Emergency Stop Trip 3 Reset when a fault occurs {RST} 4 Jog operation command 5 Multi-Step freq - Low [Multi-function 6 Multi-Step freq - Mid P4 define] 7 Multi-Step freq - High [Multi-function input terminal P2 define] [Multi-function input terminal P3 define] input terminal 0 ~ 27 * See °∞Chapter 14 Troubleshooting and maintenance°± for External trip A/B contact. * Each multi-function input terminal must be set differently. 36 0 1 1 2 3 O O O O Compact & Powerful Drive iG5A Input/output group LED display I21 I22 I23 Address for communication Parameter name [Multi-function 8 Multi Accel/Decel - Low P5 define] 9 Multi Accel/Decel - Mid [Multi-function 10 Multi Accel/Decel - High P6 define] 11 DC brake during stop [Multi-function 12 2nd motor select P7 define] 13 -Reserved- A415 A416 A417 Min/Max range input terminal input terminal input terminal 14 15 0 ~ 27 -Reserved Up-down 16 I24 I25 I26 A418 External trip: B Contact (EtB) I31 I32 I33 I34 I35 I36 22 25 27 24 26 A419 A41A A41B I30 21 P8 define] A41E [Output terminal constant for Multi-function 1 ~ 15 A423 Accel/Decel Disable Up/Down Save Freq. Initialization JOG-FX JOG-RX P7 P6 P5 P4 BIT2 BIT1 BIT0 P3 [Multi-Step [Hz] [Multi-Accel time 1] [Multi-Decel time 1] [Multi-Accel A424 time 2] 0~ 6000 [sec] P2 BIT0 P1 MO is getting slower. It cannot be set greater than F21 - [Max frequency]. 0 O 0 O If the value is set higher, the responsiveness of the Input terminal [Multi-Step frequency 6] O Analog Hold frequency 4] [Multi-Step A421 frequency 7] A422 2nd Source Input terminal] 0 ~ 400 7 Change from PID operation to V/F operation 3AC [Filtering time O Self-diagnostic function BIT1 status display] [Multi-Step A41F frequency 5] A420 P8 status display] O External trip: A Contact (EtA) BIT7 BIT6 BIT5 BIT4 BIT3 [Input terminal O Frequency decrease command (DOWN) 19 20 input terminal 4 5 Frequency increase (UP) command 3-wire operation 23 I27 [Multi-function Adj. during run 6 17 18 Factory defaults Description 4 O 30.00 O 25.00 O 20.00 O 15.00 O 3.0 O 3.0 4.0 Drive Starvert iG5A Series 37 iG5A Function List Input/output group LED display I37 I38 I39 I40 I41 I42 I43 I44 I45 I46 I47 Address for communication A425 Parameter name Min/Max range [Multi-Decel time 2] [Multi-Accel A426 time 3] [Multi-Decel A427 time 3] A42A [Multi-Accel time 5] 6.0 6.0 0~ 6000 [Multi-Decel A42B time 5] 7.0 8.0 8.0 [Multi-Accel A42E time 7] 9.0 [Multi-Decel A42F time 7] A432 A433 I52 A434 I53 I54 A435 A436 I55 [Analog output item select] [Analog output level adjustment] [Frequency detection level] [Frequency detection 9.0 A437 0~3 10~200 [%] [Hz] bandwidth] output terminal select] [Multi-function relay select] Output item Output to 10[V] 1 150 % 0 Output freq. 2 Output voltage 3 Output current Drive DC link voltage Based on 10V. Cannot be set higher than F21. Max frequency AC 282V DC 400V 400V 0 O 100 O 30.00 O 10.00 O AC 564V DC 800V 0 FDT-1 12 2 FDT-3 1 3 4 0 ~ 19 200V 0 ~ 400 Used when I54 or I55 is set to 0-4. [Multi-function 38 [Multi-Decel A42D time 6] I51 7.0 [sec] [Multi-Accel A42C time 6] 4.0 5.0 [Multi-Accel A428 time 4] [Multi-Decel A429 time 4] Adj. during run 5.0 I50 Factory defaults Description 5 6 7 8 9 FDT-2 FDT-4 FDT-5 Overload (OLt) Drive Overload (IOLt) Motor stall (STALL) Over voltage trip (Ovt) Low voltage trip (Lvt) 17 O Compact & Powerful Drive iG5A Input/output group LED display Address for communication Parameter name Min/Max range I55 10 Drive Overheat (OHt) 12 During Run 11 A437 [Multi-function relay select] 13 0 ~ 19 14 15 16 17 18 19 A438 [Fault relay output] 0~7 I57 A439 I59 I60 I61 select when communication 0~3 error occurs] auto restart try] occurs [Communication 0 ~1 A43C [Drive number] 1 ~ 250 A43D protocol select] [Baud rate] 0~4 I62 A43E occurs 0 - Bit 2 1 - - Bit 1 - - - - - 1 - of frequency command] - 1 - - LS BUS Set for RS485 communication Select the Baud rate of the RS485. 1200 [bps] 2 4800 [bps] 1 2400 [bps] 2 0 O 0 X 1 O 3 O 19200 [bps] Continuous operation at the frequency before its 0 command is lost. 1 9600 [bps] RS485. 0~2 Multi-function output terminal Modbus RTU 0 Bit 0 3 Set communication protocol. 0 - It is used when freq command is given via V1 /I terminal or [Drive mode select after loss Multi-function relay - - Bit 1 0 O low voltage trip Bit 0 - 4 voltage trip 3 H26 - [Number of other than low 2 A43B Brake signal select 2 Warning for cooling fan trip 7 [Output terminal O Multi-function relay select When the 2 17 Wait time for run signal input 6 During speed searching 5 During constant run 4 During Stop When setting the When the trip 3 Adj. during run Command loss I56 Factory defaults Description 0 O Free Run stop (Output cut-off) Decel to stop Drive Starvert iG5A Series 39 iG5A Function List Input/output group LED display I63 I64 Address for communication [Wait time after [Communication A440 I67 I68 I69 I70 I71 I72 I73 I74 I75 I76 I77 I78 I79 I80 I81 This is the time drive determines whether there is the input A441 A442 time setting] [Parity/stop bit setting] [Read address A443 [Read address A445 A446 A447 A448 A449 A44A A44B A44C A44D A44E A44F A450 A451 182 1) A452 [ms] 0~3 A444 2 ~ 100 0 Parity: None, Stop Bit: 1 2 Parity: Even, Stop Bit: 1 1 Parity: None, Stop Bit: 2 Parity: Odd, Stop Bit: 1 5 O O O 7 register 3] [Read address 0~42239 register 5] The user can register up to 8 discontinuous addresses and read them all with one Read command. 8 9 O [Read address 10 register 6] [Read address 11 register 7] [Read address 12 register 8] [Write address 5 register 1] [Write address 6 register 2] [Write address 7 register 3] [Write address [Write address O 6 [Read address register 4] 1.0 5 register 2] [Read address Adj. during run When the protocol is set, the communication format can be set. 3 0~42239 register 5] The user can register up to 8 discontinuous addresses and write them all with one Write command 7 register 7] [Write address current] 5 O [Write address [Brake open 6 register 6] register 8] 8 [Write address 1) It is indicated when choosing I54~I55 as a 19 (Brake signal). 40 Frame communication time register 1] register 4] Factory defaults Description 0.1 ~ 120 frequency command or not. If there is no frequency command A43F loss of frequency [sec] input during this time, drive starts operation via the mode command] selected at I62. I66 Min/Max range I65 Parameter name 8 0~180 [%] Sets current level to open the brake. It is set according to H33ʼs (motor rated current) size 50.0 O Compact & Powerful Drive iG5A Input/output group LED display 183 184 185 186 187 Address for communication A453 A454 A455 ` A456 A457 Parameter name Min/Max range [Brake open 0~10 [Brake open FX 0~400 [Brake open RX 0~400 [Brake close 0~19 [Brake close 0~400 delay time] [s] frequency][Hz] frequency][Hz] delay time] [s] frequency[Hz] Factory defaults Adj. during run Sets Brake open dely time. 1.00 X Sets FX frequency to open the brake 1.00 X Sets RX frequency to open the brake 1.00 X Sets delay time to close the brake 1.00 X Sets frequency to close the brake 2.00 X Description Drive Starvert iG5A Series 41 iG5A Protective Functions Keypad display Protective functions Descriptions