Download APT-6S / APT-6SB

Transcript
APT-6S / APT-6SB
SAFETY PRECAUTION This manual uses the following symbols to ensure safe operation of this timer.
WEEKLY PROGRAMMABLE TIMER
User's Manual
Warnings are indicated when mishandling this controller might result in death or serious injury
to user.
Cautions are indicated when mishandling this controller might result in minor injury to the user,
or only physical damage to the timer.
WARNING
CAUTION
WARNING
RESTRICTIONS ON USE
When using this product in applications
that require particular safety or when
using this product in important facilities,
please pay attention to the safety of the
overall system and equipment. Install failsafe mechanisms, perform redundancy
checks and periodic inspections and
adopt other appropriate safety measures
when it is necessary.
ΘNote this incorrect wiring of this controller can damage it and lead to other hazards. Make sure the controller has
been correctly wired before turning the power ON.
ΘBefore wiring, or removing / mounting the controller, be sure to turn the power OFF. Failure to do so might cause
electric shock.
ΘDo not touch electrically charged parts such as the power terminals. Doing so might cause electric shock.
ΘDo not disassemble the controller. Doing so might cause electric shock or faulty operation.
CAUTION
ΘUse the controller within the operating ranges recommended in the specification (temperature, humidity, voltage,
shock, mounting direction, atmosphere and etc.). Failure to do so might cause fire or faulty operation.
ΘFirmly tighten the terminal screws. Insufficient tightening of terminal screws might cause electric shock or fire.
SPECIFICATION
BUTTON and SWITCH FUNCTIONS
Operating voltage
AC/DC : 12 ~ 48V / AC/DC : 100 ~ 240V
Allowable operating
voltage range
85 ~ 110% of rated operating voltage
Rated frequency
50 / 60 Hz
ΘCLOCK : Current time setting
ΘON
Contact rating
240VAC 7A(N.O.), 240VAC 5A(N.C.) Resistive load
Θʳ DAY
: Weekday setting
ΘAUTO : Output contact is controlled by
Indicator operating
POWER - Red / RELAY ON - Green
ΘʳʳHR
: Hour setting
Θʳ MIN
: Minute setting
Θ
Power consumption
Approx. 3.3VA
Life
Mechanical : 5,000,000 times / Electrical : 100,000 times
Ambient temperature -10 ~ +50 °C
Ambient humidity
MAX 85% RH
Weight
Approx. 170g
SET
: Porgram setting (ON/OFF) ΘOFF
program setting
ΘCLEAR : Clear setting
Θ RESET : Program reset
OPERATING FLOWCHART
When a time switch and load
power supply are the same.
N Type
CLOCK
DAY
CLOCK
SU MO TU WE TH FR SA
N Type
P ROGRA MM A B L E TIME R
: Output contact is enabled
ϡWhen switch to Auto mode from ON or OFF,
Γoutput contact will be kept in the previous
Γmode. Than, output contact will be controlled
Γby program setting.
CONNECTION
When a time switch and load
power supply are separate.
: Output contact is disabled
P R OGR A MMA B LE TI ME R
HR
CLOCK
TU
SET WEEKDAY
MIN
TU
SET HOUR
SET MINUTE
SET
CURRENT TIME SETTING
SET
DAY
CLOCK
HR
MIN
SET
DAY
AUTO
CLEAR OFF
CLOCK
ON
HR
MIN
AUTO
ON
CLEAR OFF
SET
RESET
ON
GREEN
OFF
RED
APT - 6S
PROGRAM SETTING
CLOCK
DAY
HR
MIN
CLEAR
RESET
ON
GREEN
OFF
RED
APT - 6S
ON OFF
SE T
SET PROGRAM NUMBER
LOAD
ON
SU MO TU WE TH FR SA
SE T
SET WEEKDAY
ON
MO
SE T
ON
SET HOUR
MO
SE T
SET MINUTE
LOAD
ON
MO
SE T
PROGRAM ENABLE OR DISABLEϡ
ϡThe pervious setting will be
shown when press
CLEAR
once again.
CONVERT Y TYPE (Flush Mounting) TO N TYPE (Surface Mounting)
BATTERY CHANGE
ᢲ
ᢳ
ᢲ
ᢳ
ᢴ
Lithium battery
CR2032
+
3 VOLTS
CONVERT N TYPE (Surface Mounting) TO Y TYPE (Flush Mounting)
ᢲ
ᢳ
ᢴ
ANLY ELECTRONICS CO., LTD.
http://www.anly.com.tw
ᢵ
M-APT6-D-B