KAM’98 Commands
Command Reference
software flow control set this parameter to the character the computer will send
to stop data flow.
See also: start, xflow, xoff, xon
STREAMCA
{ON | OFF}
default OFF
When receiving packets addressed only to you (MONITOR OFF and/or MCON
OFF), setting this command ON will enable the display of the callsign of the connected-to station following the stream identifier of the connection (controlled by
STREAMEV). This is especially useful when operating with multiple connections allowed.
See also: mcon, monitor, streamev
STREAMEV
{ON | OFF}
default OFF
When OFF, the stream indicator is displayed only when a change in streams occurs. When ON, the stream indicator will be displayed with every incoming
packet. This command takes effect only when receiving those packets addressed
to you and MCON is OFF.
See also: mcon, monitor, streamca, streamsw
STREAMSW
n
(n = $00 - $FF)
default $7C (|)
This command selects the character to be used to signify that a new “stream” or
connection channel is being addressed. To change streams you must type this
streamswitch character followed immediately by the stream designator. The
stream designator is an alphabetic character A through Z, or a through z, limited
by the value of MAXUSERS.
KAM’98 v 8.3
309
User’s Guide