The drive turns off its output when the output current of the drive flows more than 200% of the drive rated current. The drive turns off its output when a ground fault occurs and the ground fault current is more than the internal setting value of the drive. The drive turns off its output when the output current of the drive flows more than the rated level (150% for 1 minute). The drive turns off its output if the output current of the drive flows at 150% of the drive rated current for more than the current limit time (1min). The drive turns off its output if the heat sink overheats due to a damaged cooling fan or an alien substance in the cooling fan by detecting the temperature of the heat sink. The drive turns off its output when the one or more of the output (U, V, W) phase is open. The drive detects the output current to check the phase loss of the output. The drive turns off its output if the DC voltage of the main circuit increases higher than 400V when the motor decelerates. This fault can also occur due to a surge voltage generated at the power supply system. The drive turns off its output if the DC voltage is below 180V because insufficient torque or overheating of the motor can occur when the input voltage of the drive drops. The internal electronic thermal of the drive determines the overheating of the motor. If the motor is overloaded, the drive turns off the output. The drive cannot protect the motor when driving a motor having more than 4 poles or multi motors. Drive output is blocked when one of R, S, T is open or the electrolytic capacitor needs to be replaced. Displayed when IGBT damage, output phase short, output phase ground fault or output phase open occurs. Displayed when user-setting parameters fails to be entered into memory. Displayed when an error occurs in the control circuitry of the drive. Displayed when the drive cannot communicate with the keypad. Displayed when the drive and the remote keypad do not communicate with each other. It does not stop drive operation. Displayed after the drive resets the keypad when a keypad error occurs and this .... Displayed when a fault condition occurs in the drive cooling fan. Used for the emergency stop of the drive. The drive instantly turns off the output when the EST terminal is turned on. Caution: The drive starts to regular operation when turning off the EST terminal while FX or RX terminal is ON. When multi-function input terminal (I20-I24) is set to 19 {External fault signal input A: (Normal Open Contact)}, the drive turns off the output. When multi-function input terminal (I20-I24) is set to 19 {External fault signal input B: (Normal Close Contact)}, the drive turns off the output. When drive operation is set via analog input (0-10V or 0-20mA input) or option (RS-485) and no signal is applied, operation is done according to the method set in I62 (Operating method when the frequency reference is lost). 42 Compact & Powerful Drive iG5A Fault Remedy Keypad display Cause Remedy Caution: W hen an overcurrent fault occurs, operation must be started after the cause is removed to avoid damage to IGBT inside the drive. Accel/Decel time is too short compared to the GD2 of the load. Load is greater than the drive rating. Drive output is issued when the motor is free running. Output short circuit or ground fault has occurred. Mechanical brake of the motor is operating too fast. → Increase the Accel/Decel time. → Replace the drive with appropriate capacity. → R esume operation after stopping the motor or use H22 (Speed search). → Check output wiring. → Check the mechanical brake. Ground fault current Ground fault has occurred at the output wiring of the drive. The insulation of the motor is damaged due to heat. → Check the wiring of the output terminal. → Replace the motor. Drive overload Load is greater than the drive rating. Overload trip Torque boost scale is set too large. → U pgrade the capacity of motor and drive or reduce the load weight. → Reduce torque boost scale. Heat sink overheat Cooling system has faults. An old cooling fan is not replaced with a new one. Ambient temperature is too high. → Check for alien substances clogged in the heat sink. → R eplace the old cooling fan with a new one. → Keep ambient temperature under 50°C. Output Phase loss Faulty contact of magnetic switch at output. Faulty output wiring. Cooling fan fault An alien substance is clogged in a ventilating slot. Drive has been in use without changing a cooling fan. → M ake connection of magnetic switch at output of the drive securely. → Check output wiring. → C heck the ventilating slot and remove the clogged substances. → Replace the cooling fan. Decel time is too short compared to the GD2 of the load. Regenerative load is at the drive output. Line voltage is too high. → Increase the Decel time. → Use Dynamic Brake Unit. → Check whether line voltage exceeds its rating. Line voltage is low. Load larger than line capacity is connected to line (ex: welding machine, motor with high starting current connected to the commercial line). Faulty magnetic switch at the input side of the drive. → Check whether line voltage is below its rating. → C heck the incoming AC line. Adjust the line capacity corresponding to the load. Overcurrent Over voltage Low voltage Electronic thermal External fault A contact input Motor has overheated. Load is greater than drive rating. ETH level is set too low. Drive capacity is incorrectly selected. Drive has been operated at low speed for too long. → → → → → → Change a magnetic switch. Reduce load weight and operating duty. Change drive with higher capacity. Adjust ETH level to an appropriate level. Select correct drive capacity. Install a cooling fan with a separate power supply. The terminal set to “18 (External fault- A)" or “19 (External fault-B)” in I20-I24 in I/O group is ON. → E liminate the cause of fault at circuit connected to external fault terminal or cause of external fault input. Operating method when the frequency command is lost No frequency command is applied to V1 and I. → C heck the wiring of V1 and I and frequency reference level. Remote keypad communication error Communication error between drive keypad and remote keypad. → C heck for connection of communication line and connector. - EEP: Parameter save error - HWT: Hardware fault - Err: Communication Error - COM: Keypad error → Contact your LSIS sales distributor. External fault B contact input Drive Starvert iG5A Series 43 •For your safety, please read user's manual thoroughly before operating. •Contact the nearest authorized service facility for examination, repair, or adjustment. Safety Instructions •Please contact a qualified service technician when you need maintenance. Do not disassemble or repair by yourself! •Any maintenance and inspection shall be performed by the personnel having expertise concerned. © 2005.5 LSIS Co.,Ltd. All rights reserved. ■HEAD OFFICE LS Tower, 127, LS-ro, Dongan-gu, Anyang-si, Gyeonggi-do, Korea ■EMEA +82-2-2034-4901 / [email protected] ■Asia Pacific / Americas +82-2-2034-4620 / [email protected] Overseas Branches ● ● ● ● LSIS(Wuxi) Co., Ltd._Wuxi, China No. 1, Lexing Road, Wuxi National High &New Tech Industrial Development Area, Wuxi214028, Jiangsu, P.T.China Tel : 86-510-8534-6666-8005 / Fax : 86-510-8534-4078 ● ● ● LS Hukai Electric(Hubei) Co., Ltd._ Hubei, China 1st. Floor, Tupolevlaan 48, 1119NZ,Schiphol-Rijk, The Netherlands Tel : 31-20-654-1420 / Fax : 31-20-654-1429 ● LSIS Japan Co., Ltd._Tokyo, Japan Tokyo Club Building 13F, 2-6, Kasumigaseki 3-chome, Chiyoda-ku, Tokyo, 100-0013 Tel : 81-3-6268-8241 / Fax : 81-3-6268-8240 ● ● LSIS USA Inc._ Chicago, U.S.A. 2000 Millbrook Drive, Lincolnshire, Chicago, IL 60069, United States Tel : 847-941-8240 / Fax : 847-941-8259 Specifications in this catalog are subject to change without notice due to continuous product development and improvement. 2015. 01 LSIS Chengdu Office, China Room1710, 17/F Huamin Empire Plaza, NO.1 Fuxin Road, Chengdu, P.R. China Tel : 86-28-8670-3200 / Fax : 86-28-8670-3203 ● LSIS ShenYang Office, China Room 803, Hongyuan Building, 52 South Nanjing Road, Heping District, Shenyang, P.R. China Tel : 86-24-2321-9050 / Fax : 86-24-8386-7210 ● LSIS Europe B.V._Netherlands LSIS Qingdao Office, China Room 2001, Galaxy Building, 29 ShanDong Road, ShiNan District, QingDao, ShanDong, P.R. China Tel : 86-532-8501-6058 / Fax : 86-532-8501-6057 Nguyen Khe, Dong Anh, Hanoi, Vietnam Tel : 84-4-6275-8055 / Fax : 84-4-3882-0220 LOB 19-205, JAFZA View Tower, Jebel Ali Free Zone, Dubai, United Arab Emirates Tel : 971-4-886-5360 / Fax : 971-4-886-5361 ● ● ● LSIS(ME) FZE_Dubai, U.A.E. LSIS Guangzhou Office, China Room 1818-1820, Xinyuan Building,NO.898 Tianhe North Road, Tianhe District, Guangzhou, P.R China Tel : 86-20-8326-6784 / Fax : 86-20-8326-6287 No. 100, Tanjiahe Road, Dianjun District, Yichang City, Hubei Province, 443004, China Tel : 86-717-667-7339 / Fax : 86-717-667-7559 LS-VINA Industrial Systems Co., Ltd._Hanoi, Vietnam LSIS Beijing Office, China Room 2306, Building B Landgent Center, No.24 Middle Road, East 3rd Ring Road, Chaoyang District, Beijing, P.R. China Tel : 86-10-5761-3127 / Fax : 86-10-5761-3128 LSIS(Dalian) Co., Ltd._Dalian, China No. 15, Liaohexi 3-Road, Economic and Technical Development Zone, Dalian 116600, China Tel : 86-411-8730-7510 / Fax : 86-411-8730-7560 LSIS Shanghai Office, China 32nd Floor, International Corporate City, No.3000 NorthZhongshan Road, Putuo District, Shanghai, China, 200063 Tel : 86-21-5237-9977 / Fax : 86-21-5237-7189 ● Overseas Subsidiaries www.lsis.com LSIS Jinan Office, China Room 317, Chuangzhan Center, No. 201, Shanda Road, Lixia District, Jinan, Shandong, P. R. China Tel : 86-531-8699-7826 / Fax : 86-531-8697-7628 LSIS Co., Ltd. Tokyo Office, Japan Tokyo Club Building 13F, 2-6, Kasumigaseki 3-chome, Chiyoda-ku, Tokyo, 100-0013 Tel : 81-3-6268-8241 / Fax : 81-3-6268-8240 ● LSIS Co., Ltd. Rep. Office, Vietnam Gema Dept Tower 18F, 6 Le Thanh Ton, District 1, HCM, Vietnam Tel : 84-8-3823-7890 ● LSIS Detroit Office, U.S.A. 5700 Crooks Rd, Suite 211, Troy, MI 48098, USA Tel : 1-248-792-2637~8 / Fax : 1-248-792-2642 ● LSIS Co., Ltd. India Office, India 109 First Floor, Park Central, Sector-30, Gurgaon- 122 002, Haryana, India Tel : 91-1244-930-077 / Fax : 91-1244-930-066 ● LSIS Moscow Office, Russia 123610, Krasnopresnenskaya, nab., 12, building 1, office №1005, Moscow, Russia Tel : 7-495-258-1466/1467 / Fax : 7-495-258-1466/1467 ● LSIS U.K. Office, United Kingdom G17 Bedford I-Lab, Stannard Way, Priory Business Park, Bedford, MK44 3RZ, U.K. Tel : 44-012-3483-4774 / Fax : 44-012-3483-4775 STARVERT iG5A (E) 2005. 05/(22) 2014. 06 Printed in Korea Pacomkorea