Now that you have set the format to require acknowledgement of the message, the
Acknowledgement notification bit field displays the address location of the
acknowledge-notification bit, as shown in Figure 2-16. This location can be used in the user
program to take an action when the user acknowledges the message on the TD 200. The
TD 200 sets this bit to 1 when the message is acknowledged. The user program is
responsible for resetting the acknowledge-notification bit to 0 if it is used within the program.
Click the “Finish” button to exit the TD 200 Configuration Wizard.
TD 200 Configuration Wizard
You have asked to configure 3 message(s). Define your message by
placing your highest priority message first.
Message 3 of 3
5
10
15
A C K N O W L E D G E
25
B Y
P R E S S
INS
Note: The address of
the acknowledgenotification bit is
displayed.
Embedded Data...
20
M E S S A G E
30
35
I N G
E N T E R
40
Message beginning address:
VB80
Message enabled bit:
V12.6
Acknowledgement notification bit:
V78.1
<Previous Message
< Prev
Next Message >
Finish
Cancel
Figure 2-16 Wizard: Message Requires Acknowledgement
2-16