Prewarming
The Prewarming function of the printer will be checked in this test. Afterwards the printer
should display the “PREWARMING:” status.
Pos: 61.98 /Bedienungsanleitungen/Geräte spezifisch/Drucker/Menüpunkte Drucker/Ü3/Ü4/Ü3_3236_PEN Board @ 1\mod_1255684373658_912.doc @ 6663 @
PEN Board
This test will check the circuit (PEN) boards that are integrated in the print units. The test
will be performed with all circuit boards of the printer.
Authorised service personal can use the values of this test for service purposes.
Test
AMB.TEMP
Note
The measured temperature close to the printhead
nozzles in degree Celsius °C
REF.RES[h]
“Reference Resistor” – reference value
TSR [Hex]
„Thermal Sense Resistor“ - resistance value inside the
printhead
Pos: 61.99 /Bedienungsanleitungen/Geräte spezifisch/Drucker/Menüpunkte Drucker/Ü3/Ü4/Ü3_3241_LED/ Beeper @ 0\mod_1254916802136_912.doc @ 5103 @
LED/Beeper
Here you can check if all the LEDs of the display and the beeper work correctly. When
performing this test the printer will run through the following cycle:
ALL LED's OFF
LED ONLINE ON
LED OFFLINE ON
LED WARNING ON
LED ERROR ON
BEEPER ON (you will hear a sound for two seconds)
Pos: 61.100 /Bedienungsanleitungen/Geräte spezifisch/Drucker/Menüpunkte Drucker/Ü2/Ü2_3300_CONFIGURAT._INFO @ 0\mod_1254837071173_912.doc @ 4621 @
User Manual Version 3.1