Download B-SA4TP SERIES
Transcript
2.PRINTER SETUP ENGLISH VERSION EO1-33048 2.11 Threshold Setting 2.11 Threshold Setting (Cont.) The Parameter Fine Adjustment Mode contains sub menus for adjusting a print start position, cut/strip position, print tone, etc., and setting a threshold. For details, refer to Section 2.10 Print Position and Print Tone Fine Adjustment. Each time the [PAUSE] key is pressed, the sub menus are displayed sequentially. (3) While “<3>ADJUST SET.” is displayed, press the [PAUSE] key until the target sensor type is displayed. <3>ADJUST SET THRESHOLD<R>1.0V Black Mark Sensor [PAUSE] <3>ADJUST SET THRESHOLD<T>1.4V Feed Gap Sensor (4) Set a threshold voltage (calculated in Sensor Adjustment Menu) by using the [FEED] or [RESTART] key, as shown below. Threshold voltage = Midpoint between voltage at a print area and voltage at a gap/black mark Feed Gap Sensor Black Mark Sensor NOTE: Pressing the [FEED] key one time causes a –0.1V change, up to 0.0V. Pressing the [RESTART] key one time causes a +0.1V change, up to +4.0V. THRESHOLD<T>4.0V THRESHOLD<R>4.0V THRESHOLD<R>3.9V [RESTART] THRESHOLD<T>3.8V THRESHOLD<R>3.8V THRESHOLD<R>0.1V THRESHOLD<R>0.0V THRESHOLD<T>3.9V [FEED] THRESHOLD<T>0.1V THRESHOLD<T>0.0V (5) After choosing a threshold voltage, press the [PAUSE] key. (6) To check for a proper operation, issue the pre-printed media in online. If an error still occurs even after a manual threshold setting, change the threshold voltage a little, and retry. E2-65