Download GAMOS
Transcript
90 CHAPTER 8. SCORING parameter is set to TRUE those steps with step length zero will not be taken into account. – GmG4PSCellCharge This class scores the total charge of particles which have stopped or have been created in the volume, i.e. the tracks that enter count as +1 and the tracks that exit count as -1. – GmG4PSTrackCounter This class scores the number of tracks in a cell. • for Event Biasing Scoring for event biasing is a very specific use case whereby particle weights and fluxes through importance cells are required. The goals of the scoring technique are to: – appraise particle quantities related to special regions or surfaces, – be applicable to all ”cells” (physical volumes or replicas) of a given geometry, – be customizable. A number of scorers have been created for this specific application: – GmG4PSNofCollision This scorer records the number of collisions that occur within a scored volume/cell. – GmG4PSPopulation This scores the number of tracks within in a given cell per event. A particle weight is not applied by default. – GmG4PSTermination This scores the number of tracks that are terminated in a given cell per event. A particle weight is not applied by default. 8.2 Filter classes See section on Filters and classifiers. 8.3 Scorer printers A scorer printers serves to select the format of the output of a scorer. These classes are unique to GAMOS, as Geant4 does not provide this functionality. As mentioned above, several printers can be associated to the same scorer. The general use printer scorers currently in GAMOS are the following: • GmPSPrinterDefault Prints in the standard output the summary of scoring in the following format: