Download User Manual
Transcript
4.7. Inclination sensor An inclination sensor on the control board of the NIR120 M drying module watches the operating position of the module (default configuration horizontal alignment). If the positional deviates more than ~10° from the horizontal, the module will be locked. The status LED turns red and the push button status LED will blink red. To unlock put the device in the operating position and push the push button (both status LEDs will turn green). Note for NIR120 M2, NIR120 M3, NIR120 M4: These models can be configured via USB. Option to be configured: • Operating position • Tolerance of inclination angle Call +1 262-790-9100 (US) or +49-8061-395-0 (GER) for detailed information. Table 8: meanings of status LED Inclination sensor Status Meaning Blinking red, fast Signal from sensor is invalid (e.g. not calibrated) Red Out of operating position, module ready Green In operating position, module is ready or running Version 3.0 Page 21 of 35