13.4 Application warning messages When the highest bit of the warning message is set, an “Application warning message” is present. The application warning messages are bit-encoded as per the following pattern via parameter Application warnings 274. Parameter Application warnings 273 indicates the warnings as plain text in the control panel and the VPLus PC control software. Use parameter Application warnings 274 in order to read the warning messages via Field Bus. Bit no. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Warning code 0x0001 0x0002 0x0004 0x0008 0x0010 0x0020 0x0040 0x0080 0x0100 0x0200 0x0400 0x0800 0x1000 0x2000 0x4000 0x8000 Application warning messages Description BELT SW-LIM CW SW-LIM CCW HW-LIM CW HW-LIM CCW CONT ENC User 1 User 2 (reserved) (reserved) (reserved) (reserved) (reserved) (reserved) (reserved) - V-belt – SW limit switch clockwise – SW limit switch anticlockwise – HW limit switch clockwise – HW limit switch anticlockwise – contouring error – Warning Absolute encoder – User Warning 1 – User Warning 2 For details on the warnings, refer to the frequency inverter Operating Instructions and the “Positioning” application manual. The Warning Bit 6 “Absolute encoder” can be read out via Parameter 1274 in VPlus or 1273 via field bus. The Absolute encoder warnings are described in detail in the Extension manual EM-ABS-01. 130 CM-PROFINET 10/